National Repository of Grey Literature 17 records found  previous11 - 17  jump to record: Search took 0.00 seconds. 
Load Flow Calculation of Chosen Part of E.ON 110kV Grid with Analysis of Reactive Power Flow
Skoupý, Martin ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
Content of this bachelor thesis is theoretic introduction to the steady state of network and optimization of network operation from the viewpoint of reducing active power losses in the electric wiring. Furthermore, the work deals with analysis of the network traffic flow distribution of the active and reactive power and consequences of overflow of the reactive power from the medium voltage level to the high voltage level. The following part includes designing practical involvement of the area and carrying out calculations of its operation in terms of losses. Another chapter is proposition of measures to minimize the overflowing of reactive power in distribution system and its impact on reduction of operating losses in the network. In the conclusion the work summarizes results obtained and the final assessment of influence of reactive power for operation of the network.
The issue of electrical equipment inspection
Polášek, Roman ; Hájek, Vítězslav (referee) ; Veselka, František (advisor)
This work is applied to questions about revision of electric equipment. Revised equipment is compensation switchboards connected with asynchronous engine. Component of the work is measurement of this equipment and consequently status evaluation in audit report. There were proposed laboratory exercise to these equipments in conclusion.
Stabilized operation of a 110 kV power line
Leinweber, Luboš ; Paar, Martin (referee) ; Blažek, Vladimír (advisor)
My work is dealing with parameters long high voltage (vvn)110kV with wanted output parameters(voltage rating , cos? , aktive power and size of power line) namely in theoretic part as well as in practic part , which I made from required parameter values of power line. At first I did the approximate calculation by reserve power lines ( T , ? , ? , Steinmetz), by short power line , idle power lines and after that I made perfect conclusion and elaboration by the help of lines. I described these kind of calculation in the theoretic part. I compared the results and I determinated which method was te best.
Utilization of local systems for power system regulation
Kostov, Jiří ; Geschwinder, Lukáš (referee) ; Bartošík, Tomáš (advisor)
Bachelor’s Thesis deals general information about methods of regulation of elektrification systems, including basic principles of regulation of frequency, regulation of voltage and regulation of reactive and active power. Work includes information about aggregate remote control system, power plants that participate on regulation and self device for regulation and controlling of reactive power. Work engages on new options in section of regulation and his requirements for distribution sites. Part of work deals information about renewable natural energy sources and his requirements for distribution sites.
Influence of Wind Farms on Electrical Energy Quality
Bartko, Jan ; Krátký,, Milan (referee) ; Malý, Jiří (advisor)
This thesis is occupied by influences of wind farms on electrical energy quality. Object of thesis was analyse influence of these power plants in a large of number. The first part was attended to presentation of wind turbines producers and their agency on worldwide and European market. At the same time were introduced new technologies of wind power generate. The second part is occupied by influence of wind farms on electrical energy quality. In this part was created model of feed system by GLF software and wind farms were connected into it. By the help of this model was run analyze of local influences of wind power plants on electrical energy quality. In last part was assessed influence of wind power plants feed system integration on electrical energy price, build and operating costs, including the prognosis to the future.
Load flow analyses of reactive power in distribution system
Krátký, Michal ; Kašpírek,, Martn (referee) ; Topolánek, David (advisor)
This thesis is focused on issues with transmission of reactive power though the distribution line of E.ON area. The goal is to find out where and in what rate are overflows of reactive power and to project the correctional steps to minimize this overflow. In this solution, there were used data of dispatcher measurement, which were processed by created source code in Matlab. The processing was analyzed for final conclusion. There were discovered shortages in overflow of reactive power in transfer between distribution and transmission line and in unsuitably regulated capacity power factor in Planá power plant and wrong automatic regulation of turns in 440/110kV substation Dasný. The action to minimize overflows of reactive power was projected by decompensation reactor placed in T101 and T102 transformers in substation Tábor.
Problems and measurements of the basic electrotechnical quantities
BOHÁČ, Radek
The purpose of this thesis is selection and specification of basic teaching methods used in heavy current laboratory during vocational training education at secondary school. Basic methods for electrical values measurements in heavy-current laboratory, measuring instruments basic division and measured electrical values evaluation. Further, basic measurement of electrical values, current, voltage, power, resistance and capacity are specified here.

National Repository of Grey Literature : 17 records found   previous11 - 17  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.