National Repository of Grey Literature 14 records found  1 - 10next  jump to record: Search took 0.01 seconds. 
Design of an optomechanical module for laser-induced plasma imaging
Buday, Jakub ; Hrdlička, Aleš (referee) ; Pořízka, Pavel (advisor)
Laser-Induced Breakdown Spectroscopy (LIBS) is a method of analytical chemistry that provides a qualitative and quantitative analysis of a sample. The ablation process of a sample is fast and dynamic and the change of plasma in time and space is a question of a few microseconds. An examination that provides a good time and space resolution is necessary to understand better the physical processes. For this reason, the goal of this thesis is to design a basic optomechanic construction for this type of experiment. Furthermore, it is important to check the functionality of this design and to use it for a basic comparison between the spectroscopic and imaging data. Also, the time development of plasma will be observed under different experimental conditions. The goal of this thesis, in general, is to prove that the morphology of plasma is as it is described in available related literature.
Interconnection of Restricted Boltzmann machine method with statistical physics and its implementation in the processing of spectroscopic data
Vrábel, Jakub ; Hrdlička, Aleš (referee) ; Pořízka, Pavel (advisor)
Práca sa zaoberá spojeniami medzi štatistickou fyzikou a strojovým učením s dôrazom na základné princípy a ich dôsledky. Ďalej sa venuje obecným vlastnostiam spektroskopických dát a ich zohľadnení pri pokročilom spracovaní dát. Začiatok práce je venovaný odvodeniu partičnej sumy štatistického systému a štúdiu Isingovho modelu pomocou "mean field" prístupu. Následne, popri základnom úvode do strojového učenia, je ukázaná ekvivalencia medzi Isingovým modelom a Hopfieldovou sieťou - modelom strojového učenia. Na konci teoretickej časti je z Hopfieldovej siete odvodený model Restricted Boltzmann Machine (RBM). Vhodnosť použitia RBM na spracovanie spektroskopických dát je diskutovaná a preukázaná na znížení dimenzie týchto dát. Výsledky sú porovnané s bežne používanou Metódou Hlavných Komponent (PCA), spolu so zhodnotením prístupu a možnosťami ďalšieho zlepšovania.
Mechanism of atomization of selected hydride forming elements in an externally heated quartz tube atomizer and a dielectric barrier discharge atomizer
Juhászová, Lucie ; Kratzer, Jan (advisor) ; Hrdlička, Aleš (referee)
Atomization conditions for tin hydride in the planar dielectric barrier discharge (DBD) plasma atomizer were optimized with detection by atomic absorption spectrometry (AAS). The effects of apparatus arrangement such as the shape of a waveform function of the high voltage power supply source, DBD atomizer design as well as presence of a dryer tube filled with NaOH pellets to prevent residual aerosol and moisture transport into the DBD were investigated in detail. The optimal experimental setup consisted of a square wave high voltage power supply source coupled to a DBD with vapor-deposited electrodes in the presence of NaOH dryer upstream the DBD atomizer. Argon was found as the best discharge gas under a flow rate of 120 mL min-1 while the DBD optimum high voltage supply rate was 7 kV. A sensitivity of 0.05 s ng-1 Sn and a limit of detection of 1.1 ng mL-1 Sn were reached under optimized conditions. Optimization of the whole experimental setup resulted in 7-fold improvement of sensitivity compared to the original arrangement consisting of a sinusoidal source coupled to a DBD atomizer with glued electrodes in absence of the dryer. Keywords atomic absorption spectrometry, hydride generation, hydride atomization, quart tube atomizer, dielectric barrier discharge (DBD)
Miniature plasma DBD atomizer for AAS and AFS
Straka, Marek ; Kratzer, Jan (advisor) ; Hrdlička, Aleš (referee)
Five designs of dielectric barrier discharge (DBD) atomizers have been constructed and optimized employing arsane as a model analyte. The individual DBD designs differed from each other in the style of electrode attachment, electrode shape and area. An externally heated quartz tube atomizer and another DBD atomizer design that have been studied before were used as reference. All the atomizer designs studied including the reference atomizers were found compatible with detection by atomic absorption spectrometry (AAS) giving comparable sensitivity of 0.44 s ng-1 As and detection limit around 0.2 ng ml-1 As under optimum atomization conditions. However, significant differences in optimum operation conditions were found among the DBD designs in terms of the applied voltage depending strongly on the style of electrode attachment. The design with metal strip electrodes glued to a quartz body requires more than 14 kV to be operated. The design with sputtered electrodes of the same shape can reach the same sensitivity with 8.5 kV. Selected DBD designs have been proven to be compatible also with other spectrometric detectors such as atomic fluorescence spectrometry (AFS) reaching detection limit 0.05 ng ml-1 As or atomic emission spectrometry (AES) with detection limit of 30 ng ml-1 As showing the...
Approaches to signal correction and standardization in laser spectroscopy
Schiffer, Štěpán ; Hrdlička, Aleš (referee) ; Pořízka, Pavel (advisor)
The subject of this diploma thesis is the study of a sample position influence on results of an experiment in laser spectroscopy. The aim is to design an appropriate way for standardization of signal obtained at different conditions with the respect to its applicability for stand-off analysis. In the theoretical part of the diploma thesis there are the basics of LIBS method described together with the issues of stand-off experiment and both, basic and advanced approches for the processing and correction of obtained spectra. Also the experiment is designed here, which is used for the analysis of the sample inclination and distance influence on the detected signal. The choice of appropriate ways for the signal correction follows and their applicability and efficiency is then experimentally tested.
Comparison of quantification strategies in Laser-Induced Breakdown Spectroscopy
Hošek, Martin ; Hrdlička, Aleš (referee) ; Prochazka, David (advisor)
The aim of the submitted work is a comparison of methods of quantitative analysis used in laser-induced breakdown spectroscopy (LIBS). The principles of LIBS method are explained at first, followed by a research of the most often used methods of quantitative analysis. The next part provides their description enabling a better comprehension and an eventual use of the methods in practice. Finally, the chosen methods are used to process data from the real experiment and the results are compared.
Classification of metals by means of Laser-induced Breakdown Spectroscopy and chemometric methods
Képeš, Erik ; Hrdlička, Aleš (referee) ; Novotný, Jan (advisor)
Táto diplomová práca sa zaoberá klasifikáciou kovov pomocou spektroskopie laserom indukovanej plazmy (LIBS) a chemometrických metód. Práca poskytuje prehľad o štúdiách na danú tému. Sú vybrané tri široko používané chemometrické klasifikačné metódy: "Soft Independent Modeling of Class Analogy" (SIMCA), "Partial Least Squares Discriminant Analysis" (PLS-DA) a variácia umelých neurónových sietí (ANN), "Feedforward Multilayer Perceptron". Rôzne prístupy k prieskumovej analýze su tiež preskúmané. Metódy sú stručne opísané. Následne sú klasifikátory experimentálne porovnané.
Study of influence of toxical and nutritional elements on cell metabolism using combination of Raman spectroscopy and Laser-Induced breakdown spectroscopy
Mazura, Martin ; Hrdlička, Aleš (referee) ; Prochazka, David (advisor)
In this work on-line discrimination of six bacteria strains by means of the Multivariate discrimination analysis (MVDA) is presented. Principal components analysis (PCA) was selected as most suitable technique. Two analytical methods – Laser-Induced breakdown spectroscopy (LIBS) and Raman spectroscopy were equipped for chemical analysis of bacteria strains. In order to obtain the best possible bacteria strains differentiation, the data from both methods was analyzed in two ways separately and together. The data from both measurements was normalized separately and afterwards combined in one data frame for simultaneous analysis. This data frame contained information from both analytical methods. Moreover an influence of cultivation period for each bacteria strain was studied. It was determined that Raman spectroscopy is able to discriminate two bacteria strains and LIBS even four bacteria strains. Using combination of both methods the complete discrimination was achieved. From information of first principal component it was determined that most valuable information in LIBS data is not included in different elemental composition but rather in influence of matrix effect. Solely the LIBS was utilized for studying the effect of cultivation period. It was possible to observe transformation of four bacteria strains within 24 hours. Based on results of this work it is possible to assume that combination of Raman spectroscopy and LIBS, because of the complementary information, is suitable for fast discrimination of different bacteria species and strains. Moreover it was determined that LIBS is able to observe the transformation caused by cultivation period.
Using Laser-Induced Breakdown Spectroscopy (LIBS) for Material Analysis
Pořízka, Pavel ; Hrdlička, Aleš (referee) ; Pína,, Ladislav (referee) ; Kaiser, Jozef (advisor)
Tato doktorská práce je zaměřena na vývoj algoritmu ke zpracování dat naměřených zařízením pro spektrometrii laserem indukovaného plazmatu (angl. LIBS). Zařízení LIBS s tímto algoritmem by mělo být následně schopno provést třídění vzorků a kvantitativní analýzu analytu in-situ a v reálném čase. Celá experimentální část této práce byla provedena ve Spolkovém institutu pro materiálový výzku a testování (něm. BAM) v Berlíně, SRN, kde byl sestaven elementární LIBS systém. Souběžně s experimentílní prací byl vytvořen přehled literárních zdrojů s cílem podat ucelený pohled na problematiku chemometrických metod používaných k analýze LIBS měření. Použití chemometrických metod pro analýzu dat získaných pomocí LIBS měření je obecně doporučováno především tehdy, jsou-li analyzovány vzorky s komplexní matricí. Vývoj algoritmu byl zaměřen na kvantitativní analýzu a třídění vyvřelých hornin na základě měření pomocí LIBS aparatury. Sada vzorků naměřených použitím metody LIBS sestávala z certifikovaných referenčních materiálů a vzorků hornin shromážděných přímo na nalezištích mědi v Íránu. Vzorky z Íránu byly následně na místě roztříděny zkušeným geologem a množství mědi v daných vzorcích bylo změřeno na Univerzitě v Clausthalu, SRN. Výsledné kalibrační křivky byly silně nelineární, přestože byly sestaveny i z měření referenčních vzorků. Kalibrační křivku bylo možné rozložit na několik dílčích tak, že závislost intenzity měděné čáry na množství mědi se nacházela v jiném trendu pro jednotlivé druhy hornin. Rozdělení kalibrační křivky je zpravidla přisuzováno tzv. matričnímu jevu, který silně ovlivňuje měření metodou LIBS. Jinými slovy, pokud určujeme množství analytu ve vzorcích s různou matricí, je výsledná kalibrační křivka sestavená pouze z jedné proměnné (intenzity zvolené spektrální čáry analytu) nepřesná. Navíc, normalizace takto vytvořených kalibračních křivek k intenzitě spektrální čáry matrčního prvku nevedla k výraznému zlepšení linearity. Je obecně nemožné vybrat spektrální čáru jednoho matričního prvku pokud jsou analyzovány prvky s komplexním složením matric. Chemometrické metody, jmenovitě regrese hlavních komponent (angl. PCR) a regrese metodou nejmenších čtverců (angl. PLSR), byly použity v multivariační kvantitatvní analýze, tj. za použití více proměnných/spektrálních čar analytu a matričních prvků. Je potřeba brát v potaz, že PCR a PLSR mohou vyvážit matriční jev pouze do určité míry. Dále byly vzorky úspěšně roztříděny pomocí analýzy hlavních komponent (angl. PCA) a Kohonenových map na základě složení matričních prvků (v anglické literatuře se objevuje termín ‚spectral fingerprint‘) Na základě teorie a experimentálních měření byl navržen algoritmus pro spolehlivé třídění a kvantifikaci neznámých vzorků. Tato studie by měla přispět ke zpracování dat naměřených in-situ přístrojem pro dálkovou LIBS analýzu. Tento přístroj je v současnosti vyvíjen v Brně na Vysokém učení technickém. Toto zařízení bude nenahraditelné při kvantifikaci a klasifikaci vzorků pouze tehdy, pokud bude použito zároveň s chemometrickými metodami a knihovnami dat. Pro tyto účely byla již naměřena a testována část knihoven dat v zaměření na aplikaci metody LIBS do těžebního průmyslu.
Detection of heavy metals in liquids employing laser-induced breakdown spectroscopy
Skočovská, Katarína ; Hrdlička, Aleš (referee) ; Novotný, Jan (advisor)
The diploma thesis deals with the use of laser induced breakdown spectroscopy (LIBS) for detection of heavy metals traces, copper and lead, in aqueous solution of copper(II) sulphate pentahydrate and lead(II) ethanoate trihydrate. Results obtained by using single and double-pulse LIBS are compared. The theoretical section focuses on the issue of heavy metals and detection possibilities, describes the fundamental principle of LIBS technique and its modification for liquid analysis. The experimental section describes analyzed samples, the experimental apparatus, double-pulse technique, and method of spectral analysis. The moving breakdown model, which theoretically predicts optimal values of some experimental parameters, is explained briefly in section Optimalizácia. This model has been tested, however the results of experiments did not prove the theory. Furthermore, the experimental section reports the process and results of the optimization of all key measurement parameters and obtaining limits of detection from calibration curves.