Národní úložiště šedé literatury Nalezeno 4 záznamů.  Hledání trvalo 0.00 vteřin. 
Effect of Light Source Position on Operating Parameters
Múdry, Peter ; Krbal, Michal (oponent) ; Baxant, Petr (vedoucí práce)
The main task of this bachelor’s thesis is to find out, how does the working position of light source influence the lighting parameters of light source and possibly other closely related variables as temperature of light source etc. Purpose of this work is to measure luminous flux of some selected light sources’, where significant influence on luminous flux caused by working position of source can be expected and to process measured results. This work processes: lighting parameters of light sources’, theoretical information about influence of temperature and position on operating parameters of light sources, optimal working conditions of light sources and deals with electrical discharge in lightings.
Ustálený chod a zkratové poměry v síti 110 kV E.ON při paralelním provozu uzlových oblastí R Čebín a R Sokolnice
Múdry, Peter ; Rampl, Martin (oponent) ; Blažek, Vladimír (vedoucí práce)
V súčasnosti v distribučnej sieti 110 kV spoločnosti E.ON je uzlová oblasť rozvodni Čebín a rozvodni Sokolnice prevádzkovaná samostatne. Na kaţdú uzlovú oblasť pripadá jeden napájací transformátor 400/110 kV. V prípade akejkoľvek poruchy na jednom z transformátorov prípadne na prípojnici do ktorej daný transformátor pracuje, dôjde k výpadku dodávky elektrickej energie v danej uzlovej oblasti. Tento problém má byť vyriešený za pomoci paralelnej prevádzky uzlovej oblasti rozvodni Čebín a rozvodni Sokolnice. Hlavnou a tieţ praktickou úlohou tejto práce je navrhnúť tzv. mostíkové zapojenie vhodné pre paralelnú prevádzku uzlových oblastí (napájacích transformátorov 400/110 kV). Pre samostatnú a paralelnú prevádzku uzlových oblastí sú pomocou výpočtového programu prevedené výpočty ustáleného chodu a skratových pomerov v distribučnej sieti 110 kV. Z výpočtov ustáleného chodu sú vyhodnocované a kontrolované napäťové pomery v rozvodniach 110 kV, zaťaţenie transformátorov (400/110 kV a 110/vn kV) a pomery na vedeniach 110 kV. Na základe skratových pomerov sú kontrolované skratové odolnosti rozvodní. Na záver sú porovnané výhody a nevýhody samostatnej respektíve paralelnej prevádzky uzlových oblastí. Ak je potrebné, sú navrhnuté technické opatrenia nevyhnutné pre zavedenie paralelnej prevádzky uzlovej oblasti Čebín a uzlovej oblasti Sokolnice. Teoretická časť práce sa zaoberá výpočtom ustáleného chodu pomocou iteračných metód a to Newtonovej a Gauss-Seidlovej metódy. Ďalej je popísaná metóda výpočtu skratových prúdov, charakteristické hodnoty a časové priebehy skratového prúdu.
Effect of Light Source Position on Operating Parameters
Múdry, Peter ; Krbal, Michal (oponent) ; Baxant, Petr (vedoucí práce)
The main task of this bachelor’s thesis is to find out, how does the working position of light source influence the lighting parameters of light source and possibly other closely related variables as temperature of light source etc. Purpose of this work is to measure luminous flux of some selected light sources’, where significant influence on luminous flux caused by working position of source can be expected and to process measured results. This work processes: lighting parameters of light sources’, theoretical information about influence of temperature and position on operating parameters of light sources, optimal working conditions of light sources and deals with electrical discharge in lightings.
Ustálený chod a zkratové poměry v síti 110 kV E.ON při paralelním provozu uzlových oblastí R Čebín a R Sokolnice
Múdry, Peter ; Rampl, Martin (oponent) ; Blažek, Vladimír (vedoucí práce)
V súčasnosti v distribučnej sieti 110 kV spoločnosti E.ON je uzlová oblasť rozvodni Čebín a rozvodni Sokolnice prevádzkovaná samostatne. Na kaţdú uzlovú oblasť pripadá jeden napájací transformátor 400/110 kV. V prípade akejkoľvek poruchy na jednom z transformátorov prípadne na prípojnici do ktorej daný transformátor pracuje, dôjde k výpadku dodávky elektrickej energie v danej uzlovej oblasti. Tento problém má byť vyriešený za pomoci paralelnej prevádzky uzlovej oblasti rozvodni Čebín a rozvodni Sokolnice. Hlavnou a tieţ praktickou úlohou tejto práce je navrhnúť tzv. mostíkové zapojenie vhodné pre paralelnú prevádzku uzlových oblastí (napájacích transformátorov 400/110 kV). Pre samostatnú a paralelnú prevádzku uzlových oblastí sú pomocou výpočtového programu prevedené výpočty ustáleného chodu a skratových pomerov v distribučnej sieti 110 kV. Z výpočtov ustáleného chodu sú vyhodnocované a kontrolované napäťové pomery v rozvodniach 110 kV, zaťaţenie transformátorov (400/110 kV a 110/vn kV) a pomery na vedeniach 110 kV. Na základe skratových pomerov sú kontrolované skratové odolnosti rozvodní. Na záver sú porovnané výhody a nevýhody samostatnej respektíve paralelnej prevádzky uzlových oblastí. Ak je potrebné, sú navrhnuté technické opatrenia nevyhnutné pre zavedenie paralelnej prevádzky uzlovej oblasti Čebín a uzlovej oblasti Sokolnice. Teoretická časť práce sa zaoberá výpočtom ustáleného chodu pomocou iteračných metód a to Newtonovej a Gauss-Seidlovej metódy. Ďalej je popísaná metóda výpočtu skratových prúdov, charakteristické hodnoty a časové priebehy skratového prúdu.

Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.