Národní úložiště šedé literatury Nalezeno 6 záznamů.  Hledání trvalo 0.01 vteřin. 
Ebulliometric and Static Measurement of Total Pressure in the in the Binary Water + Poly(Ethylene Glycol) System.
Pavlíček, Jan ; Bogdanić, Grozdana ; Wichterle, Ivan ; Izák, Pavel
The total pressure of the systems containing water and three different poly(ethylene glycol)s with nominal molecular weights of 1000, 3000 and 6000 g mol-1 was measured isothermally at 303.15, 308.15, 313.15, 323.15, 333.15, 343.15, 353.15 and 363.15, using the improved static apparatus for lower temperatures and ebulliometrically for higher temperatures, covering the concentration range up to 50 wt % of the polymer. The 343.15 K isotherm was measured by both experimental methods, and both showed good continuity and performance. A lot of additional data have been measured but not yet published, which are integrated here together with our recent measurement.
An Improved Apparatus for Vapor–liquid Equilibria Measurement in Systems Containing Polymer at Higher Temperatures.
Pavlíček, Jan ; Bogdanić, Grozdana ; Wichterle, Ivan
The apparatus for total pressure measurement in polymer + solvent systems has been designed recently. In the presented work, the range of functioning of this apparatus was extended to allow investigations at higher temperatures. A direct capacitance pressure sensor (Baratron) was replaced by a pressure transducer, which may be heated up to 200 oC. In addition, the solutions with higher concentrations of polymer can be studied in contrast to the ebulliometric method, which is limited because of problems with physical boiling of viscous mixtures.
Pittfalls in Vapor-liquid Equilibrium Simulations: Reliability of Published Data.
Nezbeda, Ivo
A simple and straightforward method is proposed for quality evaluation of simulation data of vapor-liquid equilibrium.
Simple Equipment for Measurement of Total Pressure Tested on Poly(ethylene glycol) + Water System.
Pavlíček, Jan ; Bogdanić, Grozdana ; Wichterle, Ivan
In this work, new equipment designed for total pressure determination in mixtures where one of component is not volatile, such as polymer + solvent systems, is presented. It enables measurement of pressure above solutions in a wider concentration range. The equipment has been tested and calibrated using vapour pressure of pure water. It consist of thermostat with temperature measurement (AΣΛ, model F250), 100 ml vessel for solution with magnetic stirrer with a very strong driver, and of heated manifold for charging, degassing and for pressure measurement. Pressure is measured with use of absolute heated capacitance unit MKS Baratron (pressure range 1000 Torr = 133 kPa). Mixtures were prepared by weighing to obtain volume of 50 ml, approx.
Plný tet: SKMBT_C22016090211390 - Stáhnout plný textPDF
Plný text: content.csg - Stáhnout plný textPDF
Experimentální termodynamika fázových rovnovah - quo vadis?
Wichterle, Ivan
Plný tet: SKMBT_C22015111813010 - Stáhnout plný textPDF
Plný text: content.csg - Stáhnout plný textPDF

Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.