National Repository of Grey Literature 11 records found  1 - 10next  jump to record: Search took 0.02 seconds. 
Possibilities of dispersed reinforcement for lightweight concrete
Novotná, Aneta ; Žítt, Petr (referee) ; Láník, Jaromír (advisor)
Master´s thesis deals with some problems associated with utilisation of lightweight concrete from the porous aggregates in the load – carrying structures. The thesis focuses on the possibilities of the increase of the cement composites toughness using dispersed reinforcement. Lightweight concretes were reinforced with a combination of different lengths of polypropylene fibers Forta Ferro. There were used polypropylene fibers of three lengths 19, 38, 54 mm. The thesis is divided into theoretical, experimental and static part.
Fibre reinforcement with plasma in cement composites
Žižková, Lucie ; Hela,, Rudofl (referee) ; Bodnárová, Lenka (advisor)
The usage of polymer fibres can be increased by the new progressive method of the plasma treatment. This thesis is focused on verification of the influence of the low-temperature treatment on polymer fibres´ surface used in concrete. The treatment of polypropylene fibres in low-temperature plasma is described in the theoretical part. The impact of the treatment on the volume differences of cement composites is also evaluated. The influence of the addition of commercially available fibres and plasma treated fibres on the volume differences of cement composites is also experimentally verified.
Study of the properties of cement composites with polypropylene fiber modified low-temperature plasma
Žižková, Lucie ; Herka, Petr (referee) ; Bodnárová, Lenka (advisor)
Plasma treatment of polypropylene fibers presents a new progressive method, how to increase the utility properties of these fibers. The thesis is focused on verifying the effect of surface treatment of polypropylene fibers in concrete with low-temperature plasma discharge in the normal atmosphere. The paper describes the procedure for treatment of polypropylene fibers with low-temperature plasma and evaluate the impact of this adjustment on the volume changes of cement composites. It should also be emphasized that the thesis is focused on the initial volume changes, ie volume changes in the early stages of solidification and only for your own mixture, which is not considered an external load. Subsequently, the experimental verification of the effect of the addition made commercially available fibers and fibers treated plasma volume changes to a selected physico-mechanical properties of the test compounds.
Behavior of concrete at high temperatures
Dvořáková, Michaela ; Bruckner,, Dipl Heinrich (referee) ; Bodnárová, Lenka (advisor)
The aim of this diploma thesis is to focus on the resistance of concrete exposed to high temperatures especially with focus of resistance against explosive spalling as well as clarifying the mode of action of various types of polypropylene fibres. The theoretical part is an introduction to the issues of explosive spalling, its mechanisms and majority influencing factors. Further description of the processes taking place in the structure of concrete under extreme thermal load, distribution and size of pores in concrete, thermal load, temperature-time curves and their applications, methods of elimination of negative behaviour of concrete exposed to thermal loading (passive and active methods), mode of action of polypropylene fibres and more is also included in the theoretical part. The main aim of experimental part is to verify the function of polypropylene fibers of various Melt Flow Indexes (MFI) and dosage. Primarily, the test samples with content of the PP-fibers are compared to the reference sample without fibers. Secondarily, the samples with standard PP-fibers (with MFI 25) with dosage 2.0 kg/m3 are compared to samples with modified PP-fiber (with MFI 2500) of dosage 0.9 kg/m3. Photogrammetric images were used for evaluation and comparison of spalled surfaces and its depth. Determination of the softening temperature and melting point of the modified and standard PP-fibers was made by using a high temperature microscope video. The second part of the experimental work was to define concrete permeability at different temperatures and pressures. Permeability was measured at temperatures of 20°C, 90°C, 150°C, 175°C, 200°C, 225°C and 250°C and at pressure of 0.2, 0.4 and 0.6 MPa.
The concrete with a higher resistance to high temperatures
Mikulinec, David ; Hela,, Rudolf (referee) ; Bodnárová, Lenka (advisor)
The result of this master’s thesis is acquaintance with the issues of cement concrete resistance to high temperatures. This work describes the processes ongoing in the structure of concrete at extreme thermal loads and analysis of effects of high temperatures on the individual components of reinforced concrete structures is given, then influence of high temperatures and fire on the aggregates, matrix, reinforcement steel and the resulting changes in their properties. In the experimental part is given design of composition of concrete with a higher resistance to high temperatures and subsequent verification of the physico-mechanical properties of sample of concrete after exposure to temperatures at intervals of 200 ° C, 400 ° C, 600 ° C and 900 ° C. In individual recipes were observed changes of volume weight, changes of compressive strength and tensile strength flexural , tensile strength of surface layers and the occurrence of cracks and then were compared the results of thermally loaded and unloaded samples. The benefit in this issue is to evaluate the surface appearance of samples after heat load - study of area of crack and measurement of their width - was used according to the methodology's authors Xing, Hebert, Noumowe a Ledesert given in Cement and Concrete Research. This methodology allows to quantify changes of surface, after temperature load.
Study of the properties of cement composites with polypropylene fiber modified low-temperature plasma
Žižková, Lucie ; Herka, Petr (referee) ; Bodnárová, Lenka (advisor)
Plasma treatment of polypropylene fibers presents a new progressive method, how to increase the utility properties of these fibers. The thesis is focused on verifying the effect of surface treatment of polypropylene fibers in concrete with low-temperature plasma discharge in the normal atmosphere. The paper describes the procedure for treatment of polypropylene fibers with low-temperature plasma and evaluate the impact of this adjustment on the volume changes of cement composites. It should also be emphasized that the thesis is focused on the initial volume changes, ie volume changes in the early stages of solidification and only for your own mixture, which is not considered an external load. Subsequently, the experimental verification of the effect of the addition made commercially available fibers and fibers treated plasma volume changes to a selected physico-mechanical properties of the test compounds.
Behavior of concrete at high temperatures
Dvořáková, Michaela ; Bruckner,, Dipl Heinrich (referee) ; Bodnárová, Lenka (advisor)
The aim of this diploma thesis is to focus on the resistance of concrete exposed to high temperatures especially with focus of resistance against explosive spalling as well as clarifying the mode of action of various types of polypropylene fibres. The theoretical part is an introduction to the issues of explosive spalling, its mechanisms and majority influencing factors. Further description of the processes taking place in the structure of concrete under extreme thermal load, distribution and size of pores in concrete, thermal load, temperature-time curves and their applications, methods of elimination of negative behaviour of concrete exposed to thermal loading (passive and active methods), mode of action of polypropylene fibres and more is also included in the theoretical part. The main aim of experimental part is to verify the function of polypropylene fibers of various Melt Flow Indexes (MFI) and dosage. Primarily, the test samples with content of the PP-fibers are compared to the reference sample without fibers. Secondarily, the samples with standard PP-fibers (with MFI 25) with dosage 2.0 kg/m3 are compared to samples with modified PP-fiber (with MFI 2500) of dosage 0.9 kg/m3. Photogrammetric images were used for evaluation and comparison of spalled surfaces and its depth. Determination of the softening temperature and melting point of the modified and standard PP-fibers was made by using a high temperature microscope video. The second part of the experimental work was to define concrete permeability at different temperatures and pressures. Permeability was measured at temperatures of 20°C, 90°C, 150°C, 175°C, 200°C, 225°C and 250°C and at pressure of 0.2, 0.4 and 0.6 MPa.
Possibilities of dispersed reinforcement for lightweight concrete
Novotná, Aneta ; Žítt, Petr (referee) ; Láník, Jaromír (advisor)
Master´s thesis deals with some problems associated with utilisation of lightweight concrete from the porous aggregates in the load – carrying structures. The thesis focuses on the possibilities of the increase of the cement composites toughness using dispersed reinforcement. Lightweight concretes were reinforced with a combination of different lengths of polypropylene fibers Forta Ferro. There were used polypropylene fibers of three lengths 19, 38, 54 mm. The thesis is divided into theoretical, experimental and static part.
The concrete with a higher resistance to high temperatures
Mikulinec, David ; Hela,, Rudolf (referee) ; Bodnárová, Lenka (advisor)
The result of this master’s thesis is acquaintance with the issues of cement concrete resistance to high temperatures. This work describes the processes ongoing in the structure of concrete at extreme thermal loads and analysis of effects of high temperatures on the individual components of reinforced concrete structures is given, then influence of high temperatures and fire on the aggregates, matrix, reinforcement steel and the resulting changes in their properties. In the experimental part is given design of composition of concrete with a higher resistance to high temperatures and subsequent verification of the physico-mechanical properties of sample of concrete after exposure to temperatures at intervals of 200 ° C, 400 ° C, 600 ° C and 900 ° C. In individual recipes were observed changes of volume weight, changes of compressive strength and tensile strength flexural , tensile strength of surface layers and the occurrence of cracks and then were compared the results of thermally loaded and unloaded samples. The benefit in this issue is to evaluate the surface appearance of samples after heat load - study of area of crack and measurement of their width - was used according to the methodology's authors Xing, Hebert, Noumowe a Ledesert given in Cement and Concrete Research. This methodology allows to quantify changes of surface, after temperature load.
Properties of cement composites with fiber reinforcement
Jankech, Filip ; Sitek,, Libor (referee) ; Bodnárová, Lenka (advisor)
This thesis summarizes the knowledge of the possibility of using organic fibres as dispersed reinforcement into cement composites. It is concretely a summary of knowledge about the types and properties of synthetic and cellulosic fibres, their influence on the properties of fresh and hardened cement composite and lastly a description of the fire resistance of cement composites and the effect of organic fibres on the action of those composites at high temperatures and in the presence of fire. The experimental part is supposed to verify the effect of the cellulose fibres on increasing the durability of the cement composite at high temperatures.

National Repository of Grey Literature : 11 records found   1 - 10next  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.