National Repository of Grey Literature 14 records found  1 - 10next  jump to record: Search took 0.00 seconds. 
Evaluation of gas flow in the scintillation detector at different profiles and sizes of holes in the screens that have shaped the network
Truhlář, Michal ; Špinka, Jiří (referee) ; Maxa, Jiří (advisor)
This work deals with the flow of gas in the scintillation detector. Thesis describes the function of an electron microscope, the composition, distribution and development of microscopes from the earliest to modern. The work also includes familiarization with SolidWorks 3D modeling in which is the electron microscope modeled and Cosmos FloWorks in which they are carried out simulations of gas flow. The paper is focused on the flow of gas in various shapes of the screen and various pressures in chamber of specimen. The results of the analysis of both apertures variants are compared with the request to minimize the pressures in the trajectory of the secondary electrons of well as in the chamber of specimen.
Comparison of flow conditions in the gas detector used in the aperture and screen
Hubáček, Jiří ; Špinka, Jiří (referee) ; Maxa, Jiří (advisor)
The first part of the thesis deals with electron microscopy and physical model fluid flow. In the next part, a three-dimensional model is created in programme SolidWorks. It is the model of scintilating detector with aperture or screen with three hundred little apertures. These models are submitted to analysis focusing on investigation of the gas flow at different pressure in chamber of specimen ESEM using Cosmos FloWorks system. The results of the analysis of both apertures variants are compared with the request to minimize the pressure in the trajectory of the secondary electrons as well as in the chamber of specimen.
Placement Optimization of Projector Lens
Bezděk, Matěj ; Važík, Jiří (referee) ; Novotný, Pavel (advisor)
This diploma thesis deals with the creation of engineering design of holder of projector lens. The thesis is created in cooperation with department of development in Varroc Lighting Systems, s.r.o. Initial part provides a brief description of the development of lighting technology used in car´s headlamps. The following part describes solutions currently used in clamping the lens in holder. The main part of the thesis focuses on the design of holder of projector lens itself. Projector lenses testing provide critical values of cohesive failure of the lens material, which cannot be exceed during the process of lens fitting and its subsequent clamping. In the final part the engineering design is verified and optimized using finite element analysis.
Construction scintillation detector with one aperture for environmental scanning electron microscope
Přichystal, Vít ; Vyroubal, Petr (referee) ; Maxa, Jiří (advisor)
The thesis is focused on the design of a scintillation detector with one screen for environmental scanning electron microscope. At the beginning of the work is an introduction to microscopy. Further work is focused on the description of ESEM microscope and a scintillation detector. The following chapter is devoted to the dynamics of flow. They list the types of flow and mathematical description of equations. The next chapter is about using the software and the way of solution of flow. In the following chapter describes a proposal of the diaphragm and extraction method of the detector area. They are described some of type aperture. The last chapter is the conclusion, where the work is summarized.
Problems of the mirror shutter in the LED module of the headlight
Ettler, Jan ; Hlaváček, Martin (referee) ; Kalivoda, Milan (advisor)
This bachelor thesis deals with methods of attaching the mirror shutter in LED modules in headlamps. The aim is to compare three methods of attachment which are used in one of the platform variants. The following are the methods of attachment, followed by the description of the light sources and functions of the LED modules; they are: riveting, hot stamping and fixation with clips. Risk associated with the assembly of mirror shutter into the light source are analysed via FMEA analysis, including also measures and actions for risk reduction – implementation of lighting of produced light sources in a special jig in the light laboratory. Vibrations tests were carried out to find out the influence of vibration on the mirror shutter in LED modules in the traffic. The tests revealed that even if the clip is incorrectly fixed (not attached to the end position) it does not affect the functionality of the module.
Using Computer Aided Engineering for analyse the detector
Vyroubal, Petr ; Polsterová, Helena (referee) ; Maxa, Jiří (advisor)
This master's thesis deals with influence of the shape comparison of convergent and Laval nozzles in the secondary electron detector shutters to the resulting pressure and gas flow in the secondary electron detector for environmental scaning electron mictoscope. To the detector analysis are used Computer Aided Engineering systems CAD and CAE, SolidWorks and SolidWorks Flow Simulation.
Evaluation of Gas Flow at the Proposed Shapes of Scintillation Detector Aperture Sieves
Matloch, Roman ; Špinka, Jiří (referee) ; Maxa, Jiří (advisor)
This work describes briefly electron microscopy issue and physical model of fluid flow. Then the simplified three-dimensional model of scintillation detector will be created in SolidWorks system for 3D cubical models. The gas flow behind the screening in this 3D model will be analyzed and compared by method of finite cube method in SolidWorks Flow Simulation system. This screening will be analyzed in several variants: the screening with 0.6 mm opening and the screening with net-like openings. The results of analyses will be compared according to the requirements. The appropriate shapes from the analyzed parts will be practically measured.
Problems of the mirror shutter in the LED module of the headlight
Ettler, Jan ; Hlaváček, Martin (referee) ; Kalivoda, Milan (advisor)
This bachelor thesis deals with methods of attaching the mirror shutter in LED modules in headlamps. The aim is to compare three methods of attachment which are used in one of the platform variants. The following are the methods of attachment, followed by the description of the light sources and functions of the LED modules; they are: riveting, hot stamping and fixation with clips. Risk associated with the assembly of mirror shutter into the light source are analysed via FMEA analysis, including also measures and actions for risk reduction – implementation of lighting of produced light sources in a special jig in the light laboratory. Vibrations tests were carried out to find out the influence of vibration on the mirror shutter in LED modules in the traffic. The tests revealed that even if the clip is incorrectly fixed (not attached to the end position) it does not affect the functionality of the module.
Evaluation of Gas Flow at the Proposed Shapes of Scintillation Detector Aperture Sieves
Matloch, Roman ; Špinka, Jiří (referee) ; Maxa, Jiří (advisor)
This work describes briefly electron microscopy issue and physical model of fluid flow. Then the simplified three-dimensional model of scintillation detector will be created in SolidWorks system for 3D cubical models. The gas flow behind the screening in this 3D model will be analyzed and compared by method of finite cube method in SolidWorks Flow Simulation system. This screening will be analyzed in several variants: the screening with 0.6 mm opening and the screening with net-like openings. The results of analyses will be compared according to the requirements. The appropriate shapes from the analyzed parts will be practically measured.
Placement Optimization of Projector Lens
Bezděk, Matěj ; Važík, Jiří (referee) ; Novotný, Pavel (advisor)
This diploma thesis deals with the creation of engineering design of holder of projector lens. The thesis is created in cooperation with department of development in Varroc Lighting Systems, s.r.o. Initial part provides a brief description of the development of lighting technology used in car´s headlamps. The following part describes solutions currently used in clamping the lens in holder. The main part of the thesis focuses on the design of holder of projector lens itself. Projector lenses testing provide critical values of cohesive failure of the lens material, which cannot be exceed during the process of lens fitting and its subsequent clamping. In the final part the engineering design is verified and optimized using finite element analysis.

National Repository of Grey Literature : 14 records found   1 - 10next  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.