Žádný přesný výsledek pro Kohout,, jJaroslav nebyl nalezen, zkusme místo něj použít Kohout jJaroslav ...
Národní úložiště šedé literatury Nalezeno 2 záznamů.  Hledání trvalo 0.04 vteřin. 
Study of the properties of hyperpolarized xenon-129 for magnetic resonance imaging
Rychnovský, Jan ; Nováková,, Sabina (oponent) ; Kohout,, jJaroslav (oponent) ; Bartušek, Karel (vedoucí práce)
The production of hyperpolarized gases (HpG), predominantly helium (3He) or xenon (129Xe), have found a steadily increasing range of applications in magnetic resonance imaging (MRI). Neither helium nor xenon are normally present in the body, thus the magnetic resonance experiments do not suffer from unwanted background signals. It has been demonstrated by several techniques of hyperpolarization that the magnetic polarization (magnetization) of the noble gas nuclei can be increased to levels that make practical application feasible. Hence, hyperpolarized gases may become a useful tool for non-invasive investigation of human lung ventilation, permitting static imaging during breathhold or probing the dynamics of inhalation/exhalation, or functional imaging. In inanimate nature, hyperpolarized gas can be used as a contrast medium for microporous materials, such zeolites, constructive materials in civil engineering, etc. This thesis describes the development and construction of a xenon (129Xe) hyperpolarization (Hp) device. Buying hyperpolarized xenon from other research centres abroad is inefficient mainly because of a need of a fast transport of HpXe under specific conditions. That was the main motivation for developing of our own technology for production of HpXe. Well-handled technology could allow a medical cooperation or cooperation with teams dealing with in/animate nature (microporous material, gels, agriculture, animals, etc.). The aim of this work is to study the hyperpolarized noble gases theory with concern to 129Xe and to experimentally prove and measure xenon relaxation times by the NMR. Since it is possible to store hyperpolarized noble gases for later use, this doctoral thesis also explores the potentials of hyperpolarized noble gas storage system and its theoretical and experimental solution. Mainly two types of experiments are described in the thesis. In both experiments, sealed cylindrical Simax sample filled with xenon and supplement gas – nitrogen, helium were used. The first type of experiment is based on thermally polarized xenon and the second on hyperpolarized xenon. For hyperpolarization of 129Xe a high-power laser was used. In this experiment, the relation between power spectral density of optical pumping beam and efficiency of HpXe production process was investigated. The optimal duration of optical pumping and relaxation times of HpXe were investigated too.
Study of the properties of hyperpolarized xenon-129 for magnetic resonance imaging
Rychnovský, Jan ; Nováková,, Sabina (oponent) ; Kohout,, jJaroslav (oponent) ; Bartušek, Karel (vedoucí práce)
The production of hyperpolarized gases (HpG), predominantly helium (3He) or xenon (129Xe), have found a steadily increasing range of applications in magnetic resonance imaging (MRI). Neither helium nor xenon are normally present in the body, thus the magnetic resonance experiments do not suffer from unwanted background signals. It has been demonstrated by several techniques of hyperpolarization that the magnetic polarization (magnetization) of the noble gas nuclei can be increased to levels that make practical application feasible. Hence, hyperpolarized gases may become a useful tool for non-invasive investigation of human lung ventilation, permitting static imaging during breathhold or probing the dynamics of inhalation/exhalation, or functional imaging. In inanimate nature, hyperpolarized gas can be used as a contrast medium for microporous materials, such zeolites, constructive materials in civil engineering, etc. This thesis describes the development and construction of a xenon (129Xe) hyperpolarization (Hp) device. Buying hyperpolarized xenon from other research centres abroad is inefficient mainly because of a need of a fast transport of HpXe under specific conditions. That was the main motivation for developing of our own technology for production of HpXe. Well-handled technology could allow a medical cooperation or cooperation with teams dealing with in/animate nature (microporous material, gels, agriculture, animals, etc.). The aim of this work is to study the hyperpolarized noble gases theory with concern to 129Xe and to experimentally prove and measure xenon relaxation times by the NMR. Since it is possible to store hyperpolarized noble gases for later use, this doctoral thesis also explores the potentials of hyperpolarized noble gas storage system and its theoretical and experimental solution. Mainly two types of experiments are described in the thesis. In both experiments, sealed cylindrical Simax sample filled with xenon and supplement gas – nitrogen, helium were used. The first type of experiment is based on thermally polarized xenon and the second on hyperpolarized xenon. For hyperpolarization of 129Xe a high-power laser was used. In this experiment, the relation between power spectral density of optical pumping beam and efficiency of HpXe production process was investigated. The optimal duration of optical pumping and relaxation times of HpXe were investigated too.

Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.