National Repository of Grey Literature 8 records found  Search took 0.00 seconds. 
Extensible measurement socket placement optimalization with respect to the higher number of conductors
Šindler, Matěj ; Čepička, Martin (referee) ; Wasserbauer, Vojtěch (advisor)
In opening, this bachelor thesis is describing structure and basic block description of UniGear switchgear manufactured by ABB company. Then this thesis focus on current and voltage transformers and sensors often used in this type of switchgear. Main part of this thesis is dedicated to evolution and description of connector, used in connection solution of withdrawable metering unit with low-voltage compartment. Next part states the main requirements for new connector, that will replace current connector in future solution. In following part there is a list of different options for new connector with their biggest strengths and weaknesses pointed out. Then there is list of alternative placements for new connector. In final part is chosen and described new connector and its placement. This solution is valuated and backed up by created 3D models.
Comparison of Instrument Transformer and Sensor Applications in Feeder Terminal REF 542plus
Hrycík, Tomáš ; Majer, Karol (referee) ; Orságová, Jaroslava (advisor)
The aim of this Master´s thesis is use of instrument transformers and sensors on field of industry protection. We will compare current and voltage transformers, current sensor – based on Rogowski coil, voltage sensor – based on voltage divider. By this measure devices, we can monitoring values of analog quantities in medium voltage switchgear. It is impossible to compare, measure and analyze without this measure devices. There is protection terminal REF542plus, which can compile this values. The REF542plus ability are measuring, monitoring, remote control and protection. First, we will discuss about theory of sensors and convential instrument transformers and analysis of analog signal. We will compare analog input channel on sensor´s analog module and transformer´s analog module. There are few differences between type of analog modules. For analog signal analysis are important frequency filters and Analog/ Digital Convertor (sigma-delta). We will describe functions and options of REF542plus. In practical part of this project, we will test protection functions of protection terminal. First, protection terminal will be connected to sensors. Second protection terminal will be connected to transformers. For testing we chose Earth-fault directional protection and differential protection. We will make only secondary tests. That´s mean, input analog quantities to REF542plus will be simulated by tester. In all we will verify quality of protection. We will focus on lower settings of protection and we will inject protection by low current. Objectives are testing of trip characteristics and measuring of trip time.
Design of instrument transformers for digital protection relays
Souček, Jan ; Matuška, Marcel (referee) ; Toman, Petr (advisor)
Master’s thesis is concerned with instrument transformers, which are used in conjunction with numerical protection relays. Therefore mainly with protective transformers of class P and transformers dimensioned for transient effects, which are important e.g. for fast differential or distance protections. The introduction includes fundamental notions, quantities and equations, which refers to instrumental current and voltage transformers. Below are mentioned connection diagrams of these transformers applied to specific electrical network types and faults, of which identification is required. These diagrams and faults are supplied with math equations and eventually with phasor diagrams. Noted informations corresponds to the present standards. Task of the next part is to compile requirements for dimensioning of current transformers, which imposes digital protections from ABB, AREVA and Siemens companies. These requirements, which mostly defines the minimal accuracy limit factor or the knee-point voltage of current transformer, are specified for individual protection terminals, eventually for specific protective functions. Part of the thesis is computer program developed as macro in the Microsoft Office Excel program via Visual Basic for Applications programming language. Program uses equations noted in this work and it can be used for quick dimensioning of current transformers for protective terminals from manufactures mentioned above.
Instrument voltage transformers of outdoor type
Velešík, Petr ; Bušov, Bohuslav (referee) ; Vaněk, Jaromír (advisor)
The function analysis of instrument voltage transformer with the aid of his equivalent diagram and his phasor diagrams is main part of my masters thesis. I solve the influence and errors of his equivalent diagram’s elements on this instrument voltage transformer. Than I talk about suitable magnetic materials using for instrument voltage transformers. There are 3D pictures which show lay-out of instrument voltage transformers’s windings and his magnetic circuit.
Extensible measurement socket placement optimalization with respect to the higher number of conductors
Šindler, Matěj ; Čepička, Martin (referee) ; Wasserbauer, Vojtěch (advisor)
In opening, this bachelor thesis is describing structure and basic block description of UniGear switchgear manufactured by ABB company. Then this thesis focus on current and voltage transformers and sensors often used in this type of switchgear. Main part of this thesis is dedicated to evolution and description of connector, used in connection solution of withdrawable metering unit with low-voltage compartment. Next part states the main requirements for new connector, that will replace current connector in future solution. In following part there is a list of different options for new connector with their biggest strengths and weaknesses pointed out. Then there is list of alternative placements for new connector. In final part is chosen and described new connector and its placement. This solution is valuated and backed up by created 3D models.
Comparison of Instrument Transformer and Sensor Applications in Feeder Terminal REF 542plus
Hrycík, Tomáš ; Majer, Karol (referee) ; Orságová, Jaroslava (advisor)
The aim of this Master´s thesis is use of instrument transformers and sensors on field of industry protection. We will compare current and voltage transformers, current sensor – based on Rogowski coil, voltage sensor – based on voltage divider. By this measure devices, we can monitoring values of analog quantities in medium voltage switchgear. It is impossible to compare, measure and analyze without this measure devices. There is protection terminal REF542plus, which can compile this values. The REF542plus ability are measuring, monitoring, remote control and protection. First, we will discuss about theory of sensors and convential instrument transformers and analysis of analog signal. We will compare analog input channel on sensor´s analog module and transformer´s analog module. There are few differences between type of analog modules. For analog signal analysis are important frequency filters and Analog/ Digital Convertor (sigma-delta). We will describe functions and options of REF542plus. In practical part of this project, we will test protection functions of protection terminal. First, protection terminal will be connected to sensors. Second protection terminal will be connected to transformers. For testing we chose Earth-fault directional protection and differential protection. We will make only secondary tests. That´s mean, input analog quantities to REF542plus will be simulated by tester. In all we will verify quality of protection. We will focus on lower settings of protection and we will inject protection by low current. Objectives are testing of trip characteristics and measuring of trip time.
Design of instrument transformers for digital protection relays
Souček, Jan ; Matuška, Marcel (referee) ; Toman, Petr (advisor)
Master’s thesis is concerned with instrument transformers, which are used in conjunction with numerical protection relays. Therefore mainly with protective transformers of class P and transformers dimensioned for transient effects, which are important e.g. for fast differential or distance protections. The introduction includes fundamental notions, quantities and equations, which refers to instrumental current and voltage transformers. Below are mentioned connection diagrams of these transformers applied to specific electrical network types and faults, of which identification is required. These diagrams and faults are supplied with math equations and eventually with phasor diagrams. Noted informations corresponds to the present standards. Task of the next part is to compile requirements for dimensioning of current transformers, which imposes digital protections from ABB, AREVA and Siemens companies. These requirements, which mostly defines the minimal accuracy limit factor or the knee-point voltage of current transformer, are specified for individual protection terminals, eventually for specific protective functions. Part of the thesis is computer program developed as macro in the Microsoft Office Excel program via Visual Basic for Applications programming language. Program uses equations noted in this work and it can be used for quick dimensioning of current transformers for protective terminals from manufactures mentioned above.
Instrument voltage transformers of outdoor type
Velešík, Petr ; Bušov, Bohuslav (referee) ; Vaněk, Jaromír (advisor)
The function analysis of instrument voltage transformer with the aid of his equivalent diagram and his phasor diagrams is main part of my masters thesis. I solve the influence and errors of his equivalent diagram’s elements on this instrument voltage transformer. Than I talk about suitable magnetic materials using for instrument voltage transformers. There are 3D pictures which show lay-out of instrument voltage transformers’s windings and his magnetic circuit.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.