National Repository of Grey Literature 4 records found  Search took 0.00 seconds. 
Safety of automated industrial valves in operating conditions
Kryštof, Ondřej ; Trávníček, Petr (referee) ; Kotek, Luboš (advisor)
Choosing suitable and safe valve with accessories depends on general specifications for plant. Using valve for on/off, throttling, back-flow prevention, etc., pressure drop is related with Kv value or leakages from piping systems are main factors for properly valve selection. Valve have to resist chemicals and substances that may change the state, temperature and its fluctuation, pressure, corrosion and erosion. This properties determine pressure class, temperature resistance, connection into pipe and sealing material as gland packing, seats, seal between flange etc. This and other specification, listed in this thesis, can help determine suitable type of valve. This thesis deals construction design of valve and accessories as well. The last chapters are focused on calculation of safety valve and selection safe and appropriate control valve with accessories.
The assessment of advantages of construction of large hydroelectric power plants in the area of Cukrova bouda, district Sumperk
Knápek, Michal ; Kopřiva,, Miroslav (referee) ; Mastný, Petr (advisor)
The subject matter of the master´s thesis is, in particular, an evaluation of the advantageousness of the construction of a pumped-storage hydroelectric power station in the vicinity of Cukrová Bouda. In the master´s thesis introduction the utilisation of pumped-storage hydroelectric power stations in providing reserve power generation to the operator of a power transmission system is discussed. The thesis then focuses on a technical design solution where two alternatives are drawn up for which the nominal parameters of individual designs for a pumped-storage hydroelectric power station are specified. The following part deals with the impact of the structure and the plant’s subsequent operation on the environment. A further key part is the determination of investment and subsequent operating costs and an evaluation of the plant according to economic pointers. The final part of the master´s thesis contains a SWOT analysis and an assumed programme of works for the plant’s preparation and actual construction. The conclusion contains an overall evaluation.
Safety of automated industrial valves in operating conditions
Kryštof, Ondřej ; Trávníček, Petr (referee) ; Kotek, Luboš (advisor)
Choosing suitable and safe valve with accessories depends on general specifications for plant. Using valve for on/off, throttling, back-flow prevention, etc., pressure drop is related with Kv value or leakages from piping systems are main factors for properly valve selection. Valve have to resist chemicals and substances that may change the state, temperature and its fluctuation, pressure, corrosion and erosion. This properties determine pressure class, temperature resistance, connection into pipe and sealing material as gland packing, seats, seal between flange etc. This and other specification, listed in this thesis, can help determine suitable type of valve. This thesis deals construction design of valve and accessories as well. The last chapters are focused on calculation of safety valve and selection safe and appropriate control valve with accessories.
The assessment of advantages of construction of large hydroelectric power plants in the area of Cukrova bouda, district Sumperk
Knápek, Michal ; Kopřiva,, Miroslav (referee) ; Mastný, Petr (advisor)
The subject matter of the master´s thesis is, in particular, an evaluation of the advantageousness of the construction of a pumped-storage hydroelectric power station in the vicinity of Cukrová Bouda. In the master´s thesis introduction the utilisation of pumped-storage hydroelectric power stations in providing reserve power generation to the operator of a power transmission system is discussed. The thesis then focuses on a technical design solution where two alternatives are drawn up for which the nominal parameters of individual designs for a pumped-storage hydroelectric power station are specified. The following part deals with the impact of the structure and the plant’s subsequent operation on the environment. A further key part is the determination of investment and subsequent operating costs and an evaluation of the plant according to economic pointers. The final part of the master´s thesis contains a SWOT analysis and an assumed programme of works for the plant’s preparation and actual construction. The conclusion contains an overall evaluation.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.