National Repository of Grey Literature 4 records found  Search took 0.04 seconds. 
Testing of an Accuracy of Mobile Laser Scanning
Hoffmannová, Lada ; Volařík, Tomáš (referee) ; Kuruc, Michal (advisor)
Diploma thesis describes collecting of data by mobile mapping system Riegl VMX-450. Science centre AdMas was captured with mobile mapping system. For the purpose of testing the accuracy, a calibration field was constructed in AdMaS. Main part of the thesis deals with testing of the accuracy of point cloud. Calibration field's coordinates were obtained by adjustment of the geodetic network using the least squares adjustment. During the testing, the coordinates of the calibration field points determined by the adjustment of the geodetic network and the coordinates of the points determined from the point cloud were compared. Another part of the work deals with testing of the accuracy, when target's position is in different height levels.
Determination of coordinates and heights of calibration field points
Pospíšil, Ondřej ; Vondrák, Jiří (referee) ; Machotka, Radovan (advisor)
The bachelor's thesis describes the determination of coordinates and heights of calibration field points in the AdMaS complex. An auxiliary measuring network was built in the specified locality. From the tops of this network, a detailed survey of the calibration field points followed. The main part of the work deals with testing the accuracy of determining the coordinates and heights of points. The final part of the work deals with the comparison and testing of the accuracy of determining the coordinates and heights of points between the new determination of the points of the calibration field and the determination from the previous stages of measurement. All protocols, calculations, lists of coordinates, overviews, including a technical report are located in the appendices to this bachelor's thesis.
Determination of coordinates and heights of calibration field points
Pospíšil, Ondřej ; Vondrák, Jiří (referee) ; Machotka, Radovan (advisor)
The bachelor's thesis describes the determination of coordinates and heights of calibration field points in the AdMaS complex. An auxiliary measuring network was built in the specified locality. From the tops of this network, a detailed survey of the calibration field points followed. The main part of the work deals with testing the accuracy of determining the coordinates and heights of points. The final part of the work deals with the comparison and testing of the accuracy of determining the coordinates and heights of points between the new determination of the points of the calibration field and the determination from the previous stages of measurement. All protocols, calculations, lists of coordinates, overviews, including a technical report are located in the appendices to this bachelor's thesis.
Testing of an Accuracy of Mobile Laser Scanning
Hoffmannová, Lada ; Volařík, Tomáš (referee) ; Kuruc, Michal (advisor)
Diploma thesis describes collecting of data by mobile mapping system Riegl VMX-450. Science centre AdMas was captured with mobile mapping system. For the purpose of testing the accuracy, a calibration field was constructed in AdMaS. Main part of the thesis deals with testing of the accuracy of point cloud. Calibration field's coordinates were obtained by adjustment of the geodetic network using the least squares adjustment. During the testing, the coordinates of the calibration field points determined by the adjustment of the geodetic network and the coordinates of the points determined from the point cloud were compared. Another part of the work deals with testing of the accuracy, when target's position is in different height levels.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.