National Repository of Grey Literature 802 records found  beginprevious758 - 767nextend  jump to record: Search took 0.00 seconds. 
Comparison of HomePlug broadband systems and DS2 technology PLC
Horáček, Lukáš ; Zeman, Václav (referee) ; Mišurec, Jiří (advisor)
This thesis comparing broadband systems HomePlug and DS2 PLC technology (Power Line Communications). PLC is a technology for transmitting data over electrical power distribution network. The theoretical part consists of describing a system for broadband data communication over high-tension lines, the selection criteria, a description of DS2 and HomePlug (variants of chips, version, network architecture, elements). There are also described modulation techniques, interference, standards, standard ISO 50065 and access methods. The practical part consists of laboratory measurements with both systems. For the testing were used DS2 modems from the company Defidev and HomePlug modems from AirLive. These are then compared according to selected criteria.
Adaptive optimal controllers with principles of artificial intelligence
Samek, Martin ; Malounek, Petr (referee) ; Pivoňka, Petr (advisor)
Master’s thesis describes adaptive optimal controller design and it’s settings. Identification with principles of artificial intelligence and recursive least squares identification with exponential and directional forgetting are compared separately and as part of controller. Adaptive optimal controller is tested on physical model and compared with solidly adjusted PSD controller. Possibilities of implementation of adaptive optimal controller into programmable logic controller B&R are show and tested.
Internet Connection variants using present TV cable wiring
Lukáč, Michal ; Martinásek, Zdeněk (referee) ; Stančík, Peter (advisor)
This dissertation examines data transfers along the existing lines of cable TV. PLC equipment has been selected as the focus of this examination. The essay examines the question of Multicarrier modulation and focuses more specifically onto the problem of OFDM modulation, which is being used by the selected equipment. It further describes the process of integration of PLC equipment into the cable TV network, modifications of the CATV and the basic topology of the created data networks. The essay also offers a closer look onto a PLC modem and Head End from Corinex that have been used in the implementation of a data network in a selected rural settlement. The author has also raised the issue of the problems connected with cable wires connected with this particular type of data transfers and the solutions of some of the encountered problems. The characteristics of this network have then been measured during normal operation of the created network. Measurements have been carried out in order to determine the transfer speed on a physical and transfer level, the SNR of specific connections and the signal attenuation. The measurements have confirmed the suitability of the used PLC equipment for the purposes of data transfer along the cable TV lines as far as data speed and signal strength was concerned. A map of the particular cable TV lines and the PLC equipment has been included in the attachment.
Remote data acquisition over the power lines
Neuschl, Martin ; Koutný, Martin (referee) ; Mlýnek, Petr (advisor)
The subject of this paper is „remote data acquisition over the power lines“. The first part is engaged in characteristics of power lines. The other part considers PLC technology, its properties and usage. Base on disturbance and noise in power grid is chosen optimal modulation technique and error handling for PLC. The next part describes options of authentication. It has been designed secure way of authentication for data collection over power lines and attack-resistance is considered as well. Practical purpose is dedicated to simulations and noise measuring during communication of narrowband PLC modems. It deals with long-term power grid testing and its influence on transmission rate between PLC modems and also with the influence on primary parameters of power grid. Packets are investigated during communication as well.
Modelling of Power Line Communication for data transmission
Kadlček, Václav ; Mišurec, Jiří (referee) ; Mlýnek, Petr (advisor)
Thesis deals with problems PLC (Power Line Communication) communication. It is aimed at drawing up a suitable model for testing power network PLC communication. The reader is aware of at the beginning of work with the basic principles of PLC systems, distribution and use in communication networks. Another part of the work deals with different types of interference, which occur in power networks and ways to defend against such interference. For example, an appropriate choice of modulation and coding relevant. As a source of interference in the proposed model is used AWGN channel (Additive White Gaussian Noise). Conclusion of work is dedicated to design and build a model for PLC communication. There are three models designed with different OFDM technology. Models therefore vary between different levels of key mapping in OFDM (QPSK, 16-QAM, 64-QAM). It made a detailed description of a set of blocks that were used to build models. The behavior and functionality of the proposed models for broadband PLC communication was verified in the simulation program Matlab Simulink. Finally, it is shown the comparison and evaluation of results of each modulation.
Power-line data communication
Šádek, Michal ; Mlýnek, Petr (referee) ; Mišurec, Jiří (advisor)
This master's thesis describes a principle of the systems for data communication over powerline. The frequency we can divide to narrowband and broadband. Various modulatory techniques with their usage and access method technology according to norms are mentioned. Engineering constraints as are frequency subband and sources disturbance are mentioned. A conception laboratory net is designed, where are effected trial measurement in data communications for systems ModemTec, Homeplug AV a DS2. This demonstration of communication contains display communications spectrum of choice systems and their matching. To comparison is used synthetic created nets LISN (Line Impedance Stabilizing Network) in narrowband transmissions. Long - term metering of systems ModemTec is is effected in laboratory net VUT and in the working condition in Swiss extension companies Daetwyler Rubber where are produced robust rubbery production. System DS2 is measured in home network, where are supposes low disturbance and in industrial environment company Daetwyler Rubber. On the basis report information of phase quality recorder a powerline and measured rate of communication, it is evaluate an influence disturbance on a data transmission and response time. At the close are mentioned principles of usage this communication.
Network Voice Message Box
Dítě, Miroslav ; Sysel, Petr (referee) ; Zeman, Václav (advisor)
In this Master's thesis a power line communication is shortly described and the scheme of the communication system is realized. The communication device is called NVMB. This abbreviation means Network Voice Message Box. It should be used for transfer of the voice message via power line. It enables its recording, playback and sending. A process of the scheme design is created, functionality of the device is realized and reviewed in the main part of the Master's thesis. The other chapter of the thesis is devoted to the software communication system.
Control system for cleaning station CIP used for cleaning of milk processing equipment
Šindelář, Petr ; Slezák, Petr (referee) ; Pásek, Jan (advisor)
The thesis describes hardware and software of Control system for cleaning station CIP used for cleaning of milk processing equipment. The description of hardware contains definitions and number of PLC modules for PLC Simatic S7-300. The software part contains programs for PLC, SCADA software for WinCC flexible 2005 and the description of the computer's model.
Narroband PLC model
Sekot, Karel ; Krajsa, Ondřej (referee) ; Mišurec, Jiří (advisor)
This thesis is focused on data communication utilizing low-voltage power distribution lines (PLC). It describes interference in narrowband systems commonly used for remote data collecting, for example. Preamble deals with basic priciples of PLC (signal injecting) and describes the measuring workplace, its wiring and used tools. Following sections define different types and possible sources of interference, operation of the equipment in terms of EMC and other characteristics of the transmission path. The text also analyzes practical interference tests, identifies main parameters affecting data transmision and compares teoretical and practical conclusions.
A static power source control and monitoring via Ethernet
Rücker, Jan ; Šlezingr, Jan (referee) ; Drápela, Jiří (advisor)
This project deals with design and implementation of management and monitoring of static power source via ethernet. Description of individual objects and instalations which are located in static power source. Design and implementation of a system for access control of individual users.

National Repository of Grey Literature : 802 records found   beginprevious758 - 767nextend  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.