Air conditioning of the kitchen
Raftopulos, Patrik ; Jelínek, Ondřej (referee) ; Rubina, Aleš (advisor)
This bachelor's thesis deals with the ventilation system for the functional unit of the kitchen in the hospital eating facility. The theoretical part is focused on methods of limiting the leakage of sensible and bound heat from cooking technologies into the room. In the calculation part, the design of hot air heating of the functional unit is solved. The overall analysis of the building and the division into individual functional units, the calculation of the heat balance of the functional unit, pressure drops, air flows, the design of the piping and the air handling unit are also solved. All elements necessary for the proper functioning of the entire system are listed.
Ventilation of a multifunctional building
Vozák, Daniel ; Blasinski, Petr (referee) ; Uher, Pavel (advisor)
First part of bachelot’s thesis is focused on general principes of ventilation and air treatment by air – conditioning system. Second part is focused on design of air – conditioning system in second floor of multifunctional building. The main rooms and hygienic facilities for the main rooms are addressed. Heat load coverage is addressed by the air – conditioning systém, or in combination with inderect cooling or inderect cooling only. In the third part the documentation for the implementation of these designed air – conditioning systém is elaborated.
Airconditioning system of the restaurant with bowling alley
Tomeš, Adam ; Uher, Pavel (referee) ; Blasinski, Petr (advisor)
The bachelor thesis solves the design of the restaurant with a bowling alley. The aim of this work is to design two air-handling devices in the part of the given object. Individual devices are designed to meet hygienic, operational and functional requirements for the indoor microclimate of the proposed areas. The bachelor thesis is divided into three main parts: the theoretical part, the computational part and the project. The topic for the theoretical part is the requirements for VZT equipment. The computational part is practically focused on the design of two ventilation devices. The last part of the bachelor thesis is the project documentation of the airconditioning of the bowling alley.
Intensive care unit air conditioning
Dobrovolná, Natálie ; Uher, Pavel (referee) ; Rubina, Aleš (advisor)
The bachelor's thesis deals with the ventilation system serving hospital premises. The system is divided into two separate functional units. Facility No. 1 serves the ICU (Intensive Care Unit) department and its associated premises. Facility No. 2 serves the facilities of employees, doctors' rooms and associated premises. The design of the equipment meets the relevant standards, hygiene standards and operational requirements. The calculation part deals with the design of air conditioning in the ICU, it deals with the overall analysis of both functional units, heat gains, heat loss, air flows, pressure drops in both functional units and other proposals necessary for the design and proper operation of the air conditioning system. This part is also focused on the distribution and treatment of fresh air. The theoretical part deals with clean rooms, their definition and distribution of air supplied to these rooms. The theoretical part also deals with the installation of operating theaters, images of flow in these areas and their internal microclimate.
HVAC of part of the hospital department
Pěnčíková, Monika ; Rubina, Aleš (referee) ; Hirš, Jiří (advisor)
The bachelor's thesis deals with the comprehensive design of a new workplace with instrumentation, and thus also the technical equipment of part of this hospital department. It will be modernized and equipped with new, more efficient devices. The construction work will take place within the interior of the building, with the exception of the replacement of windows and the installation of an HVAC unit on the roof. The affected spaces are marked in the drawing section and contain a SPECT x-ray examination room, a control room from where employees control the necessary equipment, an entrance hall, three patient changing rooms, a toilet or a patient background and a secondary examination room. The area in question is divided into two functional units. The theoretical part is devoted to hospitals, their definitions and divisions. Subsequently, I deal with radiology and the necessary technical background for the SPECT area in question.
Air conditioning of a multifunctional building
Čížek, Vítězslav ; Uher, Pavel (referee) ; Rubina, Aleš (advisor)
This bachelor´s thesis deals with an air conditioning system that serves for warm air heating and ventilation of a multifunctional building. The systém consists of two functional units. The first part will be operated by devices no. 1, 3 a 4, which provide warm air heating and ventilation for the spaces of the playing courts. The second part will be operated by device no. 2, and will serve for warm air ventilation of the facilities for the playing courts. The theoretical part of the thesis focuses on heat recovery systems in air conditioning. In the calculation part, the thesis deals with the design of warm air heating and ventilation, as well as the overal analysis of the both functional units, including the calculation of heat losses, heat gains, air flow rate, and pressure drops. The necessary proposals for the proper functioning of the entire air conditioning system, including the distribution and conditioning of air, are provided.
Intensive care unit air conditioning
Dobrovolná, Natálie ; Uher, Pavel (referee) ; Rubina, Aleš (advisor)
The bachelor's thesis deals with the ventilation system serving hospital premises. The system is divided into two separate functional units. Facility No. 1 serves the ICU (Intensive Care Unit) department and its associated premises. Facility No. 2 serves the facilities of employees, doctors' rooms and associated premises. The design of the equipment meets the relevant standards, hygiene standards and operational requirements. The calculation part deals with the design of air conditioning in the ICU, it deals with the overall analysis of both functional units, heat gains, heat loss, air flows, pressure drops in both functional units and other proposals necessary for the design and proper operation of the air conditioning system. This part is also focused on the distribution and treatment of fresh air. The theoretical part deals with clean rooms, their definition and distribution of air supplied to these rooms. The theoretical part also deals with the installation of operating theaters, images of flow in these areas and their internal microclimate.
Ventilation of a multifunctional building
Vozák, Daniel ; Blasinski, Petr (referee) ; Uher, Pavel (advisor)
First part of bachelot’s thesis is focused on general principes of ventilation and air treatment by air – conditioning system. Second part is focused on design of air – conditioning system in second floor of multifunctional building. The main rooms and hygienic facilities for the main rooms are addressed. Heat load coverage is addressed by the air – conditioning systém, or in combination with inderect cooling or inderect cooling only. In the third part the documentation for the implementation of these designed air – conditioning systém is elaborated.
Airconditioning system of the restaurant with bowling alley
Tomeš, Adam ; Uher, Pavel (referee) ; Blasinski, Petr (advisor)
The bachelor thesis solves the design of the restaurant with a bowling alley. The aim of this work is to design two air-handling devices in the part of the given object. Individual devices are designed to meet hygienic, operational and functional requirements for the indoor microclimate of the proposed areas. The bachelor thesis is divided into three main parts: the theoretical part, the computational part and the project. The topic for the theoretical part is the requirements for VZT equipment. The computational part is practically focused on the design of two ventilation devices. The last part of the bachelor thesis is the project documentation of the airconditioning of the bowling alley.