Spray &Trap Method for Analysis of Residual Toxic Agents in Water
Vlčková, Lenka ; Podborský, Vladimír (referee) ; Brno), (VTÚO (advisor)
This work deals with verification of the analysis of precursors or degradation products of toxic compounds in the air and water through GC/MS by method of the thermal desorption or combination of methods "spray & trap" followed by the thermal desorption transfer the sample into the analyzer. Toxic compounds triethyl phosphate (TEP) and diisopropylmethyl phosphonate (DIMP) were choosen for the analysis. For choosen compounds has been optimized desorption time, for TEP 240 seconds and DIMP 210 seconds. Then the calibration curve was made for different concentrations of compounds DIMP and TEP. On the basis of these measurements was tested the possibility of determining the concentration of the compound in water sample using of method "spray & trap“. Thanks to the high solubility of compounds TEP and DIMP in water, higher boiling temperatures in comparison with boiling temperature of water, and extraction at room temperature, it was not possible to detect used compounds. Therefore, the analysis of compounds DIMP and TEP in the water by method "spray & trap“ seems inappropriate.
Spray &Trap Method for Analysis of Residual Toxic Agents in Water
Vlčková, Lenka ; Podborský, Vladimír (referee) ; Brno), (VTÚO (advisor)
This work deals with verification of the analysis of precursors or degradation products of toxic compounds in the air and water through GC/MS by method of the thermal desorption or combination of methods "spray & trap" followed by the thermal desorption transfer the sample into the analyzer. Toxic compounds triethyl phosphate (TEP) and diisopropylmethyl phosphonate (DIMP) were choosen for the analysis. For choosen compounds has been optimized desorption time, for TEP 240 seconds and DIMP 210 seconds. Then the calibration curve was made for different concentrations of compounds DIMP and TEP. On the basis of these measurements was tested the possibility of determining the concentration of the compound in water sample using of method "spray & trap“. Thanks to the high solubility of compounds TEP and DIMP in water, higher boiling temperatures in comparison with boiling temperature of water, and extraction at room temperature, it was not possible to detect used compounds. Therefore, the analysis of compounds DIMP and TEP in the water by method "spray & trap“ seems inappropriate.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.