National Repository of Grey Literature 6 records found  Search took 0.01 seconds. 
Calibration management system of measuring machine (CMM)
Lysý, Zbyněk ; Pernikář, Jiří (referee) ; Koška, Petr (advisor)
This diploma thesis with title of „Management of Coordinate Measuring Machine Calibration“ aimed to develop detailed analysis of uncertainties when deploying 3D coordinate measuring machine MicroVu Excel in practice. The analysis was supported by an example of measuring uncertainty calculation. This thesis also discusses the integration of automatic assessment of uncertainties into programming equipment; and creation of methodical calibration process for this kind of machine.
Calibration of GOM ATOS optical coordinate measuring machines
Košťák, Ondřej ; Jankových, Róbert (referee) ; Harčarík, Matej (advisor)
This master’s thesis contains the basic division of 3D methods which are used for reconstruction of measured objects. Furthermore the types of structured light patterns used for 3D triangulation. It also contains a description of the construction and functions of GOM ATOS and TRITOP machines. Primarily the thesis deals with the calibration of these machines, the design of suitable materials standard of size and the internal calibration methodology used by ŠKODA AUTO a.s. The text also includes verification of the proposed calibration procedure in practice, proposal for determination of calibration uncertainties and recommendations for practice.
Process Calibrator M143 - Climatic Testing
Dojava, Václav ; Bartoň, Jan (referee) ; Havlíková, Marie (advisor)
Subject of the bachelor thesis are the climatic testing of the M143 calibrator. Theoretical section of the thesis is concerned with the analysis and description of the norms used during climatic tests of electronic devices. Thesis then continues by describing properties and functions of the M143 calibrator and the Caliber programme, which is performing automated measurement during the climatic tests, on the basis of the designed calibration procedure. Practical section of the thesis describes the designed testing points and climatic conditions, which are adjusted during the testing. In this section the testing points are implemented to the Caliber programme. Last section contains the analysis and evaluation of the measured data gained during the climatic testing. From these measured data, we are to determine, whether the M143 calibrator is within the specifications stated by the manufacturer in different climatic conditions.
Calibration of GOM ATOS optical coordinate measuring machines
Košťák, Ondřej ; Jankových, Róbert (referee) ; Harčarík, Matej (advisor)
This master’s thesis contains the basic division of 3D methods which are used for reconstruction of measured objects. Furthermore the types of structured light patterns used for 3D triangulation. It also contains a description of the construction and functions of GOM ATOS and TRITOP machines. Primarily the thesis deals with the calibration of these machines, the design of suitable materials standard of size and the internal calibration methodology used by ŠKODA AUTO a.s. The text also includes verification of the proposed calibration procedure in practice, proposal for determination of calibration uncertainties and recommendations for practice.
Process Calibrator M143 - Climatic Testing
Dojava, Václav ; Bartoň, Jan (referee) ; Havlíková, Marie (advisor)
Subject of the bachelor thesis are the climatic testing of the M143 calibrator. Theoretical section of the thesis is concerned with the analysis and description of the norms used during climatic tests of electronic devices. Thesis then continues by describing properties and functions of the M143 calibrator and the Caliber programme, which is performing automated measurement during the climatic tests, on the basis of the designed calibration procedure. Practical section of the thesis describes the designed testing points and climatic conditions, which are adjusted during the testing. In this section the testing points are implemented to the Caliber programme. Last section contains the analysis and evaluation of the measured data gained during the climatic testing. From these measured data, we are to determine, whether the M143 calibrator is within the specifications stated by the manufacturer in different climatic conditions.
Calibration management system of measuring machine (CMM)
Lysý, Zbyněk ; Pernikář, Jiří (referee) ; Koška, Petr (advisor)
This diploma thesis with title of „Management of Coordinate Measuring Machine Calibration“ aimed to develop detailed analysis of uncertainties when deploying 3D coordinate measuring machine MicroVu Excel in practice. The analysis was supported by an example of measuring uncertainty calculation. This thesis also discusses the integration of automatic assessment of uncertainties into programming equipment; and creation of methodical calibration process for this kind of machine.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.