Národní úložiště šedé literatury Nalezeno 4 záznamů.  Hledání trvalo 0.00 vteřin. 
Validaton of multichannel bioimpedance of vessels using synchronized vascular ultrasonography
Hidegová, Simona ; Kolářová, Jana (oponent) ; Mézl, Martin (vedoucí práce)
The inclusion of a new device in clinical practice requires an adequate validation. The original publication which introduced multichannel bioimpedance monitor MBM was focused on discribing its technical parameters and demonstration measurements. Further evaluation desires comparision with other standard measuring device. This thesis describes pulse wave measurement by MBM and by other medical devices used for establishing cardiovascular risk. It proposes the validation experiment with synchronized vascular ultrasonography as a reference method. The process of the experimental measurement, aquired data and following data analysis are described in detail. The outputs of the experiment are statistically evaluated. The MBM’s performance and design of the experiment are discussed.
Neinvazivní měření glukózy v krvi
Vítová, Hana ; Chmelař, Milan (oponent) ; Sekora, Jiří (vedoucí práce)
Cílem této práce je prozkoumání metod neinvazivního měření glukózy spojené s návrhem neinvazivního měřicího přístroje pro stanovení koncentrace glukózy v krvi. Úvodní kapitoly práce se zabývají různými metodami měření glukózy v krvi, zejména měřením v blízké oblasti infračerveného záření (NIR) za použití spektroskopických metod. V práci je také popsána patologie nemoci diabetes mellitus, její rozdělení a metabolismus. Teoretická část práce obsahuje rešerši oblasti metod měření glukózy v krvi. Na základě dostupných poznatků je navrženo systémové schéma vhodného zařízení pro neinvazivní měření glukózy. Základním principem přístroje je měření pomocí infračervené laserové diody, rozdvojeného optického vlákna a adekvátní fotodiody. Součástí práce je i návrh desky plošných spojů. Společně s hardwarovými schématy jsou navrženy dva vývojové diagramy vyhodnocovacího a kalibračního programu, které jsou základem pro program v jazyce C#. Pro posílání naměřených dat je využívána komunikace pomocí USB sběrnice. Součástí zařízení pro neinvazivní měření je mikrokontrolér obsahující program v jazyku C, který odesílá naměřené hodnoty koncentrace do počítače. Mikrokontrolér slouží také jako přijímač dat, určují hraniční koncentrace glukózy, z počítače.
Validaton of multichannel bioimpedance of vessels using synchronized vascular ultrasonography
Hidegová, Simona ; Kolářová, Jana (oponent) ; Mézl, Martin (vedoucí práce)
The inclusion of a new device in clinical practice requires an adequate validation. The original publication which introduced multichannel bioimpedance monitor MBM was focused on discribing its technical parameters and demonstration measurements. Further evaluation desires comparision with other standard measuring device. This thesis describes pulse wave measurement by MBM and by other medical devices used for establishing cardiovascular risk. It proposes the validation experiment with synchronized vascular ultrasonography as a reference method. The process of the experimental measurement, aquired data and following data analysis are described in detail. The outputs of the experiment are statistically evaluated. The MBM’s performance and design of the experiment are discussed.
Neinvazivní měření glukózy v krvi
Vítová, Hana ; Chmelař, Milan (oponent) ; Sekora, Jiří (vedoucí práce)
Cílem této práce je prozkoumání metod neinvazivního měření glukózy spojené s návrhem neinvazivního měřicího přístroje pro stanovení koncentrace glukózy v krvi. Úvodní kapitoly práce se zabývají různými metodami měření glukózy v krvi, zejména měřením v blízké oblasti infračerveného záření (NIR) za použití spektroskopických metod. V práci je také popsána patologie nemoci diabetes mellitus, její rozdělení a metabolismus. Teoretická část práce obsahuje rešerši oblasti metod měření glukózy v krvi. Na základě dostupných poznatků je navrženo systémové schéma vhodného zařízení pro neinvazivní měření glukózy. Základním principem přístroje je měření pomocí infračervené laserové diody, rozdvojeného optického vlákna a adekvátní fotodiody. Součástí práce je i návrh desky plošných spojů. Společně s hardwarovými schématy jsou navrženy dva vývojové diagramy vyhodnocovacího a kalibračního programu, které jsou základem pro program v jazyce C#. Pro posílání naměřených dat je využívána komunikace pomocí USB sběrnice. Součástí zařízení pro neinvazivní měření je mikrokontrolér obsahující program v jazyku C, který odesílá naměřené hodnoty koncentrace do počítače. Mikrokontrolér slouží také jako přijímač dat, určují hraniční koncentrace glukózy, z počítače.

Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.