National Repository of Grey Literature 56 records found  beginprevious36 - 45nextend  jump to record: Search took 0.01 seconds. 
Reconstruction of discharging shakeout machine electric installation
Bednář, Vojtěch ; Blecha, Martin (referee) ; Pazdera, Ivo (advisor)
This Diploma work is concerned with the design of project documentation for discharging shakeout machine electric installation. This work continues in the Semestral project 2 in which the background of a new machine was made. Then, this work deals with the replacement of a switch room with required devices including the design of a new connecting cables and power streams. In the first part, the work deals with the control part of the device and the design of control and signal cables including the product documentation of the device. In the second part, the work deals with the proposal of building electro installation in which a new lighting and its use is described. The last part focuses on the coordination during the realization of a suggested device. In this part, all problems coming from the particular working procedures including a proposal of possible solutions are described. According to the project documentation and following realization, the documentation of final concept reflecting the real status of the device is described.
Evaluation of the posibilities of the new source connection to the power system from the voltage point of view
Wasserbauer, Vojtěch ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
This work deals with examining the possibility of connecting a new source to the distribution network of 110 kV and comparing the effects on the network with the involvement of new resources into two different circuits during operation in the winter and summer. It describes a steady operation of the network and solves the conditions for adding new sources into the grid. The result of this work presents possible problems in the electricity distribution system and a proposal of their possible removal.
Project of Photovoltaic Power Plant Grid Connection
Blažek, Tomáš ; Procházka, Aleš (referee) ; Orságová, Jaroslava (advisor)
This bachelors thesis deals with photovoltaic technology and economic evaluation of used technology equipment. The first part describes the technology for extraction of power from photovoltaic sources - transformer 22/0,4kV and its basic parts. Then there is the calculation of the amount of openings for cooling the transformer according to ČSN 33 3240. The second part focuses on the description of the major part of the photovoltaic plant. Here are divided solar panels on the material from which they are produced and the type of installation in the field. Next is describe the types of inverters, their principles and functions. The last part compares the different types of transformers and operating costs over the lifetime of plants (20 years), are described factors for proper selection of inverters and solar panels.
Evaluation of connection possibility of new power plant from voltage point of view.
Macháč, Petr ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
This thesis deals with load flow calculation of electrical network 110 kV before and after connection of power plant 100 MW to network node Prostějov. This grid can be supply from two substations 400/110 kV - load flow calculation is realized for two variants of supply - the first from substation Sokolnice and the second from substation Otrokovice. Result of this thesis is evaluation of voltage conditions and conductor overload.
Selected Parts of Construction-Technological Project of Substation 110 kV Ostava Hrabová
Škrobánková, Zuzana ; Bravenec, Roman (referee) ; Mohapl, Martin (advisor)
This thesis deals with construction and technological project of 110 kV substation in Ostrava Hrabová. Includes design mechanical assembly, time and financial plan, technological studies during the construction of the main building structure, schedule, project site equipment, budgets and other documents that are required to correct the construction.
Short - circuit conditions at Sokolnice 110 kV switching station following a direct 400/110 kV transformation
Hajdú, Lukáš ; Paar, Martin (referee) ; Blažek, Vladimír (advisor)
The goal of this bachelor´s thesis is to evaluate short-circuit conditions at the Sokolnice 110kV switching station before and after installation of a T402 transformer – before and after application of a direct 400/110kV transformation. By evaluating these conditions determine whether the originally installed protective elements (power circuit-breakers) are capable of fulfilling the new short-circuit requirements at the switching station. The thesis consists of two parts: the first part introduces the theory required to evaluate the short-circuit conditions at the switching station, while the second part calculates the actual short-circuit currents and power outputs. The methods used for calculation are sequential simplification and symmetrical components.
Study of the Possibility of Extention of 110 kV substation in TKV
Poledník, Petr ; Grym, Rudolf (referee) ; Orságová, Jaroslava (advisor)
This project are deal with the posibility of extention of 100 kV substation in TKV. What is important for project is restriction of conditions for realization. The aim for project is create individual possibilities of solutions and consequently their evaluation.
Load flow analyses of reactive power in distribution system
Krátký, Michal ; Kašpírek,, Martn (referee) ; Topolánek, David (advisor)
This thesis is focused on issues with transmission of reactive power though the distribution line of E.ON area. The goal is to find out where and in what rate are overflows of reactive power and to project the correctional steps to minimize this overflow. In this solution, there were used data of dispatcher measurement, which were processed by created source code in Matlab. The processing was analyzed for final conclusion. There were discovered shortages in overflow of reactive power in transfer between distribution and transmission line and in unsuitably regulated capacity power factor in Planá power plant and wrong automatic regulation of turns in 440/110kV substation Dasný. The action to minimize overflows of reactive power was projected by decompensation reactor placed in T101 and T102 transformers in substation Tábor.
Calculation of the network steady state on the voltage level 110 kV
Macháč, Petr ; Vaculík, Petr (referee) ; Mastný, Petr (advisor)
This thesis deals with load flow calculation of electrical network 110 kV before and after the connection to the 70MW gas supply and the 58MW steam and gas supply. This grid can be powered from two 400/110kV substations, namely Sokolnice and Otrokovice. The load flow calculation is realized for the power supply either from Otrokovice or Sokolnice. Furthermore, the calculation of the uni-phase and three phase short circuits in the substations of 110kV network is realized in this thesis. The result of the thesis is the assessment of the voltage ratio in the network, current load of the power line and short circuit resistance of the substations.
Individual stand-by of incoming feeder of Energetika Trinecs´ 6 kV substation
Borski, Roman ; Hodula, Petr (referee) ; Topolánek, David (advisor)
The thesis titled Individual stand-by of incoming feeder of Energetika Třinec 6 kV substantion is theoreticaly and practically concived work that offers comprehensive information on automatic standby focused on the selected operation of Energetika Třinec. At present, the standby is in authention mode and thesis solves shutdown of transformer T5. The extract of automatic device indicates trouble-free operation and thesis focus on the power take-off for transformer T5. The theoretical part provides information about problems of own comsumption of power plants, automatic device of standby and protection of electrical equipment. Thesis also sloves the protection settings, which is supported by calculations of short-circuit currents. The practical part is formed from the suggestion of solution in accordance to current criteria and the evaluation of possible settings of protective automatic devices together with an assessment of implementation option of standby. The aim of the thesis is to perform analysis of standby and evaluate effects which causes shutdown of own comsumption part. The final part assesses current settings of protection based on calculated values. Existing protections are unsuitable and it is recomennded to deploy digital multi-stage protections as a replacement for present relay protections.

National Repository of Grey Literature : 56 records found   beginprevious36 - 45nextend  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.