Flow injection analysis of selected glycosaminoglycans with spectrofluorimetric detection
Tichá, Renata ; Nesměrák, Karel (advisor) ; Rychlovský, Petr (referee)
The thesis is focused on a determination of heparin and chondroitin sulfate, using flow injection analysis with spectrofluorimetric detection. The determination is based on the interaction of negatively charged heparin, chondroitin sulfate resp., with a cationic dye (azure B or phenosafranine) which is manifested by the decrease in fluorescence intensity of the dye in its emission maximum. The optimal conditions for the determination in static mode were found, and calibration dependencies were measured. The conditions of FIA were optimized and following parameters were established: the volume of dispensed sample of 100 ml, the length of the reaction coil 60 cm, the flow rate 0.7 ml min-1 , the concentration of azure B 1.6×10-5 mol dm-3 , the concentration of phenosafranine 3.5×10-5 mol dm-3 . For the determination of heparin using azure B it was found: LOD = 0.023 IU ml-1 , LOQ = 0.186 IU ml-1 , and linear dynamic range 0.19-1.43 IU ml-1 . For the determination of heparin using phenosafranine it was found: LOD = 0.102 IU ml-1 , LOQ = 0.192 IU ml-1 , and linear dynamic range 0.19-1.79 IU ml-1 . For the determination of chondroitin sulfate using azure B it was found: LOD = 0.58 mg dm-3 , LOQ = 2.37 mg dm-3 , and linear dynamic range 2.37-8.32 mg dm-3 . The developed determination was applied to the...
Flow injection analysis of selected glycosaminoglycans with spectrofluorimetric detection
Tichá, Renata ; Nesměrák, Karel (advisor) ; Rychlovský, Petr (referee)
The thesis is focused on a determination of heparin and chondroitin sulfate, using flow injection analysis with spectrofluorimetric detection. The determination is based on the interaction of negatively charged heparin, chondroitin sulfate resp., with a cationic dye (azure B or phenosafranine) which is manifested by the decrease in fluorescence intensity of the dye in its emission maximum. The optimal conditions for the determination in static mode were found, and calibration dependencies were measured. The conditions of FIA were optimized and following parameters were established: the volume of dispensed sample of 100 ml, the length of the reaction coil 60 cm, the flow rate 0.7 ml min-1 , the concentration of azure B 1.6×10-5 mol dm-3 , the concentration of phenosafranine 3.5×10-5 mol dm-3 . For the determination of heparin using azure B it was found: LOD = 0.023 IU ml-1 , LOQ = 0.186 IU ml-1 , and linear dynamic range 0.19-1.43 IU ml-1 . For the determination of heparin using phenosafranine it was found: LOD = 0.102 IU ml-1 , LOQ = 0.192 IU ml-1 , and linear dynamic range 0.19-1.79 IU ml-1 . For the determination of chondroitin sulfate using azure B it was found: LOD = 0.58 mg dm-3 , LOQ = 2.37 mg dm-3 , and linear dynamic range 2.37-8.32 mg dm-3 . The developed determination was applied to the...
Determination of heparine by SIA with spectrofluorimetric detection
Bár, Ladislav ; Rychlovský, Petr (advisor) ; Nesměrák, Karel (referee)
This thesis was focused on a determination of heparin using sequential injection analysis with spectrofluorimetric and spectrophotometric detection. The principle of determination was based on the interaction of heparin with phenothiazine dye. A decrease of fluorescence intensity of dye in its emission maximum was detected. In the case of spectrophotometric detection a decrease of the absorbance of dye was measured. Azure A, azure B and methylene blue were used as representantive selection of phenothiazine dyes. The determination was performed on a laboratory made SIA apparatus, for which a control software in LabVIEW 7.1 graphical programming was created. Two types of flow configuration for spectrofluorimetric detection were implemented. Type 1: For deionized water as a carrier stream with a injection of heparin and dye zones there were found the following optimal conditions: cdye = 1×10-5 mol dm-3 ; vflow = 2500 µl min-1 ; reaction coil length of 0 cm; injected volume of dye 150 µl and injected volume of sample 150 µl. Dynamic range of calibration curves with an exponential course for the individual dyes in the range of LOQ - 1200, eventually up 1500 IU dm-3 were detected. Limits of detection between 7.6 - 39.1 and the limits of quantification between 58.8 - 124.5 IU dm-3 were found. Type 2: For...