Národní úložiště šedé literatury Nalezeno 32 záznamů.  předchozí11 - 20dalšíkonec  přejít na záznam: Hledání trvalo 0.00 vteřin. 
Micro-electromembrane extraction across multiple aqueous and organic phases for selective pretreatment of raw biological samples
Kubáň, Pavel ; Boček, Petr ; Seip, K. F. ; Gjelstad, A. ; Pedersen-Bjergaard, S.
Micro-electromembrane extraction (μ-EME) across multiple aqueous and organic\nsolutions was developed for selective extractions of various analytes from untreated\nbiological samples. The novel approach requires μL volumes of samples and organic\nsolvents, which form consecutive immiscible plugs in a transparent polymeric capillary\nand the extraction process is accelerated by application of d.c. voltage. Number of the\nplugs, their composition, volume and sequence in the extraction capillary can be chosen\nspecifically for each particular application and high variability and selectivity of the\nextraction process can be achieved. In this contribution, we demonstrate suitability of\na five-phase μ-EME system for simultaneous extractions of cations and anions from\nurine and for selective extractions of basic analytes based on their acid-base strength\nfrom plasma.
Highly sensitive analysis of chlorophenols and sulfonamides in waters by electrophoretic focusion on inverse electromigration dispersion gradient with ESI-MS detection
Malá, Zdeňka ; Gebauer, Petr ; Boček, Petr
This work presents a new methodology for high-sensitivity analyses by capillary\nelectrophoresis (CE) with electrospray-ionization mass spectrometric (ESI-MS)\ndetection, based on electrophoretic focusing on an inverse electromigration dispersion\n(EMD) gradient. The technique is based on a robust electrolyte system providing a\ngradient of required properties, suitable for routine analyses of trace amounts of weak\nacids with pKa values between approx. 6.5 and 9. Examples analyses of several\nchlorophenols and sulfonamides are presented, with LODs around 3x10-9 M for spiked\ndrinking water without any sample pretreatment.
Demokufr R360
Balga, Ondřej ; Boček, Petr (oponent) ; Štohl, Radek (vedoucí práce)
Bakalářská práce se věnuje návrhu demonstrační úlohy mobilního řídicího systému R360 do kufru. Mobilní systém R360 je zde doplněn o snímače teploty, polohy a otáček a krokový motor. Návrh má předvést možnosti mobilního systému R360.
Novel microextraction techniques in pretreatment of complex samples
Kubáň, Pavel ; Pantůčková, Pavla ; Šlampová, Andrea ; Boček, Petr
Fundamental considerations and practical applications of various microextraction techniques for pretreatment of samples with complex matrices are summarized in this lecture. Special emphasis is devoted to electrically driven microextractions, such as electromembrane extraction across supported liquid membranes, their down-scaling to micro- and nano- format and their applications in capillary electrophoretic analyses of biological samples.
Capillary isotachophoresis with ESI-MS detection: Ultrahighly sensitve analysis of diclofenac and ibuprofen in waters
Malá, Zdeňka ; Gebauer, Petr ; Boček, Petr
This work shows that CE-MS can reach same sensitivity as HPLC-MS, when it is peformed in the ITP-MS mode. By combination of ITP-ESI-MS with an offline SPE preconcentration step and optimization of MS signal collection, LODs below 2x10-12 M can be reached, corresponding to of 0.6 ng/L of diclofenac (Dic) and 0.4 ng/L of ibuprofen (Ibu), compatible to that of SPE-HPLC-MS.
Polymer inclusion membranes open new way in practical use of in-line coupling of microextraction to CZE
Pantůčková, Pavla ; Kubáň, Pavel ; Boček, Petr
Polymer inclusion membranes (PIMs) have several important features, i.e., PIMs are dry and non-porous membranes, which can be prepared ahead of use and stored without noticeable deterioration in extraction performance. In-line coupling of microextractions across PIMs to commercial capillary zone electrophoresis (CZE) instrument has been demonstrated in this contribution. Purpose-made microextraction devices with PIMs were applied, which ensured complete automation of the entire analytical procedure. Practical 169 applicability of the hyphenated analytical method was demonstrated on direct extraction, injection, CZE separation and quantification of formate (the major metabolite in methanol poisoning) in clinical samples.
Considerations on electrolysis in electromembrane extraction of basic drugs
Šlampová, Andrea ; Kubáň, Pavel ; Boček, Petr
Electrolysis may significantly affect composition and pH values of non-optimized acceptor solutions and have fatal consequences on quantitative EME results for weak and medium strong analytes. Acceptor solutions consisting of high concentrations of weak acids have therefore been proposed as suitable operational solutions for electromembrane extraction (EME) of selected basic drugs. 500 mM formic acid efficiently eliminated the electrolytically produced OH– ions, offered constant pH and thus long-term EME performance and was easily compatible with subsequent analytical methods. Maximum EME recoveries ranged from 66 to 89% and were constant between 40 and 80 min of EME and no back-extraction of the analytes into donor solutions was observed.
Electrolysis in electromembrane extractions. Effects on extraction performance for substituted phenols
Šlampová, Andrea ; Kubáň, Pavel ; Boček, Petr
Electrolysis was shown to play a significant role in electromembrane extraction (EME) performance. Alkaline acceptors, prepared as 1 – 10 mM CsOH solutions, suffered from electrolytic reactions during EMEs of substituted phenols and their pH values decreased by more than 8 units after 40 min of EMEs at 50 V. As a consequence, serious deterioration of EME performance was observed for weak and medium-strong acidic phenols due to their compromised ionization and their subsequent back-extraction into organic phase and donor solution. Application of acceptor solutions consisting of high concentrations of weak bases (e.g. 500 mM ethanolamine) ensured similar initial pH conditions as for the alkali-metal hydroxide based solutions, moreover, significantly better tolerance to electrolysis-induced effects was obtained. Stable pH of acceptor solutions was achieved as well as an improved EME performance for all analytes over the entire extraction period.
Direct coupling of supported liquid membrane extractions to capillary electrophoresis. Sensitivity enhancement in analyses of untreated complex samples
Pantůčková, Pavla ; Kubáň, Pavel ; Boček, Petr
Extractions across supported liquid membrane (SLM) were in-line coupled to capillary electrophoresis (CE) commercial system for direct injection of basic drugs from raw complex samples. A micro-extraction unit was inserted into the CE system sampling device and ensured excellent sample clean-up and injections directly from the membrane surface. Transient isotachophoresis (t-ITP) combined with large electrokinetic injections of selectively extracted basic analytes increased the sensitivity of the analytical method up to 300-fold when compared with conventional hydrodynamic injections and capillary zone electrophoresis (CZE) of the basic analytes.
Theoretical principles of capillary isotachophoresis in moving boundary systems
Gebauer, Petr ; Malá, Zdeňka ; Boček, Petr
This contribution provides fundamental theoretical background of ITP in moving-boundary systems. It is based on the approximation of capillary ITP as a 1D process and the general condition of ITP migration, i.e., the existence of a self-sharpening boundary capable to form a stack of zones moving with equal velocities.

Národní úložiště šedé literatury : Nalezeno 32 záznamů.   předchozí11 - 20dalšíkonec  přejít na záznam:
Viz též: podobná jména autorů
6 Boček, Pavel
Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.