Load Flow Calculation and Design of Distance Protection Relay Settings of 110 kV Overhead Line
Jasenský, Filip ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
Bachelor thesis load flow calculation and design of distance protection relay settings of 110 kV overhead line acquaints with the theory calculation of steady operation, short-circuit conditions and a proposal setting the distance protection. The theoretical part is made an example of a simple calculation to show leadership methods of calculation. The practical part is a calculation of steady operation and short-circuit conditions. Short-circuit ratios are calculated for a single operation and parallel operation of transformers in Otrokovice. Calculated using the initial shock symmetrical output from the calculation of short-circuit conditions is verified by short circuit resistance of substations. The practical section setting the distance protection ABB REL 316*4 and compensation earth faults. Calculation of steady state and short-circuit conditions designed basic operational state of the network, for which the design of a distance protection relay settings.
Calculation of HV line distance relay setings
Pustowka, Pavel ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
This work is divided into practical and theoretical part. The first part deals with defective states on ehv lines, especially short-circuits and their calculation, further discusses about distance protections and the theory necessary for their correct adjustment. The second part contains practical calculation of short-circuit conditions and adjustment for distance protection on selected part of 110 kV network, belonging to EO.N company. The result of the work are values needed for adjustment all distance protection in entered part of the network.
Short-circuit Calculation of Local Distribution Network
Byrtus, Jiří ; Paar, Martin (referee) ; Topolánek, David (advisor)
This thesis deals with transient phenomena in the electricity grid - especially with short-circuits. First part describes short-circuit types, reasons for their commencement and also consequences of their functioning. The thesis further shows waveforms of short-circuit currents and its components. A method of calculating short-circuits currents, using the constituent systems and the basic equations for calculating short-circuit impedances are also mentioned here. Relations and methods are based on valid standards of IEC 60909 – 0. The second part indicates the calculation of two-phase and three-phase short-circuit currents for specific network of industrial building. This calculation aims to verify the dimensioning of substations for short-circuit currents after connecting a synchronous generator with given power to the main substation.
Calculation of distance protection relay setting for 110kV line.
Bartoš, Petr ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
This work deals with both the calculation of short circuit conditions of 110 kV network in the Czech Republic. This network is divided into two parts, each of which feeds a 400/110 kV substation and the calculation is performed for different locations of a short circuit. The second part deals with the calculation of distance protection settings for one part of this network. The result of this work are the values of network parameters needed to set up distance protection, which protects our individual lines of the network.
Axial Channel Effect on Leakage Reactance in Split-Winding Transformer.
Mrajca, M. ; Cipín, R.
Transformer short-circuit impedance is one of the most important output parameters in the design process. Its value depends mainly on leakage inductance, which is different for one or both shorted output windings during short-circuit test of split-winding transformer with input windings working in parallel. In this paper, an analysis of split-winding transformer with changing axial channel between winding pairs and its effect on leakage reactance has been performed for both shorted outputs. The effect is evaluated with analytical calculations, 3D and 2D finite element method simulations on a typical 5300 kVA three-phase oil transformer. The results show that the channel can’t be neglected in short-circuit calculation and the geometry of the transformer can be simplified to 2D with minimal influence on results.
Calculation of HV line distance relay setings
Pustowka, Pavel ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
This work is divided into practical and theoretical part. The first part deals with defective states on ehv lines, especially short-circuits and their calculation, further discusses about distance protections and the theory necessary for their correct adjustment. The second part contains practical calculation of short-circuit conditions and adjustment for distance protection on selected part of 110 kV network, belonging to EO.N company. The result of the work are values needed for adjustment all distance protection in entered part of the network.
Load Flow Calculation and Design of Distance Protection Relay Settings of 110 kV Overhead Line
Jasenský, Filip ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
Bachelor thesis load flow calculation and design of distance protection relay settings of 110 kV overhead line acquaints with the theory calculation of steady operation, short-circuit conditions and a proposal setting the distance protection. The theoretical part is made an example of a simple calculation to show leadership methods of calculation. The practical part is a calculation of steady operation and short-circuit conditions. Short-circuit ratios are calculated for a single operation and parallel operation of transformers in Otrokovice. Calculated using the initial shock symmetrical output from the calculation of short-circuit conditions is verified by short circuit resistance of substations. The practical section setting the distance protection ABB REL 316*4 and compensation earth faults. Calculation of steady state and short-circuit conditions designed basic operational state of the network, for which the design of a distance protection relay settings.
Short-circuit Calculation of Local Distribution Network
Byrtus, Jiří ; Paar, Martin (referee) ; Topolánek, David (advisor)
This thesis deals with transient phenomena in the electricity grid - especially with short-circuits. First part describes short-circuit types, reasons for their commencement and also consequences of their functioning. The thesis further shows waveforms of short-circuit currents and its components. A method of calculating short-circuits currents, using the constituent systems and the basic equations for calculating short-circuit impedances are also mentioned here. Relations and methods are based on valid standards of IEC 60909 – 0. The second part indicates the calculation of two-phase and three-phase short-circuit currents for specific network of industrial building. This calculation aims to verify the dimensioning of substations for short-circuit currents after connecting a synchronous generator with given power to the main substation.
Calculation of distance protection relay setting for 110kV line.
Bartoš, Petr ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
This work deals with both the calculation of short circuit conditions of 110 kV network in the Czech Republic. This network is divided into two parts, each of which feeds a 400/110 kV substation and the calculation is performed for different locations of a short circuit. The second part deals with the calculation of distance protection settings for one part of this network. The result of this work are the values of network parameters needed to set up distance protection, which protects our individual lines of the network.