Národní úložiště šedé literatury Nalezeno 1 záznamů.  Hledání trvalo 0.01 vteřin. 

Could not find similar documents for this query.
HYDROGEN STORAGE IN Mg-In-C ALLOYS: EFFECT OF COMPOSITION AND AGEING
Čermák, Jiří ; Král, Lubomír
Hydrogen storage in two Mg-In-C alloys with different In concentration, c In , was studied in the temperature range from 250°C to 350°C after five-years-ageing at room temperature. The both alloys show acceptable cycling stability, however, the storage capacity of the alloys decreased from about 5 wt. % H2 to about 2,5 and 3.1 wt. % H 2 by higher c In and lower c In , respectively after 5 years. The sorption kinetics degraded much more by high c In than by c In . PCT isotherms, TPS and DSC patterns were measured for both materials. It was found that the hydrides responsible for hydrogen storage in alloy with higher c In are slightly more stable.

Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?