Diagnostics of medium voltage and high voltage circuit breakers
Kapalla, Alexej ; Šimek, David (referee) ; Dostál, Lukáš (advisor)
This bachelor work is focused on medium-voltage and high-voltage circuit breakers and their diagnostics. The thesis presents the history of HV circuit breakers and their main division. Subsequently, the relevant standards are listed in the work and diagnostics of the MV circuit breaker VD4 and the HV circuit breaker S1-245 from AEG is performed. In case of the VD4 circuit breaker, a new and used circuit breaker was diagnosed. The measured values are then compared and the impact of usage is shown. The work describes the measurement of main contact resistance, insulation resistance, closing and opening times and vacuum quality.
High-Voltage Structures for Galvanic Isolation in Integrated Circuits
Ptáček, Karel ; Husák, Miroslav (referee) ; Zemánek, Miroslav (referee) ; Boušek, Jaroslav (advisor)
Tato dizertační práce představuje novou techniku laterární rezonanční vazby, která je využita v návrhu galvanicky izolovaného posouvače úrovně, který je následně implementován v 800 V půlmůstkovém kontroléru pro průmyslové aplikace. Ve srovnání s tradičními galvanickými izolátory jsou výrobní náklady tohoto řešení nižší. Pro aplikace vyžadující vyšší úroveň galvanické izolace je popsán následný vývoj galvanicky izolovaného posouvače úrovně, který využívá pouze jeden galvanicky oddělený posouvač úrovní pro komunikaci v obou směrech, což výrazně snižuje plochu struktury izolátoru. Jako součást následného návrhu je představen galvanický izolátor který je schopen přenášet analogovou hodnotu napětí. Analogový izolátor byl testován v reálné aplikaci síťového spínaného zdroje jako náhrada standardního optočlenu. Tato konstrukce umožňuje integraci primárních a sekundárních obvodů v jednom pouzdře, což umožní snížit složitost a cenu spínaného zdroje.
The Development of High Frequency High Voltage Test Sources
Talaš, Pavel ; Bartošík, Tomáš (referee) ; Krbal, Michal (advisor)
This Bachelor´s thesis deals with the high frequency source of high voltage. This thesis is divided into two parts. The first part deals with high voltage sources for the historical site, supplemented by basic characteristics. Special attention is paid to TC (Tesla Coil). In the second part is made mathematical concept of a Tesla coil.
Feeding power out of 110/22 kV Moravany u Brna substation
Chromík, Aleš ; Beneš, Jan (referee) ; Blažek, Vladimír (advisor)
The aim of this Master’s thesis is the design and reconstruction of the high voltage distribution network for the company E. ON with focus on calculation of the stabilized operation and on the planning of new cable taps from the transformer substation Moravany u Brna. The first part of the theoretical analysis of the work deals with the inclusion of the distribution network into the power system and with principles of development and construction of high voltage networks. The second part includes a general calculation of stabilized operation of the power distribution network and a familiarization with the program PAS Off - Line Bison 4.0. The practical part of the thesis is focused on the calculation of the stabilized operation at the current state of transformer substation Moravany u Brna using the PAS Off - Line Bizon 4.0 V programme. This part also contains the design of six new cable lines which are needed to strengthen the power distribution in the southern part of the city Brno. The closing part of this chapter constitutes of a outdoor and indoor cable line renovation. These cables are connected to the transformer substation Moravany u Brna and a calculation of stabilized operation is also included in this part.
Voltage tests under wet condition
Vondrák, Michal ; Štěpánek, Jaroslav (referee) ; Krbal, Michal (advisor)
The main objective of presented thesis is to design a shower system in order to extend voltage tests by voltage wet testing. The introduction focuses on important aspects related to voltage wet testing. Such aspects originates mainly from Czech but also foreign standards. Following part of the thesis deals with specific wet testing design proposals, which fulfil the standards requirements. The final part of presented thesis is focused on partial experiments. Namely the analysis of rain water properties, behavior of rain drops exiting the nozzle with varying flow and nozzle angle, wet test on insulator in dry and wet conditions.
Proposal of the reconstruction of the distribution network in a specific area
Novák, Vojtěch ; Mrvová, Dana (referee) ; Blažek, Vladimír (advisor)
This diploma thesis is concerned with reconstruction of distribution network in Hruba Vrbka. The diploma thesis is divided in two parts. For better understanding to this issue, the first theoretical part is shortly dedicated to the history of electrical power system, to the several types of distribution network of low voltage and high voltage and their utilization in the area, considering the reliability and the quality of delivery of the electric energy. In this thesis there is mentioned division of distribution grids according to placing of cable lines, according to voltage and according to type of grid connection. Next part of this work is dedicated to the description of overhead lines and cable lines and their characteristics. For the proper concept of the grid we should know some characteristics of the electric line’s proposal: mechanical strength, warming, voltage drop, efficiency, degree of safety and provision of delivery. In the end of the theoretical part there are described methods for calculation of grid’s steady state as a linear task and also non-linear task, elimination of the balancing node, the iterative method, the reduction of external power take-off nodes and the solution of the steady state of the network through the direct current model. The second part of the diploma thesis is concerned with the calculation of the steady state in the village Hruba Vrbka. In this part is also described the KASI program which was used for the calculation of the grid’s steady state. Firstly low voltage grid’s balance in Hruba Vrbka was found out and evaluated and then there were proposed some solutions of the reconstruction for the grid improving. The suggested options of the reconstruction are considered from technical and economical point of view and the best solution is chosen. For this solution there is suggested the protection through program SICHR 9. In the end of this diploma thesis there is checked the load of the high voltage line.
Utilization of local systems for power system regulation
Kostov, Jiří ; Geschwinder, Lukáš (referee) ; Bartošík, Tomáš (advisor)
Bachelor’s Thesis deals general information about methods of regulation of elektrification systems, including basic principles of regulation of frequency, regulation of voltage and regulation of reactive and active power. Work includes information about aggregate remote control system, power plants that participate on regulation and self device for regulation and controlling of reactive power. Work engages on new options in section of regulation and his requirements for distribution sites. Part of work deals information about renewable natural energy sources and his requirements for distribution sites.
Distribution Network Development and Configuration
Pospíšil, Petr ; Beneš, Jan (referee) ; Topolánek, David (advisor)
The theme of this master‘s thesis is distribution network development and configuration in the part of Brno – Trnitá. There is expected to be investments there in the next few years. The thesis consists of two parts. For better understanding of this problem, the first theoretical part concerns with the description of electrical network (subdivision in accordance with voltage levels, conductor types, network types and other electrical network parts), solution of grid’s steady state (as a linear task and also non-linear task, elimination of the balancing node, the iterative method) and Brno distribution network characteristics. The second part concerns with distribution network development and configuration depending on anticipated load development in Trnitá. The result is proposal for transformer station construction Opuštěná fitted with three transformers of nominal output SN = 40 MVA and network configuration change required both for providing new consumption supply as well as sustaining current one.
Design and optimization of laboratory HV models
Kočí, Zbyněk ; Vyčítal, Václav (referee) ; Varmuža, Jan (advisor)
Bachelor's thesis is focuses on the operation of the distribution system in the Czech Republic and the use of new types of cables in the world. It describes the characteristics, division and use of overhead lines and cable lines. This work also deals the division and control DC networks, their advantages and disadvantages. In superconducting cables is engaged in their development, advantages and disadvantages. Describes their application and use in the future. It also describes the parameters affecting the properties of the ropes and the cables of the AC and DC wiring and ways to mitigate the negative effects on the ropes and on the surrounding environment. Work deals with measurement and counting of the laboratory models for their optimization. Finally, the work describes a proposal of new laboratory model for the measurement and stating components, which are needed for optimization models and the production of a new model
Technical modification design of the electrical power systems for Modřice and its surroundings
Šerý, Petr ; Kopička, Marek (referee) ; Ptáček, Michal (advisor)
ABSTRACT This thesis is concerned with a technical modification of design of the electrical power systems for Modřice and its surroundings. The thesis describes a basic theoretical distribution of the electricity network and the distribution network itself. Following chapters are devoted to the development and construction of the HV networks and to the methods and ways of calculating the steady operation of the network. These methods are then used in the computational programs that are presented in the next chapter of this paper. The aim of the practical part of the thesis is to first determine the current state of the network in the given location. Furthermore, several modifications are proposed according to the requirements for increasing the power consumption or connecting the new supply places. The proposed modifications are further assessed for the different operating conditions. The result is a network that is functional, operational and reliable. The whole analysis is carried out in the PAS DAISY Off-line V4 Bizon computing program.