U-probe for the COMPASS Tokamak
Kovařík, Karel ; Ďuran, Ivan ; Stöckel, Jan ; Seidl, Jakub ; Šesták, David ; Brotánková, J. ; Spolaore, M. ; Martines, E. ; Vianello, N. ; Hidalgo, C. ; Pedrosa, M. A.
A complex electrostatic-magnetic probe diagnostics, baptized as 'U-probe', is being prepared for measurement of properties of the filamentary structures in the edge plasmas of COMPASS tokamak. Probe will be composed of two identical towers. Each tower will house 3 sets of 3D coils, balanced triple probe and six single Langmuir probes each. The design of the probe is based on that of U-probe used on reversed field pinch RFX-mod and our combined electromagnetic probe at TJ-II stellarator. This new COMPASS diagnostic will measure vorticity and longitudial electric current of the plasma filaments. Analysis of the properties and, particularly, the correlation between filament vorticity and its current is expected to shed light into physics of filamentary structures in the tokamak plasma edge. The simulation of the probe surface temperature evolution as a function of expected incident heat loads within the COMPASS edge plasmas is presented.
|
|
Atomic Beam Probe Diagnostic for COMPASS Tokamak
Háček, Pavel ; Weinzettl, Vladimír ; Stöckel, Jan ; Anda, G. ; Veres, G. ; Zoletnik, S. ; Berta, M.
The COMPASS tokamak has been re-installed in IPP Prague after its transport from Culham in UK. New diagnostic tools are under development to address the scientific program focused on H-mode and pedestal physics. Atomic Beam Probe (ABP) is an innovatory diagnostic for measurement of poloidal magnetic field and plasma current fluctuations in the plasma edge. It is planned to be an extension of the beam emission spectroscopy system by collecting the lithium ions stemming from beam ionization. In the first approximation, ionization is proportional to the local plasma density. The poloidal magnetic field moves the ions toroidally. Therefore, the two-dimensional poloidal-toroidal measurement of the ion current in the exit port reveals information on both the density and magnetic field profiles, thereby also on the edge current profile. This article reviews the concept of the ABP diagnostic and the status of its installation on the COMPASS tokamak.
|
|
Measurements of Ion Temperature in the Edge Plasma of the COMPASS Tokamak
Naydenkova, Diana ; Janky, Filip ; Weinzettl, Vladimír ; Stöckel, Jan ; Šesták, David ; Odstrčil, T. ; Ghosh, J. ; Gomes, R. ; Pereira, T.
The two-grating spectrometer, which has been developed for the ISTTOK tokamak, allows an estimation of the temporal evolution of both ion temperature and poloidal velocity of the edge plasma by analysis of Doppler-shifted and broadened CIII spectral lines at ~465nm. At the current phase of the COMPASS tokamak operation, the first measurements of ion temperature using the optical system based on the spectrometer were performed and first results are presented.
|
| |
| |
|
Status of Magnetic Diagnostics on COMPASS
Havlíček, J. ; Kudláček, O. ; Janky, F. ; Horáček, Jan ; Beňo, R. ; Valcárcel, D.F. ; Fixa, J. ; Brotánková, Jana ; Zajac, Jaromír ; Hron, Martin ; Pánek, Radomír ; Cahyna, Pavel
The COMPASS tokamak is in a test operation after its reinstallation in Institute of Plasma Physics AS CR in Prague (IPP Prague) in the year 2008. This operation consists of commissioning of various diagnostics and tokamak auxiliary systems. This paper presents current status of magnetic diagnostics after its refurbishment, used method of the calibration and shows examples of magnetic diagnostics utilization for plasma position reconstruction as well as for vertical hydraulic preload interlock system.
|
| |
|
Pohyb nabitých částic v perturbovaných magnetických polích tokamaku
Papřok, R. ; Krlín, Ladislav ; Cahyna, Pavel ; Riccardo, V.
V tomto článku popisujeme dva hamiltonovské přístupy – plný a driftový – pro popis nabitých částic (kupř. elektronů, D+) v magnetickém poli tokamaku. Používáme základní toroidální konfiguraci pole s překrývajícími se řetězci ostrovů vytvářejících magnetickou ergodickou vrstvu. Chceme použít tento aparát pro řešení dvou fyzikálních problémů Za prvé pro odhad generace elektrického pole v okrajovém plazmatu způsobeného přidáním „ergodických cívek“, které mohou sloužit jako mechanismus potlačení okrajových nestabilit (ELMů) a budou studovány na tokamaku COMPASS. Za druhé chceme tento aparát použít pro sledování vlivu na runaway elektrony (energie kolem 10 MeV) v přítomnosti magnetických polí generovaných korekčními cívkami (EFCC) instalovanými na tokamaku JET.
|
| |
|
Komunikační protokol pro kontrolu polohy a tvaru plazmatu tokamaku COMPASS
Janky, F. ; Horáček, Jan ; Pereira, T.V.
Tokamak Compass, který je reinstalován na ÚFP AV ČR v Praze, bude mít nový digitální systém pro kontrolu polohy a tvaru plazmatu. Vývoj komunikačního protokolu je nezbytný pro propojení energetických zařízení vyrobených společností ČKD a operátorem - člověkem nebo počítačem. Tato práce je zaměřena na vývoj tohoto komunikačního protokolu. Operátor může přes protokol poslat požadavek na informaci o stavu energetiky, časovou synchronizaci, počet chyb, atd. Přes komunikační protokol budou posílány i předdefinované proudy pro jednotlivé napěťové zdroje. V brzké budoucnosti bude tento systém nahrazen zpětnovazebním kontrolním systémem integrovaným v CODACu. (Sběr dat a komunikační systém)
|