Primary testing of the protection relays
Macek, Vratislav ; Topolánek, David (referee) ; Toman, Petr (advisor)
The main subject of this bachelor’s thesis is the creation of laboratory task on the issue of primary injection testing of the protection relays. The thesis is made up of two parts: theoretical and practical. In theoretical part there are information concerning the issue of protecting. One of them the meaning and relay function, requirements applicable on them, failure states, which may arise on the device operation, description of instrument transformers and methods of testing relays. In practical part is created laboratory task on the issue of primary injection testing of overcurrent relay, of which will demonstrate the influence of load current transformer to its function. In task are used Overcurrent and Earth-fault protection REJ 525A and measuring instrument Omicron CPC 100.
Differential protection of transformer.
Svoboda, Miloslav ; Paar, Martin (referee) ; Toman, Petr (advisor)
This bachelor thesis is divided into several chapters, which consist of two main parts of the work, theoretical and practical. In the theoretical part the work deals with disorders of electric network, causes and limit of their adverse effects. Further it theoretically analyses the function of electrical protection, requirements for the protection , their basic elements. Then there is described the principle and function of instrument transformers and the differential protection of transformers. The practical part of the work deals with protection for a specific transformer. The proposal involves the calculation of three-phase short-circuit, the selection of differential protection, the proposal of instrument transformers and settings of the protection function.
Design of The Data Communication Between Digital Protection Relays and Monitoring System of Dukovany Nuclear Power Plant
Šula, Vladimír ; Topolánek, David (referee) ; Toman, Petr (advisor)
This thesis describes the provision of the data communication of the new protection relays via 6 kV switch gears to the electro monitoring system at the Dukovany Nuclear Power Station. These protection relays will replace the current analog protection. The replacement process will start in 2015 and will finish in 2018. Given the overall complexity of the project, this thesis deals only with the following 6 kV switch gears 9BB and 9BD. The thesis is divided into a theoretical and a practical part. The theoretical part concerns the actual consumption and output of the Dukovany Nuclear Power Station. The following chapters describe the electro monitoring system and GRAF and LOGA software programs that are closely connected with it and that were used in the practical part. The last chapter of the theoretical part deals with the actual replacement of the protection relays of the 6 kV switch gears. Also, it describes a new optical network, which will be set up at the Dukovany Nuclear Power Station as a part of the process of replacement. The segment of the practical part concerns laboratory verification of the data communication of the new protection relays. Next, it describes actions that had to be taken in order to ensure and verify correct functionality of the data communication. This part is followed up by a closely related practical activity, which describes examination and verification of the protection functions of each of the 9BB and 9BD switch gears protection relays.
The small hydroelectric power station design
Kokeš, Petr ; Pěcha, Jiří (referee) ; Matoušek, Antonín (advisor)
The thesis deals with comprehensive design of the small hydroelectric power station in the particular site. There is the site description in the first part followed by evaluation of the hydroenergetic capacity of the watercourse and description of the inlet building and piping. Building and machinery part of the turbine hall is described in the next part. The electric part of the power station is worked up to wider scope and includes hydroalternator, switchgears incl. power for self-consumption, electric protections, cabling, transformer substation and high voltage inlet line. There is a description of the control system in the next part and economical evaluation of the investment is at the end.
Testing of distance protection
Makuta, Peter ; Novotný, Jan (referee) ; Wasserbauer, Vojtěch (advisor)
This work deals with basic fault conditions in the power system. It deals with electric protections and their requirements for service in the second section. Distance protection SIPROTEC 4 7SA610, its technical parameters and main functions are introduced in this work. Testing unit OMICRON 256plus is described in the topic dealing with testing. Manuals for adjusting the distance protection SIPROTEC 4 7SA610 and OMICRON 256plus is also included in this work. Testing of distance protection SIPROTEC 4 7SA610, analysis and evaluation of the measured values are stated in the summary.
Testing of distance protection
Makuta, Peter ; Novotný, Jan (referee) ; Wasserbauer, Vojtěch (advisor)
This work deals with basic fault conditions in the power system. It deals with electric protections and their requirements for service in the second section. Distance protection SIPROTEC 4 7SA610, its technical parameters and main functions are introduced in this work. Testing unit OMICRON 256plus is described in the topic dealing with testing. Manuals for adjusting the distance protection SIPROTEC 4 7SA610 and OMICRON 256plus is also included in this work. Testing of distance protection SIPROTEC 4 7SA610, analysis and evaluation of the measured values are stated in the summary.
Primary testing of the protection relays
Macek, Vratislav ; Topolánek, David (referee) ; Toman, Petr (advisor)
The main subject of this bachelor’s thesis is the creation of laboratory task on the issue of primary injection testing of the protection relays. The thesis is made up of two parts: theoretical and practical. In theoretical part there are information concerning the issue of protecting. One of them the meaning and relay function, requirements applicable on them, failure states, which may arise on the device operation, description of instrument transformers and methods of testing relays. In practical part is created laboratory task on the issue of primary injection testing of overcurrent relay, of which will demonstrate the influence of load current transformer to its function. In task are used Overcurrent and Earth-fault protection REJ 525A and measuring instrument Omicron CPC 100.
The small hydroelectric power station design
Kokeš, Petr ; Pěcha, Jiří (referee) ; Matoušek, Antonín (advisor)
The thesis deals with comprehensive design of the small hydroelectric power station in the particular site. There is the site description in the first part followed by evaluation of the hydroenergetic capacity of the watercourse and description of the inlet building and piping. Building and machinery part of the turbine hall is described in the next part. The electric part of the power station is worked up to wider scope and includes hydroalternator, switchgears incl. power for self-consumption, electric protections, cabling, transformer substation and high voltage inlet line. There is a description of the control system in the next part and economical evaluation of the investment is at the end.
Differential protection of transformer.
Svoboda, Miloslav ; Paar, Martin (referee) ; Toman, Petr (advisor)
This bachelor thesis is divided into several chapters, which consist of two main parts of the work, theoretical and practical. In the theoretical part the work deals with disorders of electric network, causes and limit of their adverse effects. Further it theoretically analyses the function of electrical protection, requirements for the protection , their basic elements. Then there is described the principle and function of instrument transformers and the differential protection of transformers. The practical part of the work deals with protection for a specific transformer. The proposal involves the calculation of three-phase short-circuit, the selection of differential protection, the proposal of instrument transformers and settings of the protection function.
Design of The Data Communication Between Digital Protection Relays and Monitoring System of Dukovany Nuclear Power Plant
Šula, Vladimír ; Topolánek, David (referee) ; Toman, Petr (advisor)
This thesis describes the provision of the data communication of the new protection relays via 6 kV switch gears to the electro monitoring system at the Dukovany Nuclear Power Station. These protection relays will replace the current analog protection. The replacement process will start in 2015 and will finish in 2018. Given the overall complexity of the project, this thesis deals only with the following 6 kV switch gears 9BB and 9BD. The thesis is divided into a theoretical and a practical part. The theoretical part concerns the actual consumption and output of the Dukovany Nuclear Power Station. The following chapters describe the electro monitoring system and GRAF and LOGA software programs that are closely connected with it and that were used in the practical part. The last chapter of the theoretical part deals with the actual replacement of the protection relays of the 6 kV switch gears. Also, it describes a new optical network, which will be set up at the Dukovany Nuclear Power Station as a part of the process of replacement. The segment of the practical part concerns laboratory verification of the data communication of the new protection relays. Next, it describes actions that had to be taken in order to ensure and verify correct functionality of the data communication. This part is followed up by a closely related practical activity, which describes examination and verification of the protection functions of each of the 9BB and 9BD switch gears protection relays.