National Repository of Grey Literature 8 records found  Search took 0.00 seconds. 
Evaluation of MV/LV network earthing systems
Sítař, Martin ; Topolánek, David (referee) ; Kopička, Marek (advisor)
This master's thesis deals with the measurement of grounding systems in HV/LV distribution networks, which includes grounding system of distribution substation and transmission lines. Explores the issue and principles for the measurement of parameters, which are important for the protection of persons and animals in order not to touch exposed conductive part accidentally, protection of electrical machines and equipment against high fault current and dangerous surges while the correct function of the connected electrical equipment is maintained. These parameters include earth potential rise, ground resistance, soil resistivity, touch voltage, step voltage and transferred potential to the LV network. The aim of this work is the preparation, analysis and subsequent evaluation for the real measurement in practice. These earthing-system measurements were carried out at the distribution station and the concrete pole with a section disconnector. Then a numerical model of the grounding system of concrete pole was created in ANSYS. Subsequent evaluation of the results as numerical terms (comparison measurements and simulated results) and evaluation in terms of analytical (measurement results compliance with the standard) including the numerical model of the earthing system is solved in the practical part of the master's thesis.
Assessment of connectivity of the new source to the 110 kV network
Kopečný, David ; Fojtík, Martin (referee) ; Orságová, Jaroslava (advisor)
This thesis focuses on the connectivity problems of the new sources to the electrical network. The first part of the thesis deals with the description of the new source and the method of its connection to the electrical network. Furthermore, in work, there are elaborated the blocking conditions for substation TR Neratovice expanded distribution point. A distribution network operator must receive an attachment application for connecting before the actual connection. The attachments consist of study cases of conjunction that values the inverse influence on the distributional network and informs the operator about the required measures for the reliable service with the new source. PSS Sincal computer software was used to survey the inverse influences on the distributional network. Based on processed data, the evaluation of conjunction of the synchronous generator to the grid at TR Neratovice substation was reconsidered.
New Resources Connection Analysis to Power System
Galuszka, Jakub ; Ing. Pavel Štěpánek - ČEZ a.s.- EDU (referee) ; Matoušek, Antonín (advisor)
This dissertation deals with the idea of annexing a new nuclear resource in the locality of the Dukovany Nuclear Power Plant and the way of its connection to the power system. The main aim of this dissertation is to design concrete solution of the connection of the new resource to a certain point of the power system and complete this design by means of chosen calculation. According to the task, this dissertation consists of three parts. The first part describes the current engineering solution of the main one line diagram of our two existing nuclear power plants and generally of chosen types of power plants abroad, too. There is also a design of the internal consumption of the nuclear power plants. The objective of the second part of this dissertation is to present the survey of the power and dispositional variants of the new resource in view and mainly assess general possibilities of its connection. Using all information from the preceding part, the third part presents the concrete design of the engineering solution of the connection of the new resource to the power system and also the calculation of parameters of block transmission line. Another dissertation named “Study of Slavětice Distribution Substation Enlargement for EDU New Resources“ concurs this part or more precisely, my dissertation as a whole . For my dissertation I have used some materials and information from the ČEZ Corporation which are confidential. I have also used some knowledge from the analysis from the EGÚ Brno Corporation. This dissertation neither represents nor substitutes a complex analysis of all aspects of a new nuclear resource in the Dukovany Nuclear Power Plant.
Measurement of grounding system HV/LV and touch voltages around distribution transformer station
Sítař, Martin ; Topolánek, David (referee) ; Kopička, Marek (advisor)
This work deals with the measurement of earth resistance of grounding system and verification of touch voltages around outlying, suburban and urban distribution transformer stations and HV masts. When designing the grounding systems certain specific requirements for performance and safety are required. The aim is to practically verify earthing resistances at selected distribution transformer stations and HV masts of power line. Another objective of this work is assessment of the maximum possible touch voltages during fault conditions in these selected HV systems and to produce technical report which includes test results and final evaluation in compliance with valid standards.
Assessment of connectivity of the new source to the 110 kV network
Kopečný, David ; Fojtík, Martin (referee) ; Orságová, Jaroslava (advisor)
This thesis focuses on the connectivity problems of the new sources to the electrical network. The first part of the thesis deals with the description of the new source and the method of its connection to the electrical network. Furthermore, in work, there are elaborated the blocking conditions for substation TR Neratovice expanded distribution point. A distribution network operator must receive an attachment application for connecting before the actual connection. The attachments consist of study cases of conjunction that values the inverse influence on the distributional network and informs the operator about the required measures for the reliable service with the new source. PSS Sincal computer software was used to survey the inverse influences on the distributional network. Based on processed data, the evaluation of conjunction of the synchronous generator to the grid at TR Neratovice substation was reconsidered.
Evaluation of MV/LV network earthing systems
Sítař, Martin ; Topolánek, David (referee) ; Kopička, Marek (advisor)
This master's thesis deals with the measurement of grounding systems in HV/LV distribution networks, which includes grounding system of distribution substation and transmission lines. Explores the issue and principles for the measurement of parameters, which are important for the protection of persons and animals in order not to touch exposed conductive part accidentally, protection of electrical machines and equipment against high fault current and dangerous surges while the correct function of the connected electrical equipment is maintained. These parameters include earth potential rise, ground resistance, soil resistivity, touch voltage, step voltage and transferred potential to the LV network. The aim of this work is the preparation, analysis and subsequent evaluation for the real measurement in practice. These earthing-system measurements were carried out at the distribution station and the concrete pole with a section disconnector. Then a numerical model of the grounding system of concrete pole was created in ANSYS. Subsequent evaluation of the results as numerical terms (comparison measurements and simulated results) and evaluation in terms of analytical (measurement results compliance with the standard) including the numerical model of the earthing system is solved in the practical part of the master's thesis.
Measurement of grounding system HV/LV and touch voltages around distribution transformer station
Sítař, Martin ; Topolánek, David (referee) ; Kopička, Marek (advisor)
This work deals with the measurement of earth resistance of grounding system and verification of touch voltages around outlying, suburban and urban distribution transformer stations and HV masts. When designing the grounding systems certain specific requirements for performance and safety are required. The aim is to practically verify earthing resistances at selected distribution transformer stations and HV masts of power line. Another objective of this work is assessment of the maximum possible touch voltages during fault conditions in these selected HV systems and to produce technical report which includes test results and final evaluation in compliance with valid standards.
New Resources Connection Analysis to Power System
Galuszka, Jakub ; Ing. Pavel Štěpánek - ČEZ a.s.- EDU (referee) ; Matoušek, Antonín (advisor)
This dissertation deals with the idea of annexing a new nuclear resource in the locality of the Dukovany Nuclear Power Plant and the way of its connection to the power system. The main aim of this dissertation is to design concrete solution of the connection of the new resource to a certain point of the power system and complete this design by means of chosen calculation. According to the task, this dissertation consists of three parts. The first part describes the current engineering solution of the main one line diagram of our two existing nuclear power plants and generally of chosen types of power plants abroad, too. There is also a design of the internal consumption of the nuclear power plants. The objective of the second part of this dissertation is to present the survey of the power and dispositional variants of the new resource in view and mainly assess general possibilities of its connection. Using all information from the preceding part, the third part presents the concrete design of the engineering solution of the connection of the new resource to the power system and also the calculation of parameters of block transmission line. Another dissertation named “Study of Slavětice Distribution Substation Enlargement for EDU New Resources“ concurs this part or more precisely, my dissertation as a whole . For my dissertation I have used some materials and information from the ČEZ Corporation which are confidential. I have also used some knowledge from the analysis from the EGÚ Brno Corporation. This dissertation neither represents nor substitutes a complex analysis of all aspects of a new nuclear resource in the Dukovany Nuclear Power Plant.

Interested in being notified about new results for this query?