Static verification and variant design of roof structure of winter sport stadium in Jihlava city
Bulíček, Radek ; Melcher, Jindřich (referee) ; Karmazínová, Marcela (advisor)
The aim of the thesis is the assessment of steel structure roofing winter stadium in Jihlava city and design of the variant solution of load bearing steel structure of the roof. The ground plan dimensions are 60 x 84 m The current structure is composite of truss main girders with parabolic lower chords, and purlins . Axial distances of main girders are 12 m and are supported on concrete columns. The alternative proposed solution uses arched truss main girders and truss purlins. They are supported on existing concrete columns. All load bearing members of existing and new design structure – main girders, purlins, roof bracing - have been evaluated according to actual normative rules. It is evident that the static assessment of the existing structure is satisfied from viewpoint of ultimate and serviceability limit states. The static assessment of the new structure is satisfied from the viewpoint of both limit states.
Family house load-bearing structure composed of thin-walled steel members
Bulíček, Radek ; Melcher,, Jindřich (referee) ; Karmazínová, Marcela (advisor)
The aim of the bachelor thesis is to design and verify load bearing members of single-storey family house composed of thin-walled cold-formed elements. Parking space for cars of timber members is the part of the house, too. The family house is in rectangular plan with dimensions of 9.5 x 10.5 m. The roof of the house is hipped, on the side of the house with the parking place rafters are associated with garage rafters. The following elements were statically assessed: structural members of the house roof (rafters, collar tie, roof bracing), structural members of the ceiling (ceiling beams), reinforcing timber frame, external and internal load bearing walls (columns), load bearing elements of the parking space (rafters, purlins, columns). All assessments were performed according to currently valid standards. The calculation showed that the resistance and serviceability of all components are satisfied.
Static verification and variant design of roof structure of winter sport stadium in Jihlava city
Bulíček, Radek ; Melcher, Jindřich (referee) ; Karmazínová, Marcela (advisor)
The aim of the thesis is the assessment of steel structure roofing winter stadium in Jihlava city and design of the variant solution of load bearing steel structure of the roof. The ground plan dimensions are 60 x 84 m The current structure is composite of truss main girders with parabolic lower chords, and purlins . Axial distances of main girders are 12 m and are supported on concrete columns. The alternative proposed solution uses arched truss main girders and truss purlins. They are supported on existing concrete columns. All load bearing members of existing and new design structure – main girders, purlins, roof bracing - have been evaluated according to actual normative rules. It is evident that the static assessment of the existing structure is satisfied from viewpoint of ultimate and serviceability limit states. The static assessment of the new structure is satisfied from the viewpoint of both limit states.
Family house load-bearing structure composed of thin-walled steel members
Bulíček, Radek ; Melcher,, Jindřich (referee) ; Karmazínová, Marcela (advisor)
The aim of the bachelor thesis is to design and verify load bearing members of single-storey family house composed of thin-walled cold-formed elements. Parking space for cars of timber members is the part of the house, too. The family house is in rectangular plan with dimensions of 9.5 x 10.5 m. The roof of the house is hipped, on the side of the house with the parking place rafters are associated with garage rafters. The following elements were statically assessed: structural members of the house roof (rafters, collar tie, roof bracing), structural members of the ceiling (ceiling beams), reinforcing timber frame, external and internal load bearing walls (columns), load bearing elements of the parking space (rafters, purlins, columns). All assessments were performed according to currently valid standards. The calculation showed that the resistance and serviceability of all components are satisfied.