Quantitative modelling of effect of transverse-axial tubular system on electrical activity of cardiac cells: development of model
Pásek, Michal ; Christé, G. ; Šimurda, J.
The transverse-axial tubular system (TAT-system) of cardiac muscle is a structure that allows rapid propagation of excitation into the cell interior. As suggested in many recent experimental works, it could have a significant effect on cardiac cell function induced by the accumulation or the depletion of ions in restricted tubular space. In our previous work [27], the basic properties of TAT-system were formulated and preliminary simulations characterizing its effect on cellular electrical activity realised. In this article, we describe the design of a more complex model of ventricular myocyte based mostly on data from guinea pig. The model integrates the description of electrical activity of surface and tubular membranes with the detailed description of mechanisms controlling the intracellular and tubular ion concentrations.
|
| |
| |
| |
| |
| |
| |
| |
| |
|
Iontově koncentrační změny v tubulárním systému srdečních komorových buněk potkana
Pásek, Michal ; Christé, G. ; Šimurda, J.
Práce prezentuje sestavení modelu srdeční komorové buňky potkana se zahrnutým transverzálně-axiálním tubulárním systémem a výsledky simulací charakterizující koncentrační změny tubulárních iontů při různé frekvenci stimulace buněk. Morfologie tubulárního systému a podíl iontových kanálů přítomných v tubulární membráně byly popsány v souladu s novými experimentálními údaji. Nárůst stimulační frekvence z 1 Hz do 5 Hz způsobil nárůst relativní deplece tubulárních iontů Ca2+ ze 7.3 % na 14 % a pokles relativní akumulace iontů K+ ze 4.3 % na 3 %.
|