National Repository of Grey Literature 23 records found  1 - 10nextend  jump to record: Search took 0.01 seconds. 
Air conditioning in the library
Pospíšilová, Lucie ; Uher, Pavel (referee) ; Blasinski, Petr (advisor)
Dissertation offers a plan for air – conditioning equipment of library building in Brno and it involves air filter experimental measurement. The proposal is divided into three parts. The first part explains air filter theory with detailed description of atmospheric air filters for separation of particles for general ventilation - filter parameter determination. Theory part ends specifically with pocket air filters and their construction. The second part focuses on experimental pocket air filter measurement execution, which calculates with variable filter cartridges and pocket count. Measurement also evaluates pressure drop and their efficiency. The last part of the dissertation looks at air – conditioning equipment design for specified building, concretely library building. The project solves fresh air traffic into interior of selected library rooms and it counts with thermal heat gain in summer season, heat loss in winter season and air humidity modification.
Air conditioning in multifunctional center
Svobodová, Leona ; Blasinski, Petr (referee) ; Rubina, Aleš (advisor)
The object of this bachelor thesis is the design of air-conditioning equipment in a multifunctional centre. The devices serve a multifunctional hall and a room with over-head, the lighting and the sound. The units are designed in a way to meet all the hygienical, operational and functional requirements and to create optimal in-door microclimatic conditions for people to stay. There were used all the available budget calculations, applicable regulations and standards for this design. The air-conditioning provides a supply of fresh air and conducting of depreciated air, cov-erage of heat losses, removal of heat load and humidification of air. The theoreti-cal part deals with the system of return gaining of heat and describes advantages and disadvantages of every device enabling.
Aircondition of building with medical operation
Frčka, Lukáš ; Rubina, Aleš (referee) ; Rubinová, Olga (advisor)
This bachelor thesis is focused on a proposal of air-conditioning for operating rooms and hinterlands of adjacent clean spaces, clean corridors, rooms for patient preparation and cleaning etc. Air-conditioning units are designed according to functional, operational and hygienic requirements of microclimates of buildings. The theoretical part is focused on structural composition of air-conditioning units for spaces with high purity requirements. The calculation and project documentation part consist of designing three air conditioning devices for air-conditioning of operating rooms and adjacent clean spaces. The result of the thesis is detailed design and project documentation of these three devices.
Airconditioning in the clean space
Faltys, Michal ; Ell, Jiří (referee) ; Rubina, Aleš (advisor)
The bachelor´s thesis deals with the designing of air conditioning system for clean spaces of operating rooms and spaces which are necessary for assuring of operation these operating rooms. The system is proposed to meet hygienic, operational and functional requirements for indoor microclimate of clean spaces. The task of this system is the transport of fresh air to interior, the covering of the heat looses during the winter and the covering of heat gains in summer. The equipment is also designed for regulation of air humidity in the interior. The theoretical part devotes to the issue of air conditioning of clean spaces generally, calculating and project´s parts devote of the concrete concept of two air conditioning equipments for the serving of clean spaces in the specified building. The result of this work is the detailed design work of these equipments.
Variant solutions reconstruction of airconditioning systems in the laboratory
Faltys, Michal ; Andrys, Petr (referee) ; Rubina, Aleš (advisor)
The diploma thesis deals with the designing and assessment of two variants of the reconstruction of the air conditioning system for the half of 3rd floor laboratory building BioVendor – Laboratorní medicína a.s. company. The system is proposed to fulfil hygienic, operational, economic and functional requirements for indoor microclimate of laboratories. The task of this system is the transport of fresh air to interior and the covering of heat gains in summer. The equipment is also designed for the regulation of air humidity in the interior. The theoretical part deals with the application of heat penetration of solar radiation double glazed construction. Calculating and project part deals with the specific proposal of two variants of a new HVAC system-level studies of which the selected variant is developed as the project documentation. Experimental part is devoted to measuring of CO2 concentration in operationally similar laboratory. The result of this work is to evaluate the operational and economic impacts on the choice of technically feasible options and implementation documentation selected option. The benefit of the experiment is to verify sufficient air exchange to ensure the optimum concentration of carbon dioxide in laboratories.
Airconditioning in hospital
Minář, David ; Ell, Jiří (referee) ; Rubina, Aleš (advisor)
This bachelor thesis is focused on a proposal of air conditioning for clean spaces and their hinterlands, as well as for the hinterlands of laboratories, operating rooms, waiting rooms and X-rays. The devices are designed according to hygienic, operational and functional requirements of microclimates of buildings. The theoretical part deals with the issue of heat recovery systems. The calculation and the proposal part consist of three air conditioning devices for hot air heating and air conditioning of clean spaces and warm air ventilation of hinterlands of operating rooms, waiting rooms, X-rays, etc. The result of the thesis is detailed design of these devices.
Airconditioning for hospital facility
Odehnal, Michal ; Blasinski, Petr (referee) ; Rubinová, Olga (advisor)
Bachelor´s thesis describes a design of a ventilation system for hospital facility. In this thesis first ground floor and basement designed and implemented. The system is proposed to meet hygienic, operational and functional requirements for indoor microclimate of clean spaces. The task of ventilation system is the transport of fresh air to interior, the covering of the heat looses during the winter and the covering of heat gains in the summer. The system is also designed for regulation of air humidity. Theory part of dissertation deals with clean spaces with specialization on medical facilities.
Air-Conditioning in the hospital pavilion
Kops, Tomáš ; Blasinski, Petr (referee) ; Rubinová, Olga (advisor)
The aim of the bachelor thesis is to design and evaluate the air-conditioning system for the medical facility. The first and second above-ground floors are designed and designed to meet hygienic and operational conditions for medical facilities. The air-handling system provides fresh air into the interior, eliminating heat losses in the winter and heat gains in the summer.
Adiabatic air cooling
Silbernágl, Petr ; Blasinski, Petr (referee) ; Rubinová, Olga (advisor)
The diploma thesis deals deals with the designing and assessment of the two variants of cooling and humidifying the air in the production hall for cotton in Humpolec. The system is proposed to fulfil hygienic, operational, economic and functional requirements for indoor microclimate of the production hall. The task of this system is the transport of cooler air to interior and the covering of heat gains all year round. The equipment is also designed for the regulation of air humidity in the interior. The theoretical part is devoted to air humidification and air humidification device. Calculation of the project and then a specific proposal, two variants for air distribution level studies. Both variants are treated as project documentation. Experimental part is devoted to the measurement on the measuring path containing adiabatic humidifier in the laboratory. The benefit of the experiment is to verify the data from the manufacturer adiabatic humidifier which we can assess the practical use of the product.
Airconditioning of the exhibition space
Dokládalová, Tereza ; Jelínek, Ondřej (referee) ; Rubina, Aleš (advisor)
The point of this bachelor thesis is to design two air-conditioning units specifically made for assigned facility with exhibition purposes - archeopark. The units are designed in a way to accomplish operational, functional and hygienical requierements of indoor microclimate. The purpose of these units is to ventilate, cover the heat loss, elimination of heat load, humidification and dehumidification of air. Teoretical part of this thesis deals with indoor microclimate and its influence on a quality of life and also covers terms such as SBS, BRI, PMV and PPD.

National Repository of Grey Literature : 23 records found   1 - 10nextend  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.