National Repository of Grey Literature 36 records found  1 - 10nextend  jump to record: Search took 0.00 seconds. 
Design of a system for measuring the consumption and quality of electrical energy in the buildings of the BUT campus in Brno
Holotík, Zbyněk ; Bátora, Branislav (referee) ; Janík, Daniel (advisor)
This bachelor's thesis deals with the design of a secondary measurement solution for the consumption and quality of electrical energy in the buildings of the Faculty of Mechanical Engineering at BUT in Brno, so that this measurement is compatible with the BMS systém used at BUT. Secondary measurement will help the energy management of the fakulty and also the entire university. Furthermore, the work deals with the documentation and technical report for this proposal. The last point is the mapping of low voltage distributions in the FSI area.
Calculation and technical solutions earthing system of transformer substation 110/22 kV
Mašek, Jakub ; Dušek, Igor (referee) ; Bátora, Branislav (advisor)
Master's thesis deals with principles of design of earthing of a substation 110/22 kV. Specific requirements for safety have to be fulfilled when designing power installations exceeding 1kV. The aim of this paper is to design a new earthing system for reconstructed substation 110/22kV considering valid standards. Reconstruction of a property is always more or less complicated by new orders and regulations for construction. Earthing is a part of all electric equipment, therefore it is essential for the design engineer to consider a broad spectrum of requirements, even those seemingly not related to this subject, from legislative requirements to the study of reactions of a human body to electric current. The theoretical part of this work examines different approaches to earthing system's design, and analyzes the origins and earthing standards throughout history. The correctness in consideration of effects of the environment is an often neglected factor. Defining of all types of effects of the environment is a broad field, therefore this paper only summarizes the main principles. The practical part of this paper deals with the basic design of substation's earthing system and it's verification in respect of touch voltage and step voltage according to the Czech national standard ČSN 33 3201 (Power installations exceeding 1kV a.c.) and of company's energetics' standard PNE 33 0000-1 ed.4 (Protection against electric shock in distribution network and transmission system) required by the substation's distributor. This paper later quotes and takes into consideration the requirements of other standards, more or less related to listed documents, creating an interconnected body for design and testing the earthing system.
Design of a 22 kV network in the Lipno area after the integration of the new 110/22 kV transformer station
Žižlavský, Jakub ; Koudelka, Jan (referee) ; Ptáček, Michal (advisor)
This diploma thesis deals with the design of a new 110/22 kV substation in Horní Planá. The substation design addresses, for example, the issue of reducing the load of surrounding power lines from 110/22 kV substations, reducing the size of short-circuit ratios in the surrounding system, reliability and continuity of supply, etc. Furthermore, loads of individual outgoing feeders from the surrounding substations are analyzed, in case they will be connected to a new substation. Following this, the work also addresses the related new decay points of the lines, which are determined by calculation and simulation in the Grizzly program. The simulation results could be used to compare the current load status of individual lines and contribute to the assessment of the possible benefits of both the new substation and the implementation of other modern technologies for faster and more efficient measurement and handling during operating and fault conditions.
Evaluation of connection possibility of new power plant from voltage point of view.
Macháč, Petr ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
This thesis deals with load flow calculation of electrical network 110 kV before and after connection of power plant 100 MW to network node Prostějov. This grid can be supply from two substations 400/110 kV - load flow calculation is realized for two variants of supply - the first from substation Sokolnice and the second from substation Otrokovice. Result of this thesis is evaluation of voltage conditions and conductor overload.
Load flow analyses of reactive power in distribution system
Krátký, Michal ; Kašpírek,, Martn (referee) ; Topolánek, David (advisor)
This thesis is focused on issues with transmission of reactive power though the distribution line of E.ON area. The goal is to find out where and in what rate are overflows of reactive power and to project the correctional steps to minimize this overflow. In this solution, there were used data of dispatcher measurement, which were processed by created source code in Matlab. The processing was analyzed for final conclusion. There were discovered shortages in overflow of reactive power in transfer between distribution and transmission line and in unsuitably regulated capacity power factor in Planá power plant and wrong automatic regulation of turns in 440/110kV substation Dasný. The action to minimize overflows of reactive power was projected by decompensation reactor placed in T101 and T102 transformers in substation Tábor.
Reconstruction of a transformer station with a substation for auxiliary systems
Novický, Marek ; Wasserbauer, Vojtěch (referee) ; Jurák, Viktor (advisor)
The master thesis deals with the premises of the Staré Brno heating plant, where there are two 22 / 0,4 kV transformers used to supply the heating plant's auxiliary system. The thesis deals with theoretical areas related to the planned design. After theoretical section is following a detailed description of the recent state of HV and LV substations and transformers. The scope of work is the design of new transformers, HV substations and LV substations, central compensation. At the end of the thesis is discussed the economic side of transformers.
Study of the Possibility of Extention of 110 kV substation in TKV
Poledník, Petr ; Grym, Rudolf (referee) ; Orságová, Jaroslava (advisor)
This project are deal with the posibility of extention of 100 kV substation in TKV. What is important for project is restriction of conditions for realization. The aim for project is create individual possibilities of solutions and consequently their evaluation.
Evaluation of possibilities for connection of wind farm Drahany 45 MW to 110 kV network
Gregr, Tomáš ; Opat, Jaroslav (referee) ; Topolánek, David (advisor)
This Master's thesis is focused on connecting of new power sources into electrical network, particularly, the steady state and allowed voltage variation in network nodes, which occur in steady state before and after connection of a new power source into distribution network, with regard to valid legislation. The new power source in question is the new wind farm Drahany with active power of 45 MW, which should be connected into distribution network 110kV, operated by distribution company E.ON. The aim of this work is to find the most suitable connection point of a wind farm into distribution network, considering transmission capacity of individual electric lines and voltage variations in network nodes, as well as Drahany wind farm's investor's expenses on construction of a connection line to connection point and the distribution network's operator's expenses on modification of the connection point. Also, methods of calculating of electric networks in steady state are described in this paper, particularly, linear calculations, because these are needed for the calculations in E-vlivy program, in which the possible options of Drahany wind farm's connection into network 110 kV, in various places, were modeled. The description of the E-Vlivy program is also included in this paper. The E.ON company's materials form the basis for this Master's thesis, which will later serve as one of the documents needed for Drahany wind farm’s connection point evaluation into distribution network 110 kV.
Management of the energy transmission system polygon
Bohačík, Antonín ; Musil, Petr (referee) ; Blažek, Petr (advisor)
The diploma thesis is focused on the creation of a control interface for a polygon simulating the electrical distribution network of the Czech Republic, where communication between substations is realized by IEC 60870-5-104 protocol. The theoretical part of the thesis explains the basic principles, properties and possibilities of communication standards IEC 60870 and IEC 61850. The next part is focused on the actual implementation and subsequent implementation of the control interface, including the implementation of the IEC 61850-80-1 module for data transfer between the mentioned standards. The last part describes the created behavior scenarios or the analysis of communication itself.
Selected Parts of Construction-Technological Project of Substation 110 kV Ostava Hrabová
Škrobánková, Zuzana ; Bravenec, Roman (referee) ; Mohapl, Martin (advisor)
This thesis deals with construction and technological project of 110 kV substation in Ostrava Hrabová. Includes design mechanical assembly, time and financial plan, technological studies during the construction of the main building structure, schedule, project site equipment, budgets and other documents that are required to correct the construction.

National Repository of Grey Literature : 36 records found   1 - 10nextend  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.