Evaluation of Voltage Events from COMTRADE Records
Poul, Martin ; Topolánek, David (referee) ; Krčál, Vít (advisor)
The bachelor thesis focuses on the evaluation and detection of voltage events and rapid voltage changes according to ČSN EN 61000-4-30 and their statistical evaluation. The thesis describes the monitored voltage characteristics used for detection and evaluation, primarily based on the standard describing the quality of electrical energy ČSN EN 50160. The work includes a program developed for the detection and evaluation of these events. Using the program, voltage events from real operation of 22 and 110 kV power grids are evaluated.
Evaluation of Possibility of New Source Connection With Regard to Nodal Voltage
Němec, Jan ; Topolánek, David (referee) ; Toman, Petr (advisor)
Connection new source of electrical energy into distribution network is important for existing one for reasons its rating and dimensioning. It is even evaluate, whether possibility connection new source in to network is real and do not endanger continuous running distribution system. This work has shown, what conditions are need realize for connection source into distribution network in view of voltage ratio. Next it must incidence harmonic current and affecting centralized telecontrol signal about reasoning. Against a background examination connection source are administrative acts, which forms basis of successful connection. On basis lets request of connection mostly study of connection working up. This study contains concrete calculation and examination individual factors for connection new source. Next put mind to connection wind power station, because wind power stations are very special source for connection into distribution network. Bigger demands are putting on them and stricter examination of connection to site must be done. Because during time unit (day, week and month) they have various strain diagram. Which makes higher straining of distribution and necessity have reserve of electrical energy for case fail wind power station owing to windless ness. In the end, there is referred to practical examination example of possibility connecting. As this example was chosen examination of wind park to 110 kW network with 32 MVA installed power from view of voltage ratio. Solution process is given by replacement of part of given Picells link and by calculation steady state of node site system with Gauss-Seidels iteration method. After that follows evaluation of voltage change in the site before and after connection of source to the network, which can not be higher than 2%. In this example is this condition satisfied and from a view of voltage ratio there is nothing to obstruct for connection new source to network.
Increase the Rated Voltage of the Vehicle's Circuit - Study
Horák, Richard ; Vítek, Ondřej (referee) ; Hájek, Vítězslav (advisor)
The point of this work is evaluate the parameters of automotive electric system and according to these properties choose suitable norm of higher voltage, propose conception of system and with analyst calculation suggest basic granary parameters of higher voltage. This calculation is enclosed. In the work is mentioned a historical development of required escalation in system and therewith connected changes of specified levels of system tension. As an exemplification of escalation calculus hereof electrical equipment, installed onto motor powered vehicle, are mentioned in attachment schema's of four vehicles Škoda Auto a.s.
Evaluation of Possibility of New Source Connection With Regard to Nodal Voltage
Němec, Jan ; Topolánek, David (referee) ; Toman, Petr (advisor)
Connection new source of electrical energy into distribution network is important for existing one for reasons its rating and dimensioning. It is even evaluate, whether possibility connection new source in to network is real and do not endanger continuous running distribution system. This work has shown, what conditions are need realize for connection source into distribution network in view of voltage ratio. Next it must incidence harmonic current and affecting centralized telecontrol signal about reasoning. Against a background examination connection source are administrative acts, which forms basis of successful connection. On basis lets request of connection mostly study of connection working up. This study contains concrete calculation and examination individual factors for connection new source. Next put mind to connection wind power station, because wind power stations are very special source for connection into distribution network. Bigger demands are putting on them and stricter examination of connection to site must be done. Because during time unit (day, week and month) they have various strain diagram. Which makes higher straining of distribution and necessity have reserve of electrical energy for case fail wind power station owing to windless ness. In the end, there is referred to practical examination example of possibility connecting. As this example was chosen examination of wind park to 110 kW network with 32 MVA installed power from view of voltage ratio. Solution process is given by replacement of part of given Picells link and by calculation steady state of node site system with Gauss-Seidels iteration method. After that follows evaluation of voltage change in the site before and after connection of source to the network, which can not be higher than 2%. In this example is this condition satisfied and from a view of voltage ratio there is nothing to obstruct for connection new source to network.
Increase the Rated Voltage of the Vehicle's Circuit - Study
Horák, Richard ; Vítek, Ondřej (referee) ; Hájek, Vítězslav (advisor)
The point of this work is evaluate the parameters of automotive electric system and according to these properties choose suitable norm of higher voltage, propose conception of system and with analyst calculation suggest basic granary parameters of higher voltage. This calculation is enclosed. In the work is mentioned a historical development of required escalation in system and therewith connected changes of specified levels of system tension. As an exemplification of escalation calculus hereof electrical equipment, installed onto motor powered vehicle, are mentioned in attachment schema's of four vehicles Škoda Auto a.s.