National Repository of Grey Literature 22 records found  1 - 10nextend  jump to record: Search took 0.00 seconds. 
Evaluation of MV/LV network earthing systems
Sítař, Martin ; Topolánek, David (referee) ; Kopička, Marek (advisor)
This master's thesis deals with the measurement of grounding systems in HV/LV distribution networks, which includes grounding system of distribution substation and transmission lines. Explores the issue and principles for the measurement of parameters, which are important for the protection of persons and animals in order not to touch exposed conductive part accidentally, protection of electrical machines and equipment against high fault current and dangerous surges while the correct function of the connected electrical equipment is maintained. These parameters include earth potential rise, ground resistance, soil resistivity, touch voltage, step voltage and transferred potential to the LV network. The aim of this work is the preparation, analysis and subsequent evaluation for the real measurement in practice. These earthing-system measurements were carried out at the distribution station and the concrete pole with a section disconnector. Then a numerical model of the grounding system of concrete pole was created in ANSYS. Subsequent evaluation of the results as numerical terms (comparison measurements and simulated results) and evaluation in terms of analytical (measurement results compliance with the standard) including the numerical model of the earthing system is solved in the practical part of the master's thesis.
Measurement of grounding system HV/LV and touch voltages around distribution transformer station
Sítař, Martin ; Topolánek, David (referee) ; Kopička, Marek (advisor)
This work deals with the measurement of earth resistance of grounding system and verification of touch voltages around outlying, suburban and urban distribution transformer stations and HV masts. When designing the grounding systems certain specific requirements for performance and safety are required. The aim is to practically verify earthing resistances at selected distribution transformer stations and HV masts of power line. Another objective of this work is assessment of the maximum possible touch voltages during fault conditions in these selected HV systems and to produce technical report which includes test results and final evaluation in compliance with valid standards.
Interest Rate Models - Practical Aspects
Hakala, Michal ; Janeček, Martin (advisor) ; Sitař, Milan (referee)
Topic of the master thesis is practice of interest rate models. Literature dedicated to the interest rate models usually presents theory in very general form. Theory presented in general form leads to a gap between theory and practice. Author tries to fill this gap. Thesis describes basic theory and presents practical computations, which are relevant to generating interest rate scenarios. Contribution is given by derivation of formulas and computational methods in form directly applicable for implementation of presented models. It is common practice to validate quality of interest rate scenarios. Author presents several tests and implements them in programming language Python. Tests are implemented as application with graphical user interface.
Evaluation of MV/LV network earthing systems
Sítař, Martin ; Topolánek, David (referee) ; Kopička, Marek (advisor)
This master's thesis deals with the measurement of grounding systems in HV/LV distribution networks, which includes grounding system of distribution substation and transmission lines. Explores the issue and principles for the measurement of parameters, which are important for the protection of persons and animals in order not to touch exposed conductive part accidentally, protection of electrical machines and equipment against high fault current and dangerous surges while the correct function of the connected electrical equipment is maintained. These parameters include earth potential rise, ground resistance, soil resistivity, touch voltage, step voltage and transferred potential to the LV network. The aim of this work is the preparation, analysis and subsequent evaluation for the real measurement in practice. These earthing-system measurements were carried out at the distribution station and the concrete pole with a section disconnector. Then a numerical model of the grounding system of concrete pole was created in ANSYS. Subsequent evaluation of the results as numerical terms (comparison measurements and simulated results) and evaluation in terms of analytical (measurement results compliance with the standard) including the numerical model of the earthing system is solved in the practical part of the master's thesis.

National Repository of Grey Literature : 22 records found   1 - 10nextend  jump to record:
See also: similar author names
5 Sitař, Milan
1 Sitár, Michal
4 Sítař, Martin
Interested in being notified about new results for this query?
Subscribe to the RSS feed.