National Repository of Grey Literature 4 records found  Search took 0.00 seconds. 
Air cooled condenser
Bochníček, Ondřej ; Kracík, Petr (referee) ; Pospíšil, Jiří (advisor)
This master´s thesis deals with an air cooled condenser. The specific attention is focused on the condenser in the Brno´s waste-to-energy plant SAKO. The general process of calculation of the heat transfer coefficient is introduced, which is the base for the calculation of the condenser´s output. This process is later used for the calculation of a specific condenser. A considerable part of the thesis is concentrated on the analysis of behavior of the condenser of SAKO in various conditions from the theoretical point of view and then also in terms of real operation using provided operational data.
Parametric study of air cooled heat exchanger
Tichý, Marek ; Toman, Filip (referee) ; Baláš, Marek (advisor)
This diploma thesis deals with air-cooled heat exchangers. Firstly, these types of heat exchangers are described theoretically in many different variations. The following part of the diploma thesis is focused on thermohydraulic calculations that aim to determine the resulting heat transfer coefficient and the necessary heat exchange surface. This calculation depends on the chosen piping and its geometry. The design of a specific heat exchanger follows the calculation, which is documented with a projection drawing. In the following section, a parametric study is conducted to investigate the dependence of heat exchanger properties on changes in its geometry.
Energy use of the facade
Salajka, Radek ; Rubinová, Olga (referee) ; Rubina, Aleš (advisor)
The main motive of this master's thesis is expanding awareness of ventilated facades and their use and comparison with external thermal insulation composite system (ETICS). I mention this in theoretical research. As an expansion to theory and a key theme of this thesis is a description of individual physical events present on the facade and in it's ventilated gap based on data output from measurement. The data gathering was made by a group of professionals who have done an on-point facade measurement on a real ventilated facade throughout a year - more detail in text. I personally have been a part of a research team and I describe my work and research in detail in the third part of this master's thesis - experimental part. In practical part I devote myself to use our new knowledge on a given building. More precisely - I use numerical calculations to present energy use of of given facade in comparison with ETICS on the same building with the same boundary conditions.
Air cooled condenser
Bochníček, Ondřej ; Kracík, Petr (referee) ; Pospíšil, Jiří (advisor)
This master´s thesis deals with an air cooled condenser. The specific attention is focused on the condenser in the Brno´s waste-to-energy plant SAKO. The general process of calculation of the heat transfer coefficient is introduced, which is the base for the calculation of the condenser´s output. This process is later used for the calculation of a specific condenser. A considerable part of the thesis is concentrated on the analysis of behavior of the condenser of SAKO in various conditions from the theoretical point of view and then also in terms of real operation using provided operational data.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.