National Repository of Grey Literature 3 records found  Search took 0.00 seconds. 
Seismic performance of timber frames
Pospíšil, Stanislav ; Urushadze, Shota ; Koleš, Jan
A series of dynamic experiments was performed on one-story timber frame. In comparison with the previous frames [1, 2], improved connection between column and girder was used here. The tests included sinusoidal sweeps in two directions, arbitrary signals simulation earthquake loads in three directions, and snapback tests. Various parameters were measured, for example tension on columns and slabs, rotation between columns and beams, displacement of columns and acceleration of columns and beams. All these parameters lead to classification of the frame behavior with designed type of connection, for example the natural frequencies, eigenmodes and other dynamical properties of the structure. Parameter description will allow us to design and improve mathematical model of the timber frame.
Cyclic loading of Adobe walls and its anti seismic strengthening reinforcement
Wünsche, Martin ; Hračov, Stanislav ; Pospíšil, Stanislav ; Urushadze, Shota
The damage of adobe masonry walls is one of the most widespread harming injuries and cause of loss of serviceability and seismic capacity for a building. The retrofitting approach is constrained by conservation requirements of minimum interventions which should not severely change the structural behavior and the structural appearance, and should prefer solutions without a necessity of total structural disassembling. This contribution an overview about the research that led to applications of the steel wire ropes and geo-nets onto adobe brick walls provides
Investigation of composite material degradation indicators using acoustic measurement: comparison with laser vibrometry
Fíla, Tomáš ; Urushadze, Shota ; Kytýř, Daniel ; Valach, Jaroslav ; Šperl, Martin
This paper deals with investigation of acoustic material degradation indicator (attenuation decrement drop of selected natural frequency) measured by a custom-built experimental device. Samples of C/PPS fibre composite material were analyzed. Acoustic signals were recorded and processed using spectral analysis and sound signal regression. Data measured by this method were verified by comparative experiment. Specimens were simultaneously measured using both acoustic experimental device and laser vibrometer. Modal analysis of the specimen were carried out prior to the experiment. This enabled assessment of specimens natural modes and therefore the best impact zone. In total, 10 measurements were performed for each specimen at the same level of degradation. Measured data were then processed and compared. The specimens were repetitively measured after designated number of loading cycles.

Interested in being notified about new results for this query?