Optimization of tomographic station GE phoenix adjustment for plastic components including metal parts
Starý, Přemysl ; Petrilak, Michal (referee) ; Zikmund, Tomáš (advisor)
X-ray computed tomography is a tool mostly used in a medical diagnosis. A development of the technique and an improvement an in accuracy of tomographic systems enabled an utilization of the tomography in industrial applications. The tomography allows non-destructive analysis of inner structure. There is a negative influence of a reconstructed area if a low-absorption and high-absorption materials are scanned together. This influence makes analysis of the inner structure impossible. There are two options to eliminate these artifacts. We can use algorithms to reduce metal artifacts, or we can try to avoid them when performing the scan. This bachelor thesis focuses on an optimization of tomographic station adjustment for the plastic components including metal parts. The effect of an usage of X-ray filter or collimator and effect of a sample orientation on data quality will be observed. We use tools like contrast, noise and edge sharpness to evaluate data quality.
CT X-ray quantitative evaluation
Novotný, Lukáš ; Malínský, Miloš (referee) ; Drastich, Aleš (advisor)
X-Ray Computed Tomography is irreplaceable medical imaging system. Quantitative evaluation is day to day routine used for clean run of this imaging system. The master’s thesis is focused on quantitative evaluation of first and third generation X-Ray CT. First of all is about subjective and objective evaluation of space and energetic resolution. Space resolution is evaluated in space and frequency domain. Energetic resolution is represent by low contrast resolution method. Application “Kvantitativní hodnocení kvality CT RTG zobrazení” created for this thesis is used for creation of reconstruction image and quantitative evaluation. This application was created with consideration of its usage in subjects about image processing. The master’s thesis contains results of quantitative evaluation X-Ray CT created with this application and proposal of lab work.
CT X-ray quantitative evaluation
Novotný, Lukáš ; Malínský, Miloš (referee) ; Drastich, Aleš (advisor)
X-Ray Computed Tomography is irreplaceable medical imaging system. Quantitative evaluation is day to day routine used for clean run of this imaging system. The master’s thesis is focused on quantitative evaluation of first and third generation X-Ray CT. First of all is about subjective and objective evaluation of space and energetic resolution. Space resolution is evaluated in space and frequency domain. Energetic resolution is represent by low contrast resolution method. Application “Kvantitativní hodnocení kvality CT RTG zobrazení” created for this thesis is used for creation of reconstruction image and quantitative evaluation. This application was created with consideration of its usage in subjects about image processing. The master’s thesis contains results of quantitative evaluation X-Ray CT created with this application and proposal of lab work.
Optimization of tomographic station GE phoenix adjustment for plastic components including metal parts
Starý, Přemysl ; Petrilak, Michal (referee) ; Zikmund, Tomáš (advisor)
X-ray computed tomography is a tool mostly used in a medical diagnosis. A development of the technique and an improvement an in accuracy of tomographic systems enabled an utilization of the tomography in industrial applications. The tomography allows non-destructive analysis of inner structure. There is a negative influence of a reconstructed area if a low-absorption and high-absorption materials are scanned together. This influence makes analysis of the inner structure impossible. There are two options to eliminate these artifacts. We can use algorithms to reduce metal artifacts, or we can try to avoid them when performing the scan. This bachelor thesis focuses on an optimization of tomographic station adjustment for the plastic components including metal parts. The effect of an usage of X-ray filter or collimator and effect of a sample orientation on data quality will be observed. We use tools like contrast, noise and edge sharpness to evaluate data quality.