Bioimpedance signal processing
Valíčková, Vladimíra ; Vondra, Vlastimil (referee) ; Soukup, Ladislav (advisor)
Theoretical part of this Bachelor thesis deals with properties measurement and use of bioim-pedance signal for medical diagnostics. The practical part deals with detection of important points in derivate bioimpedance signal that may be further used in various medical applicati-ons. This work compares three detection methods. The best results were achieved by a de-tection with fixed interval there were excluded only 1,09 % values. Very similar results had detector dependent on constant bioimpedance. Here was excreted 1.18 % of detections. Algo-rithms that are dependent on length of RR interval perform worse. Furthermore, there is cal-culated the Pulse wave velocity in six parts of the human body in a horizontal and tilt patient position. In the tilt position were the pulse wave velocity about 38.59 % faster than in hori-zontal.
Bioimpedance Signal Processing
Valíčková, Vladimíra
This study deals with detection of important points in derivate bioimpedance signal that may be further used in various medical applications, for example in calculation of the Pulse wave velocity. This work compares three detection methods. The best results were achieved by a detection with fixed interval. Algorithms that are dependent on constant bioimpedance and length of RR interval perform worse.
Bioimpedance signal processing
Valíčková, Vladimíra ; Vondra, Vlastimil (referee) ; Soukup, Ladislav (advisor)
Theoretical part of this Bachelor thesis deals with properties measurement and use of bioim-pedance signal for medical diagnostics. The practical part deals with detection of important points in derivate bioimpedance signal that may be further used in various medical applicati-ons. This work compares three detection methods. The best results were achieved by a de-tection with fixed interval there were excluded only 1,09 % values. Very similar results had detector dependent on constant bioimpedance. Here was excreted 1.18 % of detections. Algo-rithms that are dependent on length of RR interval perform worse. Furthermore, there is cal-culated the Pulse wave velocity in six parts of the human body in a horizontal and tilt patient position. In the tilt position were the pulse wave velocity about 38.59 % faster than in hori-zontal.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.