Národní úložiště šedé literatury Nalezeno 50 záznamů.  začátekpředchozí21 - 30dalšíkonec  přejít na záznam: Hledání trvalo 0.00 vteřin. 
Choice of polymer samples geometry for measurement of elongational viscosity using ser universal testing platform
Filip, Petr ; Švrčinová, Petra
Generation of purely uniaxial elongational flow of polymer melts is very uneasy problem. It seems that each hitherto developed device for measurement of uniaxial elongational viscosity also produces - to some extent - a planar flow. During the last period there has been questioned - based on this reasoning - the applicability of a SER Universal Testing Platform and was recommended the range of rectangular dimensions of polymer samples for which measurements of uniaxial elongational viscosity is possible to take into account. The aim of this contribution consists in verification of invariantness of uniaxial elongational measurements using the SER Universal Testing Platform with respect to the dimensions of polymer samples applied. There is shown that for sufficiently broad region of admissible widths and thicknesses the results are identical. For these measurements there was used LDPE Escorene (Exxon, U.S.A.).
A note to the measurement of extensional viscosity using SER Universal Testing Platform with different shapes of polymer samples
Švrčinová, Petra ; Filip, Petr ; Kharlamov, Alexander
For polymer melts, with respect to their numerical simulations, there were recommended to apply polymer samples (rectangles) with a width not exceeding 8 mm and a thickness less than 0.4 mm. The aim of this contribution is to document - for material used (LDPE Escorene, Exxon, USA) - the invariantness of the elongational viscosity measured with respect to sample dimensions including its width and thickness. The width of the samples used consecutively attained 12.7, 11.0, 9.3, and 7.4 mm; the thickness also ranged across a sufficiently broad interval (0.3-1.1mm). Temperature was set to 180, 190, and 200oC. For the measurements there were used the SER Universal Testing Platform from the Xpansion Instruments; the model SER-HV-P01 was applied with a Physica MCR501 rotational rheometer host system. The results obtained justify usage of a 'classical' width 12.7 mm (1/2") more suitable for better manipulation with a sample, especially its fixing to both drums perpendicularly to the clamps.
Polyvinyl chloride catheters with repressed migration of plasticizers
Sedláček, T. ; Polášková, M. ; Kašpárková, V. ; Filip, Petr ; Sáha, P.
Impart flexibility and desired softness of polyvinylchloride (PVC) – one of the most widely used polymeric materials for medical device production – is achieved by addition of appropriate amount of plasticizer, usually di(2-ethylhexyl phthalate) (DEHP), into polymer matrix. DEHP is not chemically bonded to PVC and migrates to the surrounding media such as saliva, blood, plasma, or serum resulting in several toxic effects. Migration of DEHP can be significantly suppressed by embedding PVC into another polymer preventing its direct contact with surrounding liquid media. Coextruded TPU-PVC-TPU catheters were prepared with various thicknesses of TPU layers to evaluate its repressing effect on DEHP releasing. Releasing kinetic of DEPH from both three layered catheters and PVC catheters into the acetonitrile was observed in various time intervals and determined using reverse-phase liquid chromatographic technique.
A note to the tube theory
Kharlamov, Alexander ; Filip, Petr ; Švrčinová, Petra
The classical Doi-Edwards (DE) model represents a basic issue for tube theories. The model describes dynamics of polymer strands between entanglements and predicts stress in linear polymers. In this contribution there is considered the dynamics of the whole molecules within the same tube picture. When the molecule end-to-end vector is considered as a Hookean spring the damping function shows weaker thinning. The presented model describes one of the possible mechanisms leading to weaker damping exhibited by branched polymers.
Powder injection moulding of a ceramic part
Hausnerová, B. ; Marcaníková, L. ; Filip, Petr
The aim of the study is to optimize the production of alumina ceramic parts via Powder Injection Moulding (PIM) technology. As a case study fabric with main demand on surface-roughness tolerances has been selected with the potential of high production quantities for textile machines industry. The process is searched in terms of material tailoring, part design and dimensions, and processing conditions of injection moulding, debinding and sintering steps. Rheological, thermal and pressure-volume-temperature characteristics were measured in order to provide the reliable data for the simulation of injection moulding as well as thermal and thermogravimetric analyses have been carried out to attain non-porous final sintered products.
Určení objemového průtoku vazkoplastických kapalin mezikružím za pomoci aditivní metody
Filip, Petr ; David, Jiří
Je presentována aditivní metoda umožňující přímé určení axiálního objemového průtoku v koncentrickém mezikruží pro kapalinu, jejíž chování lze popsat mocninovým či Vočadlovým modelem. Je ukázáno, že průtok lze vyjádřit jako součet dílčích průtoků jednotlivými mezikružími tvořícími v součtu původní celé mezikruží.
Poznámka k reptační teorii
Kharlamov, Alexander ; Filip, Petr ; Švrčinová, Petra
Neuvažování IA aproximace v klasickém Doi-Edwardsově modelu způsobuje značné výpočetní potíže, nicméně některé tokové situace nemohou být modelovány pomocí této aproximace, kterou také nově presentovaný přístup nebere v potaz.
Měření elongační viskozity PE materiálů
Švrčinová, Petra ; Kharlamov, Alexander ; Filip, Petr
Je provedeno měření elongační viskozity vybraných polyetylénových materiálů a ukázána možnost zefektivnění klasického postupu.
Možné využití limitních případů axiálního toku mezikružím pro mocninové kapaliny
Filip, Petr ; David, Jiří
Příspěvek analyzuje možnosti využití řešení limitních případů některých vstupních parametrů v případě toku mocninové kapaliny mezikružím pro širší rozsah parametrů.
K měření elongační viskozity pomocí SER universal testing platform
Švrčinová, Petra ; Kharlamov, Alexander ; Filip, Petr
Cílem příspěvku je presentovat měření elongační viskozity polyethylénů pomozí tzv. SER Universal Testing Platform. Pozornost je věnována možnostem jak kontrolovat možné prověšování měřených vzorků a jak urychlit měření pro vybrané materiály s cíle eliminovat nástup možné degradace materiálu.

Národní úložiště šedé literatury : Nalezeno 50 záznamů.   začátekpředchozí21 - 30dalšíkonec  přejít na záznam:
Viz též: podobná jména autorů
4 Filip, Patrik
1 Filip, Pavel
Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.