Measurement of relaxation constants by use of magnetic resonance
Kořínek, Radim ; Bartušek, Karel (referee) ; Gescheidtová, Eva (advisor)
This bachelor’s thesis is dedicated to principles of magnetic resonance and measurement of relaxation times. At theoretical part all basics methods of measurement (SE-spin echo, GE-gradient echo, SR-saturation recovery, IR- inversion recovery) of relaxation times T1, T2 resp. T2* are shown. At practical part T1 and flip angles are carefully observed. In case of measurement of relaxation time T2, the FID signal acquisition after 90° RF pulse is sufficient. T2* time is set from absorbtion line. For measurement of transversal relaxation method SE (often called as Hahn spin echo –90° RF pulse is followed by next 180° RF pulse) can be used. With GE method, the T2* relaxation is observed. Measurement of relaxation time T1 using RF impulses and inclinable angles A, is described at chapter 3. Every magnetization components during RF impulses are deeply described by mathematical formulas. Other chapter of this bachelor thesis describes some functions from MATLAB and their fitness for approximation of signal. From every tested functions, the lsqcurvefit function would be the best. Iteration method is most fitting function for approximation of FID signal.
Measurement of relaxation constants by use of magnetic resonance
Kořínek, Radim ; Bartušek, Karel (referee) ; Gescheidtová, Eva (advisor)
This bachelor’s thesis is dedicated to principles of magnetic resonance and measurement of relaxation times. At theoretical part all basics methods of measurement (SE-spin echo, GE-gradient echo, SR-saturation recovery, IR- inversion recovery) of relaxation times T1, T2 resp. T2* are shown. At practical part T1 and flip angles are carefully observed. In case of measurement of relaxation time T2, the FID signal acquisition after 90° RF pulse is sufficient. T2* time is set from absorbtion line. For measurement of transversal relaxation method SE (often called as Hahn spin echo –90° RF pulse is followed by next 180° RF pulse) can be used. With GE method, the T2* relaxation is observed. Measurement of relaxation time T1 using RF impulses and inclinable angles A, is described at chapter 3. Every magnetization components during RF impulses are deeply described by mathematical formulas. Other chapter of this bachelor thesis describes some functions from MATLAB and their fitness for approximation of signal. From every tested functions, the lsqcurvefit function would be the best. Iteration method is most fitting function for approximation of FID signal.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.