Národní úložiště šedé literatury Nalezeno 2 záznamů.  Hledání trvalo 0.01 vteřin. 
Is it possible to measure CO2 effluxes in an arable ecosystem using chambers without soil frames?
Juszczak, R. ; Acosta, Manuel ; Sakowska, K. ; Leśny, J. ; Uździcka, B. ; Chojnicki, B. H. ; Urbaniak, M. ; Olejnik, Janusz
The push-in chamber and chambers with alternative gaskets were tested under fi eld conditions in order to estimate the rates of under- or overestimation of the CO2 effl uxes measured with chambers placed directly on a soil surface (without collars). Th e experiment was conducted on a spring barley fi eld which was harvested just before the measuring campaign. Th e following were tested: 1) a pushed-in chamber with a sharp metal blade installed on the edge of the chamber walls which was inserted to a depth of 1–2 cm to the soil, 2) a chamber with a 10 cm wide and 3 cm high rubber gasket, and 3) a chamber with a 10 cm wide and 2 cm high neoprene gasket. Th e results indicated that the application of the pushed-in chamber led to overestimation of the fl uxes by 55%, while application of chambers with alternative gaskets led to underestimation of the fl uxes by 30–40% due to the leakage of the gas from the chamber headspace through holes beneath the gaskets. Our experiment confi rmed that soil frames should be applied in fi eld conditions to assure the tightness of the chambers. Other tested solutions increase the biases of the chamber measurements and increase the uncertainties of the estimated CO2 effl uxes.
Forest floor respiration of tuczno scots pine stands
Urbaniak, M. ; Pavelka, Marian ; Heronim Chojnicky, B. ; Juszczak, R. ; Dařenová, Eva ; Baran, M. ; Danielewska, A. ; Ziemblinska, K. ; Olejnik, Janusz
Tuczno forest is a 60-year-old Scots pine stand that is located in the North-West part of Poland. During the period between 20th and 25th August 2012 an experiment consisting of the measurement of forest fl oor CO2 effl ux was carried out. For this purpose, manual chamber systems were used. Measurements were taken at 60 collars located on a rectangular plot 25m x 45m. Th is research area was located in the range of footprint of the Eddy-covariance (EC) tower. Th e preliminary results indicate that the average CO2 effl ux from the forest fl oor, as measured during the experiment (5.09 μmol m-2 s-1), is lower than the total ecosystem respiration, estimated from EC data (6.25 μmol m-2 s-1). Spatial variability of soil CO2 effl ux (Rs) can be explained by humus thickness (Ht) variability; however, the tree root respiration can be considered a valuable part of CO2 emission from the forest bottom.

Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.