Národní úložiště šedé literatury Nalezeno 7 záznamů.  Hledání trvalo 0.00 vteřin. 
Determination of cadmium by chemical vapour generation coupled with atomic fluorescence spectrometry
Štádlerová, Barbora ; Sagapova, Linda ; Musil, Stanislav
Development of a methodology for determination of cadmium based on chemical vapour generation coupled with atomic fluorescence spectrometry.
Chemical vapor generation of cadmium for analytical atomic spectrometry
Sagapova, Linda ; Kodríková, Barbora ; Svoboda, Milan ; Musil, Stanislav ; Kratzer, Jan
Chemical vapor generation of cadmium volatile compounds was optimized in order to determine trace Cd concentrations by atomic absorption spectrometry (AAS). Several reaction modifiers based on inorganic salts and complexes of CrIII+, CoII+, TiIII+, TiIV+ were tested to improve analytical performance and generation efficiency.
Trapping of volatile cadmium species on gold surfaces for atomic absorption spectrometry
Sagapova, Linda ; Svoboda, Milan ; Matoušek, Tomáš ; Kratzer, Jan
Simple preconcentration step was developed for cadmium determination after chemical vapor generation prior to atomic absorption spectrometric detection. Chemical vapor generation of cadmium was performed in the presence of Cr3+/KCN as modifiers.
Optimalizace podmínek chemického generování a atomizace těkavých specií kadmia pro atomovou absorpční spektrometrii
Sagapova, Linda ; Kratzer, Jan (vedoucí práce) ; Marschner, Karel (oponent)
Cílem této diplomové práce byla optimalizace podmínek generování a atomizace těkavé formy kadmia pro stanovení jeho stopových koncentrací metodou generování těkavých sloučenin (VCG) s detekcí atomovou absorpční spektrometrií (AAS). Byly testovány tři různé konstrukce generátorů těkavých sloučenin. Jednalo se o konvenční hydridový generátor v uspořádání průtokové injekční analýzy (FIA), dávkový generátor a generátor těkavých sloučenin přechodných kovů. Účinnost generování Cd za optimálních podmínek v konvenčním generátoru ve FIA uspořádání dosahovala pouze 4 %. Odstranění kyslíku rozpuštěného v reagenciích vedlo ke zvýšení účinnosti generování Cd v tomto systému na 12 %. Nejvyšší účinnosti generování Cd (54 %) bylo dosaženo v generátoru těkavých sloučenin přechodných kovů. V tomto experimentálním uspořádání aparatury bylo dosaženo meze detekce 0,07 ng ml- 1 Cd a citlivosti 3,2 s ng-1 Cd. Dále bylo prokázáno, že generovanou těkavou formou jsou volné atomy Cd a to ve všech testovaných upořádáních. Klíčová slova atomová absorpční spektrometrie, kadmium, generování těkavých sloučenin, atomizace těkavých sloučenin
Chemical vapor generation of cadmium: detector comparison
Sagapova, Linda ; Štádlerová, Barbora ; Svoboda, Milan ; Kratzer, Jan ; Musil, Stanislav
A chemical vapor generation system was connected to an in-house assembled atomic fluorescence spectrometer (AFS) equipped with a miniature diffusion flame atomizer in order to assess its potential to Cd determination. Subsequently, analytical performance of three spectrometric detectors was compared (AAS, AFS, ICP-MS) with respect to Cd determination after volatile species generation.
Chemical vapor generation of cadmium for analytical atomic spectrometry
Sagapova, Linda ; Kodríková, Barbora ; Svoboda, Milan ; Musil, Stanislav ; Kratzer, Jan
Chemical vapor generation of cadmium volatile compounds was optimized, several reaction modifiers based on inorganic salts and complexes of CrIII+, CoII+, TiIII+, TiIV+ were tested. Their use resulted in 4-5 times enhancement in sensitivity, reflected also in corresponding increase of generation efficiency and better repeatability. Generation efficiency was determined from a comparison between sensitivities obtained with chemical vapor generation and conventional solution nebulization, both simultaneously coupled with inductively coupled plasma mass spectrometry. The identity of the generated cadmium compounds was identified.
Optimalizace podmínek chemického generování a atomizace těkavých specií kadmia pro atomovou absorpční spektrometrii
Sagapova, Linda ; Kratzer, Jan (vedoucí práce) ; Marschner, Karel (oponent)
Cílem této diplomové práce byla optimalizace podmínek generování a atomizace těkavé formy kadmia pro stanovení jeho stopových koncentrací metodou generování těkavých sloučenin (VCG) s detekcí atomovou absorpční spektrometrií (AAS). Byly testovány tři různé konstrukce generátorů těkavých sloučenin. Jednalo se o konvenční hydridový generátor v uspořádání průtokové injekční analýzy (FIA), dávkový generátor a generátor těkavých sloučenin přechodných kovů. Účinnost generování Cd za optimálních podmínek v konvenčním generátoru ve FIA uspořádání dosahovala pouze 4 %. Odstranění kyslíku rozpuštěného v reagenciích vedlo ke zvýšení účinnosti generování Cd v tomto systému na 12 %. Nejvyšší účinnosti generování Cd (54 %) bylo dosaženo v generátoru těkavých sloučenin přechodných kovů. V tomto experimentálním uspořádání aparatury bylo dosaženo meze detekce 0,07 ng ml- 1 Cd a citlivosti 3,2 s ng-1 Cd. Dále bylo prokázáno, že generovanou těkavou formou jsou volné atomy Cd a to ve všech testovaných upořádáních. Klíčová slova atomová absorpční spektrometrie, kadmium, generování těkavých sloučenin, atomizace těkavých sloučenin

Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.