Study of Generation, Trapping and Atomization of Hydride Forming Elements for Atomic Spectrometry
Furdíková, Zuzana ; Sommer, Lumír (oponent) ; Čelechovská, Olga (oponent) ; Řehůřková, Irena (oponent) ; Dočekalová, Hana (vedoucí práce)
Interference effects of co-generated hydrides of arsenic, antimony, bismuth and selenium on trapping behavior of selenium or antimony hydrides (analytes) within iridium modified, transversely heated graphite tube atomizer (THGA) was investigated. A twin-channel hydride generation system was used for independent separate generation and introduction of analyte and interferent hydrides, i.e. in simultaneous and/or sequential analyte-interferent and interferent-analyte mode of operation. Influence of the analyte and modifier mass, interferent amount, trapping temperature and composition of the gaseous phase was studied. A simple approach for elimination of mutual interference effects by modification of the gaseous phase with oxygen in substoichiometric ratio to chemically generated hydrogen is proposed and suppression of these interference effects is demonstrated. A hypothesis on mechanism of trapping and mutual interference effects is drawn.
Stanovení selenu metodou HG-AAS s prekoncentrací a atomizací v plazmovém výboji s dielektrickou bariérou
Duben, Ondřej ; Kratzer, Jan (vedoucí práce) ; Rychlovský, Petr (oponent)
Náplní této diplomové práce bylo optimalizovat podmínky atomizace hydridu selenu v novém plazmovém atomizátoru s dielektrickou bariérou (DBD) s detekcí pomocí atomové absorpční spektrometrie. Pro tento atomizátor byly následně určeny základní analytické charakteristiky, které byly porovnány s běžně používaným externě vyhřívaným křemenným atomizátorem, který byl v této práci nahrazen multiatomizátorem (MMQTA). Detekční limit dosažený v DBD atomizátoru (0,24 ng ml−1 Se) je jen mírně horší než v MMQTA (0,15 ng ml−1 Se). Odolnost DBD atomizátoru vůči interferencím je naopak lepší než v případě MMQTA. Rovněž byla studována prekoncentrace hydridu selenu v plazmovém atomizátoru s dielektrickou bariérou a bylo dosaženo prekoncentrační účinnosti 75 ± 5%. Mez detekce při použití doby prekoncentrace 300 s činila 0,012 ng m1−1 Se. Klíčová slova: atomová absorpční spektrometrie s generováním hydridů, dielektrický bariérový výboj, atomizace hydridu, prekoncentrace, selen
Study of Generation, Trapping and Atomization of Hydride Forming Elements for Atomic Spectrometry
Furdíková, Zuzana ; Sommer, Lumír (oponent) ; Čelechovská, Olga (oponent) ; Řehůřková, Irena (oponent) ; Dočekalová, Hana (vedoucí práce)
Interference effects of co-generated hydrides of arsenic, antimony, bismuth and selenium on trapping behavior of selenium or antimony hydrides (analytes) within iridium modified, transversely heated graphite tube atomizer (THGA) was investigated. A twin-channel hydride generation system was used for independent separate generation and introduction of analyte and interferent hydrides, i.e. in simultaneous and/or sequential analyte-interferent and interferent-analyte mode of operation. Influence of the analyte and modifier mass, interferent amount, trapping temperature and composition of the gaseous phase was studied. A simple approach for elimination of mutual interference effects by modification of the gaseous phase with oxygen in substoichiometric ratio to chemically generated hydrogen is proposed and suppression of these interference effects is demonstrated. A hypothesis on mechanism of trapping and mutual interference effects is drawn.
Záchyt hydridů As a Se na křemenném povrchu - krok směrem k in-situ prekoncentraci v křemenných atomizátorech s detekcí AAS
Kratzer, Jan ; Dědina, Jiří ; Rychlovský, P.
Práce popisuje optimalizaci podmínek prekoncentrace hydridů arsenu a selenu na křemenném povrchu. Pro tento účel byl navržen nový design aparatury sestávající z křemenného prekoncentračního zařízení integrovaného s křemenným multiatomizátorem.
Proč by měl použít analytický chemik ke stanovení AAS zakoncentrování hydridu na křemenném povrchu
Kratzer, Jan ; Dědina, Jiří ; Rychlovský, P.
V práci je prezentováno hodnocení extrémně jednoduché metody zakoncentrování antimonu a bismutu založené na novém experimentálním přístupu, in-situ záchytu stibinu a bismuthinu v zevně vyhřívaném křemenném atomizátoru.
Nový přístup k prekoncentraci antimonu: záchyt stibanu na křemenném povrchu s následným stanovením metodou AAS
Kratzer, Jan ; Dědina, Jiří ; Rychlovský, P.
Byla vyvinuta nová metoda stanovení stopových koncentrací antimonu, která umožňuje po 5minutové prekoncentraci stanovení vzorků s obsahem řádově v desítkách pg.ml-1.
Prekoncentrace antimonu na křemenném povrchu po generování stibanu
Kratzer, J. ; Dědina, Jiří ; Rychlovský, P.
Cílem této práce bylo bylo ověřit možnost použití záchytu na křemenném povrchu pro prekoncentraci antimonu před stanovením AAS