National Repository of Grey Literature 7 records found  Search took 0.02 seconds. 
Measurement of mechanical quantities with the support of CCD cameras
Marek, Petr ; Richter, Miloslav (referee) ; Havlíková, Marie (advisor)
This master’s work deals with types of digital cameras used in industry. Furthermore, there are mentioned application areas of cameras in the automotive industry. There was created searches industrial cameras on the market. In the next part is described hardware interconnection of Basler acA 1300-60gc camera and measuring platform cDAQ 9178. Part of this work is to create a system for synchronization of camera and measured data. In the last part is developed program for image processing and determine the angle of rotation of the steering wheel.
Inovation of system for electroluminiscence defect detection of solar cells
Lepík, Pavel ; Křivík, Petr (referee) ; Vaněk, Jiří (advisor)
This master thesis analyses the existing methods both practically and theoretically used to detect defected surface area in solar cells. Various methods were used but by using an upgraded CMOS camera without IR filter to implement the electroluminescence method, this has proven to have a very crucial impact on the results. Given the overall results and the acquired information, a procedure with a simple parameter can be setup to carry out the measurements. In addition to this a catalog was formed showing the defects occurring in mono and polycrystalline solar cells.
Light diffraction and interference in laboratory exercises
Dvořák, Tomáš ; Šicner, Jiří (referee) ; Škarvada, Pavel (advisor)
The main purpose of this semestral project is suggestion and construction the laboratory task for measuring interference and diffraction of light, which would be teached in laboratory of physics. According to gained informations about optical phenomenon, the physical construction of the laboratory task was made. Subsequently the CMOS camera was connected and installed. There was also developed a software for controlling this camera. Software is able to control all supported functions of camera, capture and save samples from live recording and show the intensity decomposition of captured images. The most important function of developed software is ability to measure distances between particular diffraction local extremes.
Usage Of Low Cost Digital Camera For Detecting Of Silicon Solar Cell Electroluminiscence
Lepík, Pavel ; Vaněk, Jiří
This article analyses the existing methods both practically and theoretically used to detect defected surface area in solar cells. Various methods were used but by using an upgraded camera with CMOS sensor for carrying out the electroluminescence method, this has proven to have a very crucial impact on the results. Given the overall results and the acquired information, a procedure with a simple parameter can be setup to carry out the measurements. In addition to this a catalog was formed showing the defects occurring in mono and polycrystalline solar cells.
Inovation of system for electroluminiscence defect detection of solar cells
Lepík, Pavel ; Křivík, Petr (referee) ; Vaněk, Jiří (advisor)
This master thesis analyses the existing methods both practically and theoretically used to detect defected surface area in solar cells. Various methods were used but by using an upgraded CMOS camera without IR filter to implement the electroluminescence method, this has proven to have a very crucial impact on the results. Given the overall results and the acquired information, a procedure with a simple parameter can be setup to carry out the measurements. In addition to this a catalog was formed showing the defects occurring in mono and polycrystalline solar cells.
Light diffraction and interference in laboratory exercises
Dvořák, Tomáš ; Šicner, Jiří (referee) ; Škarvada, Pavel (advisor)
The main purpose of this semestral project is suggestion and construction the laboratory task for measuring interference and diffraction of light, which would be teached in laboratory of physics. According to gained informations about optical phenomenon, the physical construction of the laboratory task was made. Subsequently the CMOS camera was connected and installed. There was also developed a software for controlling this camera. Software is able to control all supported functions of camera, capture and save samples from live recording and show the intensity decomposition of captured images. The most important function of developed software is ability to measure distances between particular diffraction local extremes.
Measurement of mechanical quantities with the support of CCD cameras
Marek, Petr ; Richter, Miloslav (referee) ; Havlíková, Marie (advisor)
This master’s work deals with types of digital cameras used in industry. Furthermore, there are mentioned application areas of cameras in the automotive industry. There was created searches industrial cameras on the market. In the next part is described hardware interconnection of Basler acA 1300-60gc camera and measuring platform cDAQ 9178. Part of this work is to create a system for synchronization of camera and measured data. In the last part is developed program for image processing and determine the angle of rotation of the steering wheel.