National Repository of Grey Literature 2 records found  Search took 0.00 seconds. 
The design of fast magnetorheological valves without the use of ferrites
Strmiska, Tomáš ; Růžička, Bronislav (referee) ; Strecker, Zbyněk (advisor)
This diploma thesis deals with development of a new generation of magnetic circuits of fast magnetoreological (MR) dampers that will not use problematic ferrite materials. To ensure a short response time, eddy currents must be avoided. Using the Finite Element Method, 2 solutions were proposed - the use of soft magnetic composites with high electrical resistance and the cutting of grooves in metallic material. Subsequently, 2 magnetic circuits were produced - one from Sintex SMC prototyping material composite and one from 11SMn30 steel with 48 deep grooves 0,35 mm wide. Both were implemented into the MR damper and tested on a hydraulic pulsator. The results of the experiments were compared with 2 different MR dampers: one with 11SMn30 magnetic circuit without grooves and another with the Epcos N87 ferrite magnetic core. It has been found that both new circuits have ensured an equally short response of the damper force to the change of electric current like ferrite. At the same time, a much larger dynamic range was ensured. Compared to 11SMn30 without grooves, the new circuits provided approximately 7x faster response.
The design of fast magnetorheological valves without the use of ferrites
Strmiska, Tomáš ; Růžička, Bronislav (referee) ; Strecker, Zbyněk (advisor)
This diploma thesis deals with development of a new generation of magnetic circuits of fast magnetoreological (MR) dampers that will not use problematic ferrite materials. To ensure a short response time, eddy currents must be avoided. Using the Finite Element Method, 2 solutions were proposed - the use of soft magnetic composites with high electrical resistance and the cutting of grooves in metallic material. Subsequently, 2 magnetic circuits were produced - one from Sintex SMC prototyping material composite and one from 11SMn30 steel with 48 deep grooves 0,35 mm wide. Both were implemented into the MR damper and tested on a hydraulic pulsator. The results of the experiments were compared with 2 different MR dampers: one with 11SMn30 magnetic circuit without grooves and another with the Epcos N87 ferrite magnetic core. It has been found that both new circuits have ensured an equally short response of the damper force to the change of electric current like ferrite. At the same time, a much larger dynamic range was ensured. Compared to 11SMn30 without grooves, the new circuits provided approximately 7x faster response.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.