Cast-in-place tank
Laurinyeczová, Erika ; Šiška, Radek (oponent) ; Strnad, Jiří (vedoucí práce)
The thesis deals with the analysis of a reinforced concrete digestate tank. The tank is built as a semi-underground construction. The roof is designed as a reinforced concrete dome, which is prestressed in a circular beam with prestressing cables - monostrands. The calculation of internal forces were performed by the software SCIA Engineer. The structure was assessed for the ultimate limit state and the ultimate serviceability state, in terms of watertightness for the width of cracks.
Ceiling concrete slab over the tank of sewage treatment plant
Laurinyeczová, Erika ; Šulák, Pavel (oponent) ; Strnad, Jiří (vedoucí práce)
The work deals with the analysis of a multi-field reinforced concrete slab, which is located above the chambers of a wastewater treatment plant. The slab is reinforced by a pair of mutually perpendicular ribs. The ribs are located under the support walls of the object, which is located above the slab. The aim of this work is to design and assess the slab for ultimate and serviceability limit state. The internal forces were determined on a spatial model of the joist slab using SCIA Engineer. At the same time, there was a manual calculation performed. Due to the asymmetric geometry of the slab, a comparison of the results and an assessment of the suitability or unsuitability of a simplified manual calculation for such a type of construction was performed.
Cast-in-place tank
Laurinyeczová, Erika ; Šiška, Radek (oponent) ; Strnad, Jiří (vedoucí práce)
The thesis deals with the analysis of a reinforced concrete digestate tank. The tank is built as a semi-underground construction. The roof is designed as a reinforced concrete dome, which is prestressed in a circular beam with prestressing cables - monostrands. The calculation of internal forces were performed by the software SCIA Engineer. The structure was assessed for the ultimate limit state and the ultimate serviceability state, in terms of watertightness for the width of cracks.
Ceiling concrete slab over the tank of sewage treatment plant
Laurinyeczová, Erika ; Šulák, Pavel (oponent) ; Strnad, Jiří (vedoucí práce)
The work deals with the analysis of a multi-field reinforced concrete slab, which is located above the chambers of a wastewater treatment plant. The slab is reinforced by a pair of mutually perpendicular ribs. The ribs are located under the support walls of the object, which is located above the slab. The aim of this work is to design and assess the slab for ultimate and serviceability limit state. The internal forces were determined on a spatial model of the joist slab using SCIA Engineer. At the same time, there was a manual calculation performed. Due to the asymmetric geometry of the slab, a comparison of the results and an assessment of the suitability or unsuitability of a simplified manual calculation for such a type of construction was performed.