Evaluation of possibilities for connection of wind farm Drahany 45 MW to 110 kV network
Gregr, Tomáš ; Opat, Jaroslav (referee) ; Topolánek, David (advisor)
This Master's thesis is focused on connecting of new power sources into electrical network, particularly, the steady state and allowed voltage variation in network nodes, which occur in steady state before and after connection of a new power source into distribution network, with regard to valid legislation. The new power source in question is the new wind farm Drahany with active power of 45 MW, which should be connected into distribution network 110kV, operated by distribution company E.ON. The aim of this work is to find the most suitable connection point of a wind farm into distribution network, considering transmission capacity of individual electric lines and voltage variations in network nodes, as well as Drahany wind farm's investor's expenses on construction of a connection line to connection point and the distribution network's operator's expenses on modification of the connection point. Also, methods of calculating of electric networks in steady state are described in this paper, particularly, linear calculations, because these are needed for the calculations in E-vlivy program, in which the possible options of Drahany wind farm's connection into network 110 kV, in various places, were modeled. The description of the E-Vlivy program is also included in this paper. The E.ON company's materials form the basis for this Master's thesis, which will later serve as one of the documents needed for Drahany wind farm’s connection point evaluation into distribution network 110 kV.
Steady state and short-circuit conditions within E.ON 110 kV power network at parallel operation of nodal areas of Otrokovice substation and Sokolnice substation
Mikulinec, René ; Janda, Petr (referee) ; Blažek, Vladimír (advisor)
This thesis deals with the steady operation and short-circuit conditions in the 110 kV network E.ON in a separate and parallel operation of nodal areas of Otrokovice substation and Sokolnice substation. The theoretical part is devoted to the calculation of steady state high-voltage systems using Newton's iterative method, transient phenomena that may occur in the power system short-circuit calculations and theories. The practical part deals with the actual calculations of steady state and short-circuit conditions in a separate and parallel operation of nodal areas Sokolnice-Otrokovice, which were calculated using the dispatching program. These calculations are then evaluated for possible use of involvement in actual operation. At the end there are suggestions on operational measures in the network 110 kV.
Design of the expansion of 22kV distribution network in a specific area
Řehoř, Jiří ; Beneš, Jan (referee) ; Blažek, Vladimír (advisor)
The aim of this work is the reconstruction and development of the distribution network of DS to ensure electricity supply in the required quality to existing customers and new customers connecting to the planned industrial zone Šlapanice. The first part deals with the inclusion of a distribution network in power system, its distribution and composition. Subsequently, the work deals with the description of the management of distribution networks, cable and outdoor leadership and their parameters. It also contains guidelines for the design of high voltage networks. The end of the first part is devoted to calculating the steady operation of the network. In the second part, the proposed project using the PAS DAISY Off-line v 4.00 Bizon. Based on the available evidence is developed steady state operation. We found that lines are overloaded and need to be strengthened with regard to the development of industrial zones and adjusting the network to ensure safe and reliable operation. The conclusion focuses on the economic evaluation of proposed alternatives.
Stabilized operation and short-circuit conditions within E.ON 110kV power network supplied from Otrokovice 110kV switching station, during the period of 2012
Kuba, Petr ; Rampl, Martin (referee) ; Blažek, Vladimír (advisor)
This thesis deals with steady running and short-circuit conditions in the 110 kV network, E. ON, fed from 110 kV Otrokovice. Substation Otrokovice ensures system transformation from 400 kV to 110 kV system through three transformers. In order to increase reliability of power supply and improved economy is considered to bridge the transition from the operation of two transformers in bridge operations of the three transformers. However, this brings with it significant worsening of short-circuit conditions in the 110 kV network. The task of this work is to evaluate and compare the two variants of operation in terms of steady running and short-circuit conditions in the network at 110 kV and then implement operational and technical measures. The introduction describes the electricity system and its parts. The theoretical part of the paper discusses ways of dealing with steady running and short circuit conditions of long lines. Practical part will deal with applications of knowledge on the network. The conclusion summarizes the most relevant information and the results assessed both variants.
Steady state and short-circuit conditions within E.ON 110kV power network at bridge operation of transformers T402 and T403 in 400/100kV transformer station Sokolnice
Bernát, Jan ; Rampl, Martin (referee) ; Blažek, Vladimír (advisor)
The master’s thesis deals with a calculation of steady state and short-circuit conditions in a 110 kV system during a bridge operation of transformers in a Sokolnice substation. The theoretical part of the thesis deals with a calculation of steady state of a system using Newton’s iterative method, it investigates short-circuits – their timing, distinctive values and a method of their calculation. In the practical part the 100 kV grid supplied from Sokolnice substation is described. The main goal of the thesis is a comparation of two basic wirings: bridge operation of T202 and T203 transformers (contemporarily in service) and bridge operation of T402 and T403 (in service after 2017). These two wirings were controlled even during one state of emergency during which the Sokolnice substation will be affected by an outage of one busbar. Voltage conditions, loading of power line and transformers and overall power balance were controlled. Short-circuit conditions were also calculated and short-circuit resistance of particular substations was inspected. In the conclusion technical measures needed to ensure smooth bridge operation of convertors T402 and T403.
Steady state and short-circuit conditions in 110kV E.ON network fed from Čebín transformer station
Krutiš, Petr ; Janda, Petr (referee) ; Blažek, Vladimír (advisor)
Master’s thesis deals with computation of steady state and short-circuit conditions in 110 kV nodal area of Čebín. The first part of thesis is theoretical. There is described computation of steady state and short-circuit conditions. There is description of 110 kV nodal area of Čebín too. There are made computations in the practical part. Two types of operation of transformers T401 and T402 are evaluated. The transformers operate independent at first, then they are connected in parallel. Voltage conditions in substations, load of lines and transformers, power losses and short-circuit resistance of substations in 110 kV nodal area of Čebín are evaluated based on the computations. There are compared the both types of operation of transformers in the end of practical part.
Feeding power out of 110/22 kV Moravany u Brna substation
Chromík, Aleš ; Beneš, Jan (referee) ; Blažek, Vladimír (advisor)
The aim of this Master’s thesis is the design and reconstruction of the high voltage distribution network for the company E. ON with focus on calculation of the stabilized operation and on the planning of new cable taps from the transformer substation Moravany u Brna. The first part of the theoretical analysis of the work deals with the inclusion of the distribution network into the power system and with principles of development and construction of high voltage networks. The second part includes a general calculation of stabilized operation of the power distribution network and a familiarization with the program PAS Off - Line Bison 4.0. The practical part of the thesis is focused on the calculation of the stabilized operation at the current state of transformer substation Moravany u Brna using the PAS Off - Line Bizon 4.0 V programme. This part also contains the design of six new cable lines which are needed to strengthen the power distribution in the southern part of the city Brno. The closing part of this chapter constitutes of a outdoor and indoor cable line renovation. These cables are connected to the transformer substation Moravany u Brna and a calculation of stabilized operation is also included in this part.
Steady state and short-circuit conditions within E.ON 110kV power network at parallel operation of transformers T403 and T402 in 400/100kV transformer stations Sokolnice and Otrokovice
Doležal, Marek ; Foltýn,, Daniel (referee) ; Blažek, Vladimír (advisor)
This master’s thesis is divided into two logical parts. The first part contains theory of calculation of steady state and short-circuits conditions within 110 kV distribution network. Newton’s method and short-circuit current calculation is also explained here. It also deals with classification and aftereffects of transient performance occurring in power networks. The second part contains practical calculation of steady flow and short-circuit conditions at parallel operation of transformers T403 and T402 in 400/110 kV transformer stations Sokolnice and Otrokovice. This calculation is done with program used by system operators called SINAUT Spectrum and consequently analyzed. This part also contains brief description of substations from this region.
Power Losses Calculation Depending on Distribution Network Configuration
Domes, František ; Souček, Jan (referee) ; Paar, Martin (advisor)
This master‘s thesis deals with the calculation of losses depending on the configuration of the distribution network. The first part focuses on the general theory regarding some used calculation methods of steady operation. The next part is theoreticly dedicated to the technical losses, possibilities of their influencing and their calculation. In the practical part is carried out the choice of calculation method of steady operation. This method is implicated into the proposed program in programming environment MATLAB.Furthermore, on the basis of a partial measurement in the distribution network and using the proposed program are determined the sizes of offtakes of mesh network. For the existing mesh network is designed its radial operation. In the last part are calculated the losses of this network for both of these mentioned operations.
Proposal of the reconstruction of the distribution network in a specific area
Novák, Vojtěch ; Mrvová, Dana (referee) ; Blažek, Vladimír (advisor)
This diploma thesis is concerned with reconstruction of distribution network in Hruba Vrbka. The diploma thesis is divided in two parts. For better understanding to this issue, the first theoretical part is shortly dedicated to the history of electrical power system, to the several types of distribution network of low voltage and high voltage and their utilization in the area, considering the reliability and the quality of delivery of the electric energy. In this thesis there is mentioned division of distribution grids according to placing of cable lines, according to voltage and according to type of grid connection. Next part of this work is dedicated to the description of overhead lines and cable lines and their characteristics. For the proper concept of the grid we should know some characteristics of the electric line’s proposal: mechanical strength, warming, voltage drop, efficiency, degree of safety and provision of delivery. In the end of the theoretical part there are described methods for calculation of grid’s steady state as a linear task and also non-linear task, elimination of the balancing node, the iterative method, the reduction of external power take-off nodes and the solution of the steady state of the network through the direct current model. The second part of the diploma thesis is concerned with the calculation of the steady state in the village Hruba Vrbka. In this part is also described the KASI program which was used for the calculation of the grid’s steady state. Firstly low voltage grid’s balance in Hruba Vrbka was found out and evaluated and then there were proposed some solutions of the reconstruction for the grid improving. The suggested options of the reconstruction are considered from technical and economical point of view and the best solution is chosen. For this solution there is suggested the protection through program SICHR 9. In the end of this diploma thesis there is checked the load of the high voltage line.