National Repository of Grey Literature 13 records found  previous11 - 13  jump to record: Search took 0.01 seconds. 
Current Transformers and Current Sensors Confrontation
Popek, Jiří ; Bok, Jaromír (referee) ; Topolánek, David (advisor)
Current transformers and current sensors are devices which are mostly used for current measurement in high voltage systems. This devices transform measured currents to range which are workable for measurement and protection devices. Current transformers have been using for current measurement since electric system was built. Current sensors are using for measurement after applying digital devices in their secondary circuits. Theoretical part includes fourth and fifth chapter. These chapters contain construction analysis and characteristic points for both devices. Practical part is in chapter six. This chapter consists results from laboratory measurement. Results are used for verification with theoretical part of the thesis. Accuracy class in nominal range and progress for measurement error in overcurrent range was verified for tested devices. Conclusion of this thesis comparing properties and summarises results from laboratory measurement.
Comparison of Instrument Transformer and Sensor Applications in Feeder Terminal REF 542plus
Hrycík, Tomáš ; Majer, Karol (referee) ; Orságová, Jaroslava (advisor)
The aim of this Master´s thesis is use of instrument transformers and sensors on field of industry protection. We will compare current and voltage transformers, current sensor – based on Rogowski coil, voltage sensor – based on voltage divider. By this measure devices, we can monitoring values of analog quantities in medium voltage switchgear. It is impossible to compare, measure and analyze without this measure devices. There is protection terminal REF542plus, which can compile this values. The REF542plus ability are measuring, monitoring, remote control and protection. First, we will discuss about theory of sensors and convential instrument transformers and analysis of analog signal. We will compare analog input channel on sensor´s analog module and transformer´s analog module. There are few differences between type of analog modules. For analog signal analysis are important frequency filters and Analog/ Digital Convertor (sigma-delta). We will describe functions and options of REF542plus. In practical part of this project, we will test protection functions of protection terminal. First, protection terminal will be connected to sensors. Second protection terminal will be connected to transformers. For testing we chose Earth-fault directional protection and differential protection. We will make only secondary tests. That´s mean, input analog quantities to REF542plus will be simulated by tester. In all we will verify quality of protection. We will focus on lower settings of protection and we will inject protection by low current. Objectives are testing of trip characteristics and measuring of trip time.
Design digital optical output
Kubáč, Stanislav ; Beneš, Petr (referee) ; Klusáček, Stanislav (advisor)
This work descibes general principles of measuring the alternating current and voltage using conventional and unconventional sensors.This work shows specific parmeters conected with principles of the measurement, advantages and disadvantages of individual measuring procedures, types of output signals, precisions, limitations, ways of power and so on. Part of the work is to find optimal measurement procedure, which can be aplicated to practical measuring of alternating currents and voltage. Main part of the work concerns the realisation of optimal method of measuring alternating current.