Národní úložiště šedé literatury Nalezeno 4 záznamů.  Hledání trvalo 0.00 vteřin. 
Image reconstruction from non-Cartesian k-space data acquired by ultra-short echo-time and fast MR imaging methods
Pšorn, Tomáš ; Latta,, Peter (oponent) ; Starčuk, Zenon (vedoucí práce)
The aim of this thesis is to handle theoretically the technique of MRI image reconstruction from non-Cartesian data such as radial, spiral, etc. Since later progress of this thesis will include actual measuring of non-Cartesian data, which is prone to the gradient infidelity, methods for measuring a performance of the gradient system will also be discussed. In practical part I will present the way the 4.7 T and 9.4~T MRI systems of the Institute of Scientific Instruments of the ASCR, v. v. i., works and use the existing pulse sequences to measure some model data.
Kompatibilita vybraných dentálních slitin s metodou vyšetření magnetickou rezonancí
Linetskiy, Igor ; Hubálková, Hana (vedoucí práce) ; Suchánek, Jakub (oponent) ; Dostálová, Taťjana (oponent)
Vyšetření magnetickou rezonancí (MR) je jednou z moderních a perspektivních metod medicínské vizualizace. Je ceněno pro absenci ionizujícího záření, neinvazivitu, získávání vysoce přesných zobrazení tvrdých a zejména měkkých tkání v libovolné rovině. Je metodou volby pro vyšetření centrální nervové soustavy. V poslední době se velmi často využívá v diagnostice onemocnění v maxilofaciální krajině. Hlavní slabinou MR je interakce magnetických polí s kovovými předměty přítomnými v těle člověka, její následkem může docházet k jejich ohřevu, pohybu a výskytu artefaktů MR obrazů. Vzhledem k tomu, že se v moderní stomatologii velmi často používají různé kovové konstrukce (fixní zubní náhrady, implantáty, dlahy, ortodontické aparáty aj.), otázka jejich kompatibility s MR prostředím je velmi aktuální. Cílem této práce bylo ověřit kompatibilitu dentálních slitin s prostředím MR, klasifikovat vybrané dentální slitiny dle stupně kompatibility s MR prostředím a stanovit rozsah jejich možného negativního vlivu na kvalitu MR vyšetření v oblasti hlavy a krku. Pro vyhledání dentálních kovů a slitin byl použit číselník VZP (Stomatologické výrobky), katalogy výrobců a distributorů dentálních slitin a nabídka zpracovávaných kovů a slitin v pražských zubních laboratořích. Jsou zde popsány metodiky stanovení magnetické...
Image reconstruction from non-Cartesian k-space data acquired by ultra-short echo-time and fast MR imaging methods
Pšorn, Tomáš ; Latta,, Peter (oponent) ; Starčuk, Zenon (vedoucí práce)
The aim of this thesis is to handle theoretically the technique of MRI image reconstruction from non-Cartesian data such as radial, spiral, etc. Since later progress of this thesis will include actual measuring of non-Cartesian data, which is prone to the gradient infidelity, methods for measuring a performance of the gradient system will also be discussed. In practical part I will present the way the 4.7 T and 9.4~T MRI systems of the Institute of Scientific Instruments of the ASCR, v. v. i., works and use the existing pulse sequences to measure some model data.
Scanning Probe Microscopy: Measuring on Hard Surfaces
Matějka, Milan ; Urbánek, Michal ; Kolařík, Vladimír
During a measurement by scanning probe microscopy (SPM) an image artifacts can appear in a measurement data. The source of image artifacts during an SPM measurement could be in parts of the SPM tool: mechanical system, piezoelectric crystal, scanner electronic. However, the main source of image artifact is the probe tip geometry and properties of the sample. For example, probe wearing, which occurs during the contact measurement on a sample with a hard surface, could result in heavy probe shape change, causing probe-related image artifacts. Measurement could appear problematic on a sample with periodical relief structure (e.g. gratings with sub 10 μm periodicity) prepared in hard materials (e.g. silicon), when the structure height is greater than about 500 nm. In this case, probe can easily get struck during the scanning, on the hard surface as well as at the high aspect ratio relief structure, causing image artifact thus reducing measurement quality.

Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.