National Repository of Grey Literature 4 records found  Search took 0.01 seconds. 
Analysis of 110 kV distribution network in the Otrokovice nodal area
Vachutka, Ondřej ; Kučera, Michal (referee) ; Ptáček, Michal (advisor)
Master's thesis deals with analysis of distribution network 110 kV in south Moravia area. Therefore it makes basic description of the scope EG.D, a.s. company, current state of the 110 kV electricity network and their development. The practical part of the master's thesis is focused on the transmission capacity of the 110 kV wiring and the voltage monitoring in the substation during winter network load. Simulations were constructed for analysis of network load for the years 2020, 2025, 2030 and 2035. Steady state was calculated for the normal state as well as for the emergency state (N-1). The analysis was created to ensure 110 kV distribution network in the nodal area Otrokovice during the failure of the entire 400/110 kV Otrokovice transformation station for the years 2025, 2030 and the design of a new 400/110 kV substation.
Analysis of the impacts of DS element failures on reliability indicators
Vachutka, Ondřej ; Hanuš, Radek (referee) ; Ptáček, Michal (advisor)
Bachelor's thesis deals with the impacts of distribution network element failures on reliability indicators. Therefore it makes basic description of the reliability, the reliability indicators or the regulation of continuity in distribution of electric power. It also presents main results of the identification and evaluation of individual 22 kV elements failures in distribution network of PREdistribuce, a. s. between 2011 to 2016.
Analysis of 110 kV distribution network in the Otrokovice nodal area
Vachutka, Ondřej ; Kučera, Michal (referee) ; Ptáček, Michal (advisor)
Master's thesis deals with analysis of distribution network 110 kV in south Moravia area. Therefore it makes basic description of the scope EG.D, a.s. company, current state of the 110 kV electricity network and their development. The practical part of the master's thesis is focused on the transmission capacity of the 110 kV wiring and the voltage monitoring in the substation during winter network load. Simulations were constructed for analysis of network load for the years 2020, 2025, 2030 and 2035. Steady state was calculated for the normal state as well as for the emergency state (N-1). The analysis was created to ensure 110 kV distribution network in the nodal area Otrokovice during the failure of the entire 400/110 kV Otrokovice transformation station for the years 2025, 2030 and the design of a new 400/110 kV substation.
Analysis of the impacts of DS element failures on reliability indicators
Vachutka, Ondřej ; Hanuš, Radek (referee) ; Ptáček, Michal (advisor)
Bachelor's thesis deals with the impacts of distribution network element failures on reliability indicators. Therefore it makes basic description of the reliability, the reliability indicators or the regulation of continuity in distribution of electric power. It also presents main results of the identification and evaluation of individual 22 kV elements failures in distribution network of PREdistribuce, a. s. between 2011 to 2016.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.