Národní úložiště šedé literatury Nalezeno 5 záznamů.  Hledání trvalo 0.01 vteřin. 
LHC Abort Gap Monitor acquisition system
Pacner, Petr ; Vágnerová, Jitka (oponent) ; Kubíček, Michal (vedoucí práce)
The Beam Dump System of the LHC Large Hadron Collider is one of its critical systems. It is responsible for changing the trajectory of the beam towards the beam dump. For its functionality it uses an Abort Gap - a space with no particles within a beam structure. This gap is formed during the injection of the particles into the LHC. The injection is never ideal hence Abort Gap always contains some particles. Energy accumulated in the Abort Gap can cause various damages and so its amount has to be continuously estimated. This is the purpose of an Abort Gap Monitor. The currently deployed Abort Gap Monitor uses analog integrators to measure the particle population. This makes the instrument difficult to calibrate due to its hardware inaccuracies. To improve the system measurement versatility and reproducibility the effort is made to create an acquisition system with digital integration. This work aims to design, verify and implement the digital acquisition system. The digital acquisition system serves as one of the major parts of the new CERN SY-BI group Abort Gap Monitor. This document is split into four sections. The first briefly describes the structure of the Beam Dump System and the importance of the Abort Gap. The second section explains the principle of Abort Gap measurements and the data evaluation methodology. The third section describes the current system design and its issues. Then it focuses on the new Abort Gap Monitor topology followed by acquisition system development. The last section presents the simulations and measurements obtained with the new Abort Gap Monitor Acquisition System and discusses further development steps.
Modul diagnostiky radarové antény
Pacner, Petr ; Urbanec, Tomáš (oponent) ; Kubíček, Michal (vedoucí práce)
Poruchy, jako je zkrat nebo rozpojení, na elektrických vedeních mohou často ohrozit funkčnost celé aplikace. Tato práce se proto zabývá návrhem konceptu modulu pro identifikaci těchto poruch na koaxiálním vedení mezi přijímačem a anténou v radarových systémech, přičemž se zaměřuje na jejich lokalizaci. Cílem je z dostupných metodik vybrat vhodný způsob analýzy takových chyb a vytvořit demonstrační realizaci modulu, která bude sloužit k dalšímu vývoji. Obsahem je teorie týkající se základního rozdělení poruch vedení a principů často využívaných detekčních metod včetně uvedení jejich některých parametrů, výhod a úskalí, což je základem pro výběr metody. Vybraná metoda je analyzována pomocí simulací a na laboratorních přístrojích ovládaných počítačovými skripty. Na závěr je implementována na vývojovou platformu, na níž je provedeno měření vzorku vedení
LHC Abort Gap Monitor acquisition system
Pacner, Petr ; Vágnerová, Jitka (oponent) ; Kubíček, Michal (vedoucí práce)
The Beam Dump System of the LHC Large Hadron Collider is one of its critical systems. It is responsible for changing the trajectory of the beam towards the beam dump. For its functionality it uses an Abort Gap - a space with no particles within a beam structure. This gap is formed during the injection of the particles into the LHC. The injection is never ideal hence Abort Gap always contains some particles. Energy accumulated in the Abort Gap can cause various damages and so its amount has to be continuously estimated. This is the purpose of an Abort Gap Monitor. The currently deployed Abort Gap Monitor uses analog integrators to measure the particle population. This makes the instrument difficult to calibrate due to its hardware inaccuracies. To improve the system measurement versatility and reproducibility the effort is made to create an acquisition system with digital integration. This work aims to design, verify and implement the digital acquisition system. The digital acquisition system serves as one of the major parts of the new CERN SY-BI group Abort Gap Monitor. This document is split into four sections. The first briefly describes the structure of the Beam Dump System and the importance of the Abort Gap. The second section explains the principle of Abort Gap measurements and the data evaluation methodology. The third section describes the current system design and its issues. Then it focuses on the new Abort Gap Monitor topology followed by acquisition system development. The last section presents the simulations and measurements obtained with the new Abort Gap Monitor Acquisition System and discusses further development steps.
Radar Antenna Diagnostic Module
Pacner, Petr
Faults in the electrical wiring can cause fatal problems in particular application. Therefore various Fault Detection, Isolation and Recovery techniques have been developed, able to detect these faults. Such Defects may occure on a coaxial cable lines in radar systems between transmitter (receiver) and antenna. The aim of this paper is to present simulations of sequence time-domain reflectometry method. The results indicate suitability of this method for transmission lines terminated with radar antenna and capability of reliable soft faults detection (short and open circuit).
Modul diagnostiky radarové antény
Pacner, Petr ; Urbanec, Tomáš (oponent) ; Kubíček, Michal (vedoucí práce)
Poruchy, jako je zkrat nebo rozpojení, na elektrických vedeních mohou často ohrozit funkčnost celé aplikace. Tato práce se proto zabývá návrhem konceptu modulu pro identifikaci těchto poruch na koaxiálním vedení mezi přijímačem a anténou v radarových systémech, přičemž se zaměřuje na jejich lokalizaci. Cílem je z dostupných metodik vybrat vhodný způsob analýzy takových chyb a vytvořit demonstrační realizaci modulu, která bude sloužit k dalšímu vývoji. Obsahem je teorie týkající se základního rozdělení poruch vedení a principů často využívaných detekčních metod včetně uvedení jejich některých parametrů, výhod a úskalí, což je základem pro výběr metody. Vybraná metoda je analyzována pomocí simulací a na laboratorních přístrojích ovládaných počítačovými skripty. Na závěr je implementována na vývojovou platformu, na níž je provedeno měření vzorku vedení

Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.