National Repository of Grey Literature 324 records found  beginprevious21 - 30nextend  jump to record: Search took 0.01 seconds. 
Airconditioning in healthcare facilities
Růžička, Věroslav ; Jelínek, Ondřej (referee) ; Rubina, Aleš (advisor)
This bachelor thesis deals with design of air conditioning equipment serving the spaces of hospital inpatient ward and its associated facilities. Equipments designed in the computational part have the task to transport adapted fresh air to hospital premises. The system is devided into two units. Primary mechanism operates bedrooms and their sanitary facilities. Secondary mechanism operates associated facilities. Both mechanisms are designed so that hot air can ventilate in winter. To cover the heat load in summer, fancoil units are designed. Device number one is also able to manage the treatment of humidity. The theoretical part of the thesis focuses on air filters and filtration of atmospheric air.
Ventilation of low-energy houses
Kubisz, Pavel ; Fišer, Jan (referee) ; Charvát, Pavel (advisor)
Dissertation deals with division and description progressive trends of ventilation of low-energy houses. Forasmuch as ventilation is participant in total heat consumption, It is here practical example how total heat consumption depend on ventilation heat consumption and heat consumption by construction. At the close is showed when is good, or bad, to use ventilation with recuperation.
Determination of Blood Pressure
Plch, Miroslav ; Smital, Lukáš (referee) ; Čmiel, Vratislav (advisor)
The thesis includes a general introduction to monitoring and measurement of blood pressure of horses, the design of algorithms for pressure curve detection and the calculation of respiratory variabilities in mechanical ventilation under anaesthesia. The first two chapters focus on anatomy, on characteristics of blood flow and on vascular system. Then it deals with the measurement of blood pressure, monitoring of a horse under anaesthesia and it describes particular thermodynamic parameters. In the following part of the thesis, the methods of pressure curve detection are described. The last part contains the description of an algorithm designed for detection of pressure curve of horses in the environment of the program LabVIEW. The program calculates, displays and saves variabilities of systolic pressure, pulse volume, pressure amplitude, pulse frequency, peripheral resistance and vascular expansion from the detected values.
Air-conditioning of offices
Trávníček, Tomáš ; Pavelek, Milan (referee) ; Janotková, Eva (advisor)
The aim of a master thesis is the proposal of the air conditioning system for one floor of offices in the administrative building. Propsal of the air conditioning system is based on the calculated ventilation air, further on thermal looses, thermal gains and then psychrometric calculation for summer and winter operation. Obtained values are the basis of the proposal of the air ducts with ending parts like a diffusers. It also obtains the proposal of the air conditioning unit with design of machina room. The proposal and all calculations are supplemented with drawing documentation and list of items.
Ventilation of the wellness sports center
Prchalová, Nikol ; Uher, Pavel (referee) ; Blasinski, Petr (advisor)
The bachelor thesis deals with application for design of air–conditioning equipment of wellness sports center in Znojmo. This work is divided into three parts. The first part is theoretical, which is dedicated to the issue of swimming pool halls. It sumarizes the basic information from the requirements for the microclimate of swimming pools, through the issue of dangerous gases, the issue of evaporation to the introduction of air-conditioning unists and their operations. The calculation part deals with the project of three air-conditioning units into three functional units of the object. This includes air-conditioning of the swimming pool and badminton courts and warm-air ventilation of the premises. The last part is the project documentation of ventilation.
Heating and hot water preparation of recreation center
Hakl, Jaroslav ; Horká, Lucie (referee) ; Počinková, Marcela (advisor)
Content of this bachelor thesis is heating and hot water preparation of recreation centre in the village Ostužná, district Jeseník. Object have 2 above-ground floors. Ground floor is mainly used to meet people in play room or in common room. First floor is situated six accommodation units with private bathroom and toilet. Technical facilities are situated in ground floor and is consists of boiler room and the adjacent fuel storage. For heating is primary used grasifying boiler. Secondary source for hot water preparation is solar systém, that is supplemented by an electric heater in the absence of sunshine. Heating systém is in horizontal double-pipe version with distributor and collector in each floor. The Individual branches on the distributor and collector connected are sections of a single accommodation unit, that can be individually regulated. Radiators are designed as boards in the VK design.
Ventilation and cooling system for an apartment in block of flats
Uřičář, Filip ; Fišer, Jan (referee) ; Hejčík, Jiří (advisor)
This Master’s Thesis deals with the design of ventilation and cooling of an under roof flat in a tenement building, built in the 1980s, and consists of five main parts. Within the first main part, the thesis is dedicated to the research of the current state of knowledge in the area ofventilation and cooling of residential premises, secondly, there is a detailed description of a particular flat, thirdly, the calculation for the optimal design of ventilation and cooling are made and, in the fourth part, suggested solutions are proposed with the following evaluation of them including the overall summary. The design of ventilation and cooling was carried out according to the design procedures with respect to the relevant standards and optimized to achieve the desired effect with respect to the requirements of the owner of a housing unit. As a solution, the ventilation of a flat by the Jablotron Futura´s ventilating unit and three variants of a flat cooling were proposed. After the evaluation of all cooling variants, the Sinclair´s multisplit system of cooling was chosen as the most suitable one.
Energy retrofit of a stand-alone house
Stupka, Jaroslav ; Pech, Ondřej (referee) ; Charvát, Pavel (advisor)
The aim of the master’s thesis was to design heating, ventilation and cooling systems and to evaluate possibility of using renewable sources in case of a reconstructed two-storey family house. Air to water heat pump and floor system were designed to ensure both heating and cooling supply in the building. A heat recovery ventilation system was proposed. Gains of electrical energy from photovoltaic array were calculated and then possibility of coverage the heat pump consumption was evaluated. The thesis contains required calculations including building heat losses, heat gains, air exchange rates and the dimensioning of all mentioned systems. Technical drawing is also comprised.
Energy assessment of buildings
Velísková, Eva ; Maurerová, Lenka (referee) ; Hirš, Jiří (advisor)
The master’s thesis deals with energy assessment of buildings according to a current valid legislature. In the first part the energy assessments problems are solved. The next part solves the energy concept of the educational building, Pavilion P4, AdMaS centre of Faculty of Civil Engineering of BUT, in the form of project documentation. In the part of thesis there is a simulation characterizing dynamic behavior of building. The thesis point is the evaluation of energy balance and a draft of measures leading to the power consumption decrease.
Airconditioning of the house to the medical service
Vytasil, Michal ; Jelínek, Ondřej (referee) ; Rubina, Aleš (advisor)
This bachelor's thesis deals with the design of air conditioning equipment in the house to the medical service. The solution is the basement floor with a waiting room, reception and sanitary rooms and 1.NP with surgery. Heating load of part of the basement is completely drained air handling units, in other rooms are used sub-system with fan coil units. Sanitary rooms are exhaust ventilation ceiling-suspended equipment. In the theoretical part of the thesis focuses on the bypass factor, surface temperature of the heat sink and their effect on the dehumidification.

National Repository of Grey Literature : 324 records found   beginprevious21 - 30nextend  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.