National Repository of Grey Literature 4 records found  Search took 0.00 seconds. 
Testing of Distance Protection
Řehoř, Jiří ; Topolánek, David (referee) ; Orságová, Jaroslava (advisor)
The testing of distance protection in bachelor´s task is made a distinction between protection, requirements and relegation. This testing is also consisted in principle of function, describing terms of distance protection and comparing with time-current characteristics. The next step after short estimation was describing digital distance protection SIPROTEC 7SA511. The advantages are included in this estimation. The next part contains some configurations and connections with a test equipment in order to take control of measuring through the computer. The extended configurations are also comprised of two programms – DIGSY and TZO3. We had to make a suggestion of suitable methodics for measuring a time-current characteristic. We carried out three measurements where the test equipment was set to role of type TREND. A magnitude is generated at the output that is changed linearly in time with required rate (speed). We changed a current IX1 for our measurements that was undertaken with a rate of current rise. This process was given by a test equipment when the set values were constant. In the second measurement we modified a size of shift phase in the test equipment. In the third measurement we tried to set up different sizes of particular impedance characteristics (zone) inside of the distance protection where was set a neutral breaking time for the measured zone. On the contrary, the previous measurements had an absolute time.We have introduced evaluated results of measuring and observations in the end of this bachelor’s thesis.
Testing of Distance Protection
Holub, Martin ; Vaculík, Petr (referee) ; Orságová, Jaroslava (advisor)
Bachelor thesis Testing of Distance Protection introduces us to the issue of distance protection and its detailed principle. It deals with its individual elements and shows us different types of impedance characteristics of measuring elements. It describes a situation that occurs during a short circuit on a homogeneous line, then introduces us to a DC component compensation and discuss the effect of distance protection degrees. Among other things, it deals with the digital distance protections and settings of their characteristics. Finally the theoretical part evaluates advantages over other protections and advantages and disadvantages of distance protections themselves. Thesis will introduce the digital distance protection REL 511 from the company ABB and characterizes its settings, parameters and connection to the testing equipment OMICRON CMC 256plus, which is used to control the protection via personal computer. Description of the programs OMICRON Test Universe and CAP 540 and their settings follows. This section can serve as a manual for future operators of REL 511 protection. The work provides a suitable methodology for measuring the operating characteristics and uses this method in practice. Given the limited version of the OMICRON Test Universe, polygonal tripping characteristics are measured in the module "Distance" with the shot test. Evaluation of measurements is summarized at the end.
Testing of Distance Protection
Holub, Martin ; Vaculík, Petr (referee) ; Orságová, Jaroslava (advisor)
Bachelor thesis Testing of Distance Protection introduces us to the issue of distance protection and its detailed principle. It deals with its individual elements and shows us different types of impedance characteristics of measuring elements. It describes a situation that occurs during a short circuit on a homogeneous line, then introduces us to a DC component compensation and discuss the effect of distance protection degrees. Among other things, it deals with the digital distance protections and settings of their characteristics. Finally the theoretical part evaluates advantages over other protections and advantages and disadvantages of distance protections themselves. Thesis will introduce the digital distance protection REL 511 from the company ABB and characterizes its settings, parameters and connection to the testing equipment OMICRON CMC 256plus, which is used to control the protection via personal computer. Description of the programs OMICRON Test Universe and CAP 540 and their settings follows. This section can serve as a manual for future operators of REL 511 protection. The work provides a suitable methodology for measuring the operating characteristics and uses this method in practice. Given the limited version of the OMICRON Test Universe, polygonal tripping characteristics are measured in the module "Distance" with the shot test. Evaluation of measurements is summarized at the end.
Testing of Distance Protection
Řehoř, Jiří ; Topolánek, David (referee) ; Orságová, Jaroslava (advisor)
The testing of distance protection in bachelor´s task is made a distinction between protection, requirements and relegation. This testing is also consisted in principle of function, describing terms of distance protection and comparing with time-current characteristics. The next step after short estimation was describing digital distance protection SIPROTEC 7SA511. The advantages are included in this estimation. The next part contains some configurations and connections with a test equipment in order to take control of measuring through the computer. The extended configurations are also comprised of two programms – DIGSY and TZO3. We had to make a suggestion of suitable methodics for measuring a time-current characteristic. We carried out three measurements where the test equipment was set to role of type TREND. A magnitude is generated at the output that is changed linearly in time with required rate (speed). We changed a current IX1 for our measurements that was undertaken with a rate of current rise. This process was given by a test equipment when the set values were constant. In the second measurement we modified a size of shift phase in the test equipment. In the third measurement we tried to set up different sizes of particular impedance characteristics (zone) inside of the distance protection where was set a neutral breaking time for the measured zone. On the contrary, the previous measurements had an absolute time.We have introduced evaluated results of measuring and observations in the end of this bachelor’s thesis.