National Repository of Grey Literature 2 records found  Search took 0.01 seconds. 
Methods of evaluation of microclimate conditions and light in students dormitory - comparison of new and old building
Cechel, Zbyszek ; Holcátová, Ivana (advisor) ; Dohnal, Karel (referee)
In my Bachelor Thesis I will deal with the evaluation of microclimatic conditions and artificial lighting in various rooms at two halls of residence. This evaluation concerns the following rooms: students' rooms, studies, halls, kitchens and bathrooms. Microclimate oriented measuring primarily includes ambient temperature, mean radiation temperature (globe temperature), air circulation rate and air humidity. I measured all these four parameters separately in each room. Upon the basis of these four main parameters and using a computer programme, I calculated other secondary microclimatic parameters which also participate in the overall microclimatic condition in a room and which must therefore by no means be disregarded. These particular parameters are stated below in the practical section as part of the individual evaluation of each measured room. The theoretical section of the Thesis also contains formulas which may be used for the calculation of the specific and exact value of a parameter which we may require by virtue of other data concerning or resulting from other microclimatic findings. In addition, I used the programme to calculate the recommended values (limits) of some of these parameters which should not be exceeded in any circumstances. In the event of their exceeding the set limits, the most...
Methods of evaluation of microclimate conditions and light in students dormitory - comparison of new and old building
Cechel, Zbyszek ; Holcátová, Ivana (advisor) ; Dohnal, Karel (referee)
In my Bachelor Thesis I will deal with the evaluation of microclimatic conditions and artificial lighting in various rooms at two halls of residence. This evaluation concerns the following rooms: students' rooms, studies, halls, kitchens and bathrooms. Microclimate oriented measuring primarily includes ambient temperature, mean radiation temperature (globe temperature), air circulation rate and air humidity. I measured all these four parameters separately in each room. Upon the basis of these four main parameters and using a computer programme, I calculated other secondary microclimatic parameters which also participate in the overall microclimatic condition in a room and which must therefore by no means be disregarded. These particular parameters are stated below in the practical section as part of the individual evaluation of each measured room. The theoretical section of the Thesis also contains formulas which may be used for the calculation of the specific and exact value of a parameter which we may require by virtue of other data concerning or resulting from other microclimatic findings. In addition, I used the programme to calculate the recommended values (limits) of some of these parameters which should not be exceeded in any circumstances. In the event of their exceeding the set limits, the most...

Interested in being notified about new results for this query?
Subscribe to the RSS feed.